Sun Storage Tek 2540 M2 controller lockdown


 
Thread Tools Search this Thread
Top Forums UNIX for Advanced & Expert Users Sun Storage Tek 2540 M2 controller lockdown
# 1  
Old 10-18-2016
Wrench Sun Storage Tek 2540 M2 controller lockdown

hello all,

I have recently acquired the above server and i am having issues with the RAID controllers being put into a lockdown state.
This occurs when new drives are added to the array, the controller automagically reboots and then gives status codes OE and LT. After this i am unable to communicate at all with the controllers.

So far i have connected to the arrays successfully using CAM with no drives in, but when the drives are added CAM loses communication with the array/controllers.

If anyone has any experience with these arrays, is there a preferred method of installing HDD's into the array, or is there any way to remove the lockdown state from the controller?

Any help wold be greatly appreciated Smilie
Login or Register to Ask a Question

Previous Thread | Next Thread

3 More Discussions You Might Find Interesting

1. Red Hat

Sun Storage Tek 6140 compatible with RHEL5.7?

Issue Description: ================ There are of 4 servers (SunFire X440) : siman7tdw: SunFire X440 (affected server) siman8tdw:SunFire X440 (affected server) siman9tdw:SunFire X440 siman10tdw:SunFire X440 Storage Server: Sun Storage Tek 6140 (Name: simantdw_disk_bak) and Sun Storage... (1 Reply)
Discussion started by: Pawan Kumar
1 Replies

2. AIX

DS 4700 Storage Controller

We have 2 controllers in storage controller A is working, configured in Storage Controller B is not configured in Storage, but Power supply is connected for controller B. my query is, for some reason if power goes down for Controller A, wheather it will be redundant using Controllers... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. Solaris

Sun StorageTek 2540 - shutdown matrix

Hi, I have a simple question on how to correctly disable the matrix? Looking for the Common Array Manager and I do not see this option... Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies
Login or Register to Ask a Question
ARCMSR(4)						   BSD Kernel Interfaces Manual 						 ARCMSR(4)

NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller SYNOPSIS
arcmsr* at pci? dev ? function ? DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation: - ARC-1110 PCI-X 4 Port SATA RAID Controller - ARC-1110ML PCI-X 4 Port SATA RAID Controller - ARC-1120 PCI-X 8 Port SATA RAID Controller - ARC-1120ML PCI-X 8 Port SATA RAID Controller - ARC-1130 PCI-X 12 Port SATA RAID Controller - ARC-1130ML PCI-X 12 Port SATA RAID Controller - ARC-1160 PCI-X 16 Port SATA RAID Controller - ARC-1160ML PCI-X 16 Port SATA RAID Controller - ARC-1170 PCI-X 24 Port SATA RAID Controller - ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller - ARC-1202 PCI Express 2 Port SATA RAID Controller - ARC-1210 PCI Express 4 Port SATA RAID Controller - ARC-1220 PCI Express 8 Port SATA RAID Controller - ARC-1230 PCI Express 12 Port SATA RAID Controller - ARC-1230ML PCI Express 12 Port SATA RAID Controller - ARC-1231ML PCI Express 12 Port SATA RAID Controller - ARC-1260 PCI Express 16 Port SATA RAID Controller - ARC-1260ML PCI Express 16 Port SATA RAID Controller - ARC-1261ML PCI Express 16 Port SATA RAID Controller - ARC-1280 PCI Express 24 Port SATA RAID Controller - ARC-1280ML PCI Express 24 Port SATA RAID Controller - ARC-1680 PCI Express 8 Port SAS RAID Controller - ARC-1680LP PCI Express 8 Port SAS RAID Controller - ARC-1680i PCI Express 8 Port SAS RAID Controller - ARC-1680x PCI Express 8 Port SAS RAID Controller - ARC-1681 PCI-X 8 Port SAS RAID Controller These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives. arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands. Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8). When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol- lowing command (once the initialization is finished): $ scsictl scsibus0 scan any any The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the bioctl(8) command. EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8) HISTORY
The arcmsr driver first appeared in NetBSD 5.0. AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines. BSD
March 3, 2008 BSD