03-15-2013
I saw the page about dladm, but for some reasons, some of those sub-commands are not available on my server (i.e. rename-link, show-phys, ...)
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi !
Does anyone know how can i get information about my network interface ... if it works in half or full duplex mode !!
Thx in adivance !
Witt (4 Replies)
Discussion started by: witt
4 Replies
2. UNIX for Advanced & Expert Users
Hi all,
I'm using an HP Proliant server with double NIC and Debian 5 (Lenny) as its OS. I used link bonding on it for several years with no problem.
Today, (now only one interface connected to switch) the interface went down. I restarted networking service (/etc/init.d/networking restart) and... (7 Replies)
Discussion started by: mjdousti
7 Replies
3. Solaris
HI,
genunix: NOTICE: ce0: xcvr addr:0x01 - link up 100 Mbps half duplex
genunix: WARNING: ce0: fault detected external to device; service degraded
genunix: WARNING: ce0: xcvr addr:0x01 - link down
genunix: NOTICE: ce0: fault cleared external to device; service available
genunix: ... (4 Replies)
Discussion started by: sunnybee
4 Replies
4. Solaris
i need to configure a zone to use different interface (bge2) than global and have connected to completely different network switch & to use its own defaultrouter and hosts file .. is it possible ..if so ..how ?
Thanks (9 Replies)
Discussion started by: skamal4u
9 Replies
5. UNIX for Advanced & Expert Users
hi
I have a question,
eth0 : 192.168.2.10
eth1: 192.168. 2.11
subnet : 255.255.255.0
eth0 and eth1 plug same swich
I want communication between the two interface one host examp :
ping 192.168.2.10 -I eth1
ping 192.168.2.11 -I eth0
but not respons.. pls helme (3 Replies)
Discussion started by: sadosan83
3 Replies
6. UNIX and Linux Applications
Hi,
I'm a italian student. For my thesis I develop a gateway with protocol 6lowpan.
For that I must access to network interface to develope my personal stack based on standard 802.15.4.
Can you help me? I need an explanation for that. (0 Replies)
Discussion started by: berny88
0 Replies
7. IP Networking
Hello,
Please what's the difference between:
AND
Thank you so much (3 Replies)
Discussion started by: chercheur857
3 Replies
8. IP Networking
Hello,
Please, how can i create a network interface with a routable IP address on linux (ubuntu) ?
AND
How can i desactivate an interface?
Thank you so much for help. (1 Reply)
Discussion started by: chercheur857
1 Replies
9. Solaris
I've one Netra 240
After changing main board and system configuration card reader, Network is not accessible any more, Network interfaces are always UP and Running even when there is no cable connected to Network interfaces.
I tried to restart and plumb/unplumb with no luck.
ifconfig -a... (7 Replies)
Discussion started by: samer.odeh
7 Replies
10. UNIX for Dummies Questions & Answers
I have a RHEL 5 system with a bonded interface configure using only one network port (eth0). So I have config file for ifcfg-bond0 and ifcfg-eth. I'd like to configure eth5 to be the second SLAVE in the bond. My question is, after I modify ifcfg-eth5, can I add eth5 to the bond0 interface without... (1 Reply)
Discussion started by: westmoreland
1 Replies
PHYS(2) System Calls Manual PHYS(2)
NAME
phys - allow a process to access physical addresses (2BSD)
SYNOPSIS
phys(segreg, size, physaddr)
unsigned int segreg, size, physaddr;
DESCRIPTION
The argument segreg specifies a process virtual (data-space) address range of 8K bytes starting at virtual address segregx8K bytes. This
address range is mapped into physical address physaddrx64 bytes. Only the first sizex64 bytes of this mapping is addressable. If size is
zero, any previous mapping of this virtual address range is nullified. For example, the call
phys(7, 1, 0177775);
will map virtual addresses 0160000-0160077 into physical addresses 017777500-017777577. In particular, virtual address 0160060 is the
PDP-11 console located at physical address 017777560.
This call may only be executed by the super-user.
ERRORS
[EPERM] The process's effective user ID is not the super-user.
[EINVAL] Segreg is less than 0 or greater than 7.
[EINVAL] Size is less than 0 or greater than 128.
SEE ALSO
PDP-11 segmentation hardware
BUGS
On systems with ENABLE/34(tm) memory mapping boards, phys cannot be used to map in the I/O page.
This system call is very dangerous. It is not considered a permanent part of the system.
Phys is unique to the PDP-11 and 2BSD; its use is discouraged.
3rd Berkeley Distribution January 22, 1987 PHYS(2)