I checked with my other servers which were running fine they have the same output.
Also here are the results for ndd -get
I don't know if it helps but it's set to auto_neg with the 1000 speeds enabled.
I am trying to set an interface to 100/Full, but the command I use are getting rejected. I think it is the last argument, but I don't know how to find the correct values.
I am trying to use the following script, but change hme to le .
echo "Setting hme interface 1: 100mb/full-duplex..."
... (2 Replies)
Hi Guys,
I need help with ndd.
I was going through network FAQ but i have more questions then answers regarding ndd.
#ndd -set /dev/hme instance 0
#ndd -set /dev/hme adv_100fdx_cap 1
#ndd -set /dev/hme adv_100hdx_cap 0
#ndd -set /dev/hme adv_10fdx_cap 0
#ndd -set /dev/hme adv_10hdx_cap 0... (2 Replies)
Hello Gurus
I would like to know more about ndd commands related to ethernet(NIC) like how to set link_status, link_speed & link_mode as I know how to check these value. And I also would like to know how to make these setting permanents after reboot as I know that these setting will vanish... (5 Replies)
Hi,
I would like to know whether there is any config file that i can refer to for the result of 'ndd -get /dev/tcp tcp_time_wait_interval'?
When i man 'ndd', there is one statement which is -> Each driver chooses which parameters to make visible using ndd. Does it answering my question above... (3 Replies)
Solaris 10 server (SunOS 5.10 Generic_137137_09)
I have a services file configured in /etc in there windows clients connect to my server on port 6034-6037
when I do the following
netstat | grep TestServices
it pulls all the connections active for those ports
so right now I have 10 clients... (3 Replies)
Following command was set up in startup script on Solaris 8 servers - improved network transfers of files from one server to the another (doubled transfer speed).
ndd -set /dev/tcp tcp_host_param '10.140.20.10 sendspace 279600 recvspace 279600 timestamp 1'
Now they are getting a new server... (15 Replies)
Hello,
I recently upgraded our system from Solaris 8 to 10. It seems couple of binaries crashed in the new server Solaris 10. Before digging too much on it , from theory it sounds like any binary that is built on Solaris 8 (using gmake) is supposed to be compatible with Solaris 10 , right ?
... (1 Reply)
Hi,
I'm having issues with sendmail when I try to send host to host mail. I've had to change the "my official domain name" line to mycompany.com to get the mails through the external spam filter, when a mail was sent with hostname.mycompany.com it was blocked. I had to change the Dj macro... (0 Replies)
Hi,
Recently, I had to disable autoneg in one of my servers having ixgbe1 interface. While using below command I got "Permission denied" error:
ndd -set /dev/ixgbe1 adv_autoneg_cap 0
On investigating further I found that adv_autoneg_cap is showing as read-only parameter. Although it is... (1 Reply)
Discussion started by: rochitsharma
1 Replies
LEARN ABOUT OPENSOLARIS
scconf_transp_adap_ce
scconf_transp_adap_ce(1M) System Administration Commands scconf_transp_adap_ce(1M)NAME
scconf_transp_adap_ce - configure the ce Sun Ethernet transport adapter
DESCRIPTION
Note -
Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software
still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor-
mation about the object-oriented command set, see the Intro(1CL) man page.
You can configure ce adapters as cluster transport adapters. These adapters can be used with transport types dlpi. The ce adapter is VLAN
capable.
A ce adapter connects to a transport switch or to another ce adapter on a different node. In either case, the connection is made through a
transport cable.
When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are
asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique
for the switch.
The default is to set the port name to the node ID hosting the adapter at the other end of the cable.
There are no user configurable properties for cluster transport adapters of this type.
SEE ALSO Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ce(7D)Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ce(1M)