12-25-2016
Does taking out the battery and waiting for some time (results in time/date reset) resets the ALOM ? I tried chassis serial (Sys S/N) doesn't work either.
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hi,
Anyone please tell me the default ALOM username and password for the sun server(Sun fire V210).
Thanks
muthu (1 Reply)
Discussion started by: muthulingaraja
1 Replies
2. Solaris
Every time I would try to send a break to my T2000 I would get this
Debugging requested; hardware watchdog suspended.
c)ontinue, s)ync, r)eset?
I couldn't get into OBP.
Here's what I found to do...
sc> bootmode
Bootmode: normal
sc> bootmode reset_nvram
sc> bootmode... (3 Replies)
Discussion started by: mediis
3 Replies
3. Solaris
Hi,
I have forgot the sc and console login password in sun v125 server,
can anyone suggest me how to reset sc password in sun v125 server.
Thanks
Rjs (3 Replies)
Discussion started by: rajasekg
3 Replies
4. Solaris
hallo anybody know how to set alom mail alerty server with yahoomail ?
thank u?where i can find mail server address for yahoomail?thank (1 Reply)
Discussion started by: yanto85
1 Replies
5. Solaris
Hi guys,
I'm in trouble with a Sunfire T2000.
The OS (Solaris10) is up and running, but I can't log in the sc>I think the terminal server is crashed!
Does anyone know if I can reset the sc> from the OS?
How can I do that?
Thx (6 Replies)
Discussion started by: cecco16
6 Replies
6. Solaris
Hi,
I was asked to connect a KVM screen to a Sun Fire V440 last night so I connected it up but no joy and nothing on the KVM screen. I was told that a reboot may fix the problem so connected to the ALOM and rebooted. On the plus side, the KVM screen now works but I lost the ALOM connection.
... (0 Replies)
Discussion started by: jimmy54321
0 Replies
7. Solaris
Hi ,
How to reset ALOM/SC password for Solaris box Sun Fire T-200
Thanks (5 Replies)
Discussion started by: chetansingh23
5 Replies
8. Solaris
I have bought from eBay a second hand Sun Fire V210 server and I'm really stumped at the lack of complete instructions on how to connect to it.
I don't have a Windows machine, I've only got Ubuntu and OS X computers. None of them have an old RS-232 port on them either.
In saying that, I have... (12 Replies)
Discussion started by: danijeljames
12 Replies
9. Hardware
Hello.
I have a sun v245 and I have no hard drive for it yet but i would like to connect it to my home router by ethernet cable so I can use Alom remotely. Could someone please tell me how to set it up.
Thank You (1 Reply)
Discussion started by: SunV245
1 Replies
10. Solaris
Hi all,
I made some calculations and it seems that fans are working more than they supposed to keep the internals at the specified values. Is there a way to adjust this ?
I have 2 approaches ;
-from ALOM sc|ok prompt
-from Solaris 10
or
-from a HW Switch
I am pretty sure that... (5 Replies)
Discussion started by: y33t
5 Replies
ONEAC(8) NUT Manual ONEAC(8)
NAME
oneac - Driver for Oneac UPS equipment
NOTE
This man page only documents the hardware-specific features of the oneac driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
This driver supports various Oneac UPS families:
o EG (late 80s, early 90s, plug-in serial interface card)
o ON (early and mid-90s, plug-in serial interface card)
o OZ (mid-90s on, DB-25 std., interface slot)
o OB (early 2000's on, big cabinet, DB-25 std., interface slot)
If your UPS is equipped with the Basic Interface card, use the genericups(8) driver.
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file:
testtime=num
Change battery test time from the 2 minute default.
offdelay=num
Change shutdown delay time from 0 second default.
INSTANT COMMANDS
This driver supports the following Instant Commands. (See upscmd(8))
All UPS units
shutdown.return
Turn off the load possibly after a delay and return when power is back.
shutdown.stop
Stop a shutdown in progress.
shutdown.reboot
Shut down the load briefly while rebooting the UPS.
test.failure.start
Starts a 15 second long simulation of an input power failure.
test.battery.start.quick
Start a "quick" battery test. The default time is 2 minutes. This time can be set in the ups.conf file. See testime above.
test.battery.stop
Stops a battery test that is in progress.
All ON UPS units
reset.input.minmax
Reset the minimum and maximum input line voltage values seen since the last reset or power on.
Newer ON UPS units
test.panel.start
Start testing the UPS panel.
test.battery.start.deep
Start a "deep" battery test. This test runs the UPS until the low battery point and then returns to the AC line.
reset.input.minmax
Reset the minimum and maximum input line voltage values seen since the last reset or power on.
beeper.enable
Enable UPS beeper/buzzer.
beeper.disable
Disable UPS beeper/buzzer.
beeper.mute
Mutes the UPS beeper/buzzer for the current alarm condition(s).
WRITABLE VARIABLES
See upsrw(8) to see what variables are writable for the UPS.
Note
If your UPS supports writing battery.runtime.low, the new set value is to be entered in minutes (up to 99) but the reported value is
reported in seconds (set value * 60).
Note
If your UPS supports input.transfer.low and input.transfer.high, those values are used to create an allowable output range. The UPS
will do what it can to keep the output voltage value within the defined range (for example: tap change or switch to inverter).
AUTHOR
Bill Elliot <bill@wreassoc.com>, Eric Lawson <elawson@inficad.com>
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 ONEAC(8)