Sponsored Content
Top Forums UNIX for Dummies Questions & Answers vol group - physical partition size Post 29798 by Kelam_Magnus on Friday 11th of October 2002 10:39:22 AM
Old 10-11-2002
I would never go above 256, I believe there some issues with this.

I have systems with oracle DBs that are striped 128K across 4 disks. You should be good with 64K or 128K. My DBs are between 200GB and 500GB.

Smilie
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

understanding logical partition, physical partition

hi, 1) is logical partition the same as physical partition except that one is physical and the other is logical? 2) then it must a one to one ratio? (3 Replies)
Discussion started by: yls177
3 Replies

2. HP-UX

determine the physical size of the hard disk

Hi is there a cmd in hpux 11 to determine the physical size of the hard disk. not bdf command. i have searched the other threads here but cant find an answer. thank you guys (4 Replies)
Discussion started by: hoffies
4 Replies

3. AIX

max size of a group in /etc/group

I have several AIX servers running 5.2. What is the default max size for a group in /etc/group? How do I change the default max size for a group to be unlimited (if possible)? Thanks (4 Replies)
Discussion started by: antalexi
4 Replies

4. HP-UX

Unmount and remove all Logical vol.Volume group and physical disk

Hi, Someone please help me with how i can unmount and remove all the files systems from a cluster. This is being shared by two servers that are active_standby. (3 Replies)
Discussion started by: joeli
3 Replies

5. IP Networking

IPMI - Get physical memory size

Hi, Does anybody know how to get the RAM size of a powerless server (OS off), with a network hardware management protocol like IPMI ??? Thx (0 Replies)
Discussion started by: sncr24
0 Replies

6. AIX

changing Physical Partition (PP)

Hi all, I am trying to replace an old 9gb hard disk for a 36gb hard drive on an AIX 4.3.2 system (can't update) I was thinking of doing this by doing a dd from the 9gb to the 36gb hard drive and then resize the Logical Volumes. However, lspv <36gb hard disk> gives me the folowing: #lrnt>... (4 Replies)
Discussion started by: eRJe
4 Replies

7. UNIX for Dummies Questions & Answers

Confusion Regarding Physical Volume,Volume Group,Logical Volume,Physical partition

Hi, I am new to unix. I am working on Red Hat Linux and side by side on AIX also. After reading the concepts of Storage, I am now really confused regarding the terminologies 1)Physical Volume 2)Volume Group 3)Logical Volume 4)Physical Partition Please help me to understand these concepts. (6 Replies)
Discussion started by: kashifsd17
6 Replies

8. Solaris

ZFS : Can arc size value exceed Physical RAM ?

Hi, kstat -p -m zfs -n arcstats -s size returns zfs:0:arcstats:size 8177310584 this values is approx (7.61 GB) but my Physical Memory size is only 6144 Megabytes. Can this happen ? if yes, then how can I find free memory on the system. BTW, I ran the kstat commands from a Non... (2 Replies)
Discussion started by: sapre_amit
2 Replies

9. UNIX for Advanced & Expert Users

Physical disk IO size smaller than fragment block filesystem size ?

Hello, in one default UFS filesystem we have 8K block size (bsize) and 1K fragmentsize (fsize). At this scenary I thought all "FileSytem IO" will be 8K (or greater) but never smaller than the fragment size (1K). If a UFS fragment/blocksize is allwasy several ADJACENTS sectors on disk (in a ... (4 Replies)
Discussion started by: rarino2
4 Replies

10. AIX

Trouble removing Physical Disk from Volume Group

I want to remove hdisk1 from volume group diskpool_4 and migrate PV from hdisk1 to hdisk2 , but facing problems, so what is the quickest way to migratepv and remove hdisk1 -- # lspv | grep diskpool_4 hdisk1 00c7780e2e21ec86 diskpool_4 active hdisk2 ... (2 Replies)
Discussion started by: filosophizer
2 Replies
MD(4)							     Kernel Interfaces Manual							     MD(4)

NAME
md - Multiple Device driver aka Linux Software Raid SYNOPSIS
/dev/mdn /dev/md/n DESCRIPTION
The md driver provides virtual devices that are created from one or more independent underlying devices. This array of devices often con- tains redundancy, and hence the acronym RAID which stands for a Redundant Array of Independent Devices. md supports RAID levels 1 (mirroring) 4 (striped array with parity device) and 5 (striped array with distributed parity information). If a single underlying device fails while using one of these levels, the array will continue to function. md also supports a number of pseudo RAID (non-redundant) configurations including RAID0 (striped array), LINEAR (catenated array) and MUL- TIPATH (a set of different interfaces to the same device). MD SUPER BLOCK With the exception of Legacy Arrays described below, each device that is incorporated into an MD array has a super block written towards the end of the device. This superblock records information about the structure and state of the array so that the array can be reliably re-assembled after a shutdown. The superblock is 4K long and is written into a 64K aligned block that starts at least 64K and less than 128K from the end of the device (i.e. to get the address of the superblock round the size of the device down to a multiple of 64K and then subtract 64K). The available size of each device is the amount of space before the super block, so between 64K and 128K is lost when a device in incorporated into an MD array. The superblock contains, among other things: LEVEL The manner in which the devices are arranged into the array (linear, raid0, raid1, raid4, raid5, multipath). UUID a 128 bit Universally Unique Identifier that identifies the array that this device is part of. LEGACY ARRAYS Early versions of the md driver only supported Linear and Raid0 configurations and so did not use an MD superblock (as there is no state that needs to be recorded). While it is strongly recommended that all newly created arrays utilise a superblock to help ensure that they are assembled properly, the md driver still supports legacy linear and raid0 md arrays that do not have a superblock. LINEAR A linear array simply catenates the available space on each drive together to form one large virtual drive. One advantage of this arrangement over the more common RAID0 arrangement is that the array may be reconfigured at a later time with an extra drive and so the array is made bigger without disturbing the data that is on the array. However this cannot be done on a live array. RAID0 A RAID0 array (which has zero redundancy) is also known as a striped array. A RAID0 array is configured at creation with a Chunk Size which must be a power of two, and at least 4 kibibytes. The RAID0 driver assigns the first chunk of the array to the first device, the second chunk to the second device, and so on until all drives have been assigned one chunk. This collection of chunks forms a stripe. Further chunks are gathered into stripes in the same way which are assigned to the remaining space in the drives. If devices in the array are not all the same size, then once the smallest device has been exhausted, the RAID0 driver starts collecting chunks into smaller stripes that only span the drives which still have remaining space. RAID1 A RAID1 array is also known as a mirrored set (though mirrors tend to provide reflect images, which RAID1 does not) or a plex. Once initialised, each device in a RAID1 array contains exactly the same data. Changes are written to all devices in parallel. Data is read from any one device. The driver attempts to distribute read requests across all devices to maximise performance. All devices in a RAID1 array should be the same size. If they are not, then only the amount of space available on the smallest device is used. Any extra space on other devices is wasted. RAID4 A RAID4 array is like a RAID0 array with an extra device for storing parity. Unlike RAID0, RAID4 also requires that all stripes span all drives, so extra space on devices that are larger than the smallest is wasted. When any block in a RAID4 array is modified the parity block for that stripe (i.e. the block in the parity device at the same device offset as the stripe) is also modified so that the parity block always contains the "parity" for the whole stripe. i.e. its contents is equiva- lent to the result of performing an exclusive-or operation between all the data blocks in the stripe. This allows the array to continue to function if one device fails. The data that was on that device can be calculated as needed from the parity block and the other data blocks. RAID5 RAID5 is very similar to RAID4. The difference is that the parity blocks for each stripe, instead of being on a single device, are dis- tributed across all devices. This allows more parallelism when writing as two different block updates will quite possibly affect parity blocks on different devices so there is less contention. This also allows more parallelism when reading as read requests are distributed over all the devices in the array instead of all but one. MUTIPATH MULTIPATH is not really a RAID at all as there is only one real device in a MULTIPATH md array. However there are multiple access points (paths) to this device, and one of these paths might fail, so there are some similarities. A MULTIPATH array is composed of a number of logical different devices, often fibre channel interfaces, that all refer the the same real device. If one of these interfaces fails (e.g. due to cable problems), the multipath driver to attempt to redirect requests to another interface. UNCLEAN SHUTDOWN When changes are made to a RAID1, RAID4, or RAID5 array there is a possibility of inconsistency for short periods of time as each update requires are least two block to be written to different devices, and these writes probably wont happen at exactly the same time. Thus if a system with one of these arrays is shutdown in the middle of a write operation (e.g. due to power failure), the array may not be consis- tent. To handle this situation, the md driver marks an array as "dirty" before writing any data to it, and marks it as "clean" when the array is being disabled, e.g. at shutdown. If the md driver finds an array to be dirty at startup, it proceeds to correct any possibly inconsis- tency. For RAID1, this involves copying the contents of the first drive onto all other drives. For RAID4 or RAID5 this involves recalcu- lating the parity for each stripe and making sure that the parity block has the correct data. If a RAID4 or RAID5 array is degraded (missing one drive) when it is restarted after an unclean shutdown, it cannot recalculate parity, and so it is possible that data might be undetectably corrupted. The md driver currently does not alert the operator to this condition. It should probably fail to start an array in this condition without manual intervention. RECOVERY If the md driver detects any error on a device in a RAID1, RAID4, or RAID5 array, it immediately disables that device (marking it as faulty) and continues operation on the remaining devices. If there is a spare drive, the driver will start recreating on one of the spare drives the data what was on that failed drive, either by copying a working drive in a RAID1 configuration, or by doing calculations with the parity block on RAID4 and RAID5. While this recovery process is happening, the md driver will monitor accesses to the array and will slow down the rate of recovery if other activity is happening, so that normal access to the array will not be unduly affected. When no other activity is happening, the recovery process proceeds at full speed. The actual speed targets for the two different situations can be controlled by the speed_limit_min and speed_limit_max control files mentioned below. FILES
/proc/mdstat Contains information about the status of currently running array. /proc/sys/dev/raid/speed_limit_min A readable and writable file that reflects the current goal rebuild speed for times when non-rebuild activity is current on an array. The speed is in Kibibytes per second, and is a per-device rate, not a per-array rate (which means that an array with more disc will shuffle more data for a given speed). The default is 100. /proc/sys/dev/raid/speed_limit_max A readable and writable file that reflects the current goal rebuild speed for times when no non-rebuild activity is current on an array. The default is 100,000. SEE ALSO
mdadm(8), mkraid(8). MD(4)
All times are GMT -4. The time now is 04:11 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy