Sponsored Content
Full Discussion: SEA configuration
Operating Systems AIX SEA configuration Post 302774505 by hedou on Saturday 2nd of March 2013 08:03:30 AM
Old 03-02-2013
SEA configuration

i want configure a SEA over my vios ,
i have a message error :
Code:
Method error (/usr/lib/methods/cfgsea):                                         
Failed to configure SEA with return code 1 and SEA-specific error code 10:      
Detailed info: Setting real adapter ent1 in promiscuous mode failed with error 1

Since it is an IVE logical port, it is likely that this VIOS needs to be configured as the IVE physical port's promiscuous logical partition

Command did not complete.

"Run mkdev" was last subcommand run.
please help me

Moderator's Comments:
Mod Comment edit by bakunin: even if you didn't say it this is clearly AIX. I am going to transfer this thread over to the AIX board. Please note too, that we really meant it when we asked you to use CODE-tags. Thanks
 

6 More Discussions You Might Find Interesting

1. SuSE

sea application in SUSE

We are using sea application in SUSE linux 10, we are getting the below problem while launching the SEA Sea is stopped with the message ' sh: /home/pub/bin/awk: cannot execute binary file' in the log window. Anybody can help me in this issue Thanks in Advance (1 Reply)
Discussion started by: durgaprasadr13
1 Replies

2. AIX

VIOS SEA Creation

Hi Guys, I'm getting the below error while trying to create a SEA adapter in VIOS $ mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1 ... (4 Replies)
Discussion started by: kkeng808
4 Replies

3. AIX

SEA

Hi all, I set up the following configuration on my system: - An LPar with a virtual adapter, first one with a vlan id=703 and id port=13. - The first adapter have to connect to a VIOS in which i configured an SEA. So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Discussion started by: idro
0 Replies

4. AIX

VIO SEA Adapters

hi guys BTW pretty new to VIO I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8 # lsdev -Cc adapter | grep ent ent0 Available Logical Host Ethernet Port (lp-hea) ent1 Available Logical Host Ethernet Port (lp-hea) ent2 Available 04-20... (8 Replies)
Discussion started by: karlochacon
8 Replies

5. AIX

SEA to standby

hello, what will happen if i try to move sea of my 1 vio server to standby( using chdev command), when sea of other vio server is already in standby mode? (1 Reply)
Discussion started by: amvineeth
1 Replies

6. AIX

PowerVM SEA etherchannel performance ?

Hello, POWER7 machine. 4 x 1Gbit port ethernet adapter is dedicated to vios. 8023ad etherchannel is created using those 4 ports. Etherchannel adapter is shared to lpars using SEA. If I test network performance directly from vios partition (using iperf) I'm geting nice 4Gbit throughput. But if... (3 Replies)
Discussion started by: vilius
3 Replies
scconf_transp_adap_ce(1M)				  System Administration Commands				 scconf_transp_adap_ce(1M)

NAME
scconf_transp_adap_ce - configure the ce Sun Ethernet transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure ce adapters as cluster transport adapters. These adapters can be used with transport types dlpi. The ce adapter is VLAN capable. A ce adapter connects to a transport switch or to another ce adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ce(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ce(1M)
All times are GMT -4. The time now is 03:14 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy