03-07-2006
environment variable not set? *shrugs*
is AIO turned on? don't know if it needs to be, though. also don't recall if it requires a reboot if you change the setting... i THINK in AIX 5 you won't need to reboot... but don't quote me on that.
10 More Discussions You Might Find Interesting
1. Programming
Undefined first referenced
symbol in file
std::basic_ostream<char, std::char_traits<char> >::operator<<(int)/var/tmp//ccTR
std::cerr /var/tmp//ccTRcjui.o
std::cout /var/tmp//ccTRcjui.o... (1 Reply)
Discussion started by: suhasini
1 Replies
2. Programming
Hey everyone, I can't figure out this symbol referencing error after looking at it for the longest time, and I figured some fresh eyes might be able to point something out I am overlooking.
Undefined first referenced
symbol in... (1 Reply)
Discussion started by: fromatz
1 Replies
3. AIX
Hi
I have compiled a binary on AIX 5.3.0.0
but when i run i get following error
Could not load program ACE_wrappers/bin/gperf:
Symbol resolution failed for ../../../lib/libc.a(posix_aio.o) because:
Symbol _posix_kaio_rdwr (number 2) is not exported from dependent
module... (0 Replies)
Discussion started by: khan_nayeem
0 Replies
4. Solaris
Hi all,
I am getting the below error on Solaris sunfire v245 server
Error: can not display this video mode
optimum resolution 1024x768 60Hz
i am not able to resolve this .plz help me out ? (1 Reply)
Discussion started by: saurabh84g
1 Replies
5. HP-UX
Hi All,
I have a code which is used for conversion from binary to ASCII.
This code works absolutely fine on Linux and Solaris
And the same is giving many errors and warnings on HPUX. The machine on which i am compliing is "HP-UX kautilya B.11.11 U 9000/800 876920620 unlimited-user license"
... (10 Replies)
Discussion started by: junaid.nehvi
10 Replies
6. UNIX for Dummies Questions & Answers
Hi! I'm very new to unix, so please keep that in mind with the level of language used if you choose to help :D Thanks!
When attempting to use sudo on and AIX machine with oslevel 5.1.0.0, I get the following error:
exec(): 0509-036 Cannot load program sudo because of the following errors:... (1 Reply)
Discussion started by: Chloe123
1 Replies
7. Solaris
deleteing post (0 Replies)
Discussion started by: dshakey
0 Replies
8. Solaris
Hi,
i got the following error when i tried to access the cygwin x server from a windows XP PC.
"xdmcp fatal error session failed session 23 failed for display"
Alternatively, when i tried to access the same Cygwin X Server from another windows XP PC which is on a different LAN... (3 Replies)
Discussion started by: HarishKumarM
3 Replies
9. AIX
Hi,
I am installing bison-2.4.3 on AIX.
I am facing the below error.
Could not load program gawk:
Symbol resolution failed for gawk because:
Symbol __pthread (number 159) is not exported from dependent module /usr/lib/libpthreads.a(shr_xpg5.o).
Symbol libintl_bindtextdomain (number... (5 Replies)
Discussion started by: susmitha_m
5 Replies
10. Programming
I have a C code which i am trying to compile using gcc. When i am trying to compile it i get the error undefined symbol error though i am providing the -l*** option where *** refers to the module where the object files for those symbols are present.
Can someone help me on the same. (4 Replies)
Discussion started by: manaankit
4 Replies
REBOOT(2) System Calls Manual REBOOT(2)
NAME
reboot - close down the system or reboot
SYNTAX
#define _MINIX_SOURCE 1
#include <unistd.h>
int reboot(int how, ...)
DESCRIPTION
Reboot() is used to close down the system. It allows several ways of shutting down depending on how:
reboot(RBT_HALT)
Halt the system and return to the monitor prompt.
reboot(RBT_REBOOT)
Reboot the system by letting the monitor execute the "boot" command.
reboot(RBT_PANIC)
Cause a system panic. This is not normally done from user mode, but by servers using the sys_abort() kernel call.
reboot(RBT_MONITOR, code, length)
Halt the system and let the monitor execute the given code of the given length. (code is of type char * and length of type size_t.)
reboot(RBT_RESET)
Reboot the system with a hardware reset.
Reboot() may only be executed by the super-user.
DIAGNOSTICS
If the call succeeds, it never returns. If something went wrong, the return value is -1 and an error is indicated by errno.
SEE ALSO
shutdown(8), reboot(8), halt(8), sync(1).
NOTES
Minix can not return to the monitor if running in real mode, or if started from MS-DOS. This means that most of the reboot functions will
change to a reset.
AUTHOR
Edvard Tuinder (v892231@si.hhs.NL)
REBOOT(2)