Sponsored Content
Full Discussion: multiple disk in sun os
Top Forums UNIX for Dummies Questions & Answers multiple disk in sun os Post 24834 by RTM on Thursday 18th of July 2002 09:17:39 AM
Old 07-18-2002
It is included with the OS (I think since 2.6). It's very good for mirroring the OS but is not very good for use on data drives for databases - for database drives, Veritas is much better (but it cost $$$).
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Clone disk for Sun Blade 2000

Hai ......... my name Rio, I want to clone my harddisk at Sun Balade 2000 server with Solaris 8 OS, my question is : a. what kind method for making backup or clonning disk ? b. what method more easier , quick but still reliable ? c. how to proceed it ? Thanks (1 Reply)
Discussion started by: rioria
1 Replies

3. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

4. Solaris

Sun Blade 100 Disk Compatibility

It's me again, I was taking my Sun Blade 100 apart last night to see what kind of drive I have. It is a Seagate ST320011A Barracuda ATA IV 20 GB 7200 RPM Ultra ATA/100 IDE. Now 20 gig ain't all that big anymore and I got to thinking about putting a couple bigger drives in there. although I... (7 Replies)
Discussion started by: BrewDudeBob
7 Replies

5. Solaris

Add new disk to Sun StorEdge 3310 RAID

HI guys. Bit of a noob so bear with me. I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies

6. Emergency UNIX and Linux Support

disk replacment, SUN M3000

we have a SUN M3000 server. setup as only 1 domain. disk c0t0d0 and c0t1d0 and setup as SVM mirrors. a few days ago disk T1 failed. new we have replaced the disk, but can's see the disk in format. have done cfgadm and devfsadm. still can't access the new disk in format. the output... (6 Replies)
Discussion started by: robsonde
6 Replies

7. Solaris

Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue. We have 2 LDOM configured on this server and this server running on single disk. #... (8 Replies)
Discussion started by: rock123
8 Replies

8. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies
MLXCONTROL(8)						    BSD System Manager's Manual 					     MLXCONTROL(8)

NAME
mlxcontrol -- Mylex DAC-family RAID management utility SYNOPSIS
mlxcontrol <command> [args] mlxcontrol status [-qv] [drive] mlxcontrol rescan controller [controller ...] mlxcontrol detach drive [drive ...] mlxcontrol detach -a mlxcontrol check drive mlxcontrol config controller mlxcontrol help command DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver. Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the unit number of the drive. Do not specify the path to a device node. status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives, otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa- tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives are critical and 2 if one or more are offline. rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver initialisation). If the -a flag is supplied, rescan all controllers in the system. detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the -a flag is supplied, detach all system drives from the nominated controller. check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the check. rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild. config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system drives from a configuration in a future release. help Print usage information for command. AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>. BUGS
The config command does not yet support modifying system drive configuration. Error log extraction is not yet supported. BSD
April 10, 2000 BSD
All times are GMT -4. The time now is 04:02 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy