Operating Systems AIX Mksysb for vio servers Post 302774257 by MichaelFelt on Friday 1st of March 2013 01:13:57 PM
Old 03-01-2013
The simple way to configure a VIOS to be a NIM client is to use the padmin command: remote_management.

Have your nim system configured for internet, and stable, as the two arguments you provide are the interface and the master name.

Code:
$ man remote_management
remote_management command

Purpose

       Enables the Virtual I/O Server to be remotely managed by an AIX  NIM
       (Network Installation Management) master.

Syntax

       To enable the Virtual I/O Server to be remotely managed by an AIX NIM
       master:

       remote_management [ -interface Interface ] Master

       To disable remote management:

       remote_management -disable

Description

       The remote_management command will setup the Virtual I/O Server to
       allow remote management from a NIM master. The Master parameter
       specifies the NIM master hostname. The Interface parameter specifies
       the network interface to be used to connect to the NIM master. If
       Interface is not specified, the default network interface used will be
       en0.

       The remote_management command utilizes the NIM service handler for
       client communication (nimsh), so the NIM master must be nimsh capable.

       Once remote management has been enabled on the Virtual I/O Server,
       typical NIM functions, such as update, backup, and reinstall, can be
       initiated from the NIM master.

Flags
       -disable
            Disables the Virtual I/O Server NIM client daemon.
       -interface
            Specifies which network interface to use. If no network interface
            is specified, interface en0 will be used.

Exit Status

       See Exit status for Virtual I/O Server commands

Or, you can switch to root using oem_setup_env
and fill in the dialog to
# smitty nim
Just remember to use the secure communication aka nimsh
Code:
---

Once the VIOS is a nim client you can perform a mksysb backup just like any other nim client.
Note: you do not update it as a normal AIX client.
 

10 More Discussions You Might Find Interesting

1. AIX

Restoring mksysb to vio lpar?

I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up. I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Discussion started by: scottsl
1 Replies

2. AIX

is it ok to run AIX mksysb script on vio servers?

Hi to all now we running mksysb to nim on aix servers. we are planning to take mksysb from vio servers. can we use the same script for vio servers. thanks (10 Replies)
Discussion started by: honeym210
10 Replies

3. AIX

Backup of VIO

I have a script running remotely using viosvrcmd command on hmc to back up the VIO servers. these are the steps involved 1. Mount the NFS directory on to the VIO server 2. run backupios command 3. un mount the directory I am stuck up in the 3rd step. I am not able to unmount the nfs... (6 Replies)
Discussion started by: balaji_prk
6 Replies

4. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

5. AIX

vio related

In a dual vio, how will u know one lpar is in which vio? (1 Reply)
Discussion started by: shobhan.murthy
1 Replies

6. AIX

sddpcm on vio

I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO. On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies

7. Red Hat

vio in linux

I am working in AIX. In a P series machine both aix and linux os can install.. specific command is there for aix to list out the vio servers details mapped in a frame(ie. lssrc "IBM.ManagementServer", like that..) is there any command is der to list out vio servers details in linux or how to find... (1 Reply)
Discussion started by: muralikrish
1 Replies

8. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

9. AIX

Problems with VIO O/S 2.2.3

I hope someone has experienced this problem before and can help. I have a P730 (8231-E2D) which is fitted with 8 IBM SAS disks on 2 separate SISSAS controllers. The disk type is ST9146853SS (Seagate SAS 146Gb). The problem occurs when I try to install the VIO server software at 2.2.3. It... (3 Replies)
Discussion started by: johnf
3 Replies

10. AIX

Reboot VIO - OK?

We've got two datacenters and in every datacenter 2 VIOs. The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPAR:wall: (4 Replies)
Discussion started by: DiViN3
4 Replies
roar_vs_connection_obj(3)				   RoarAudio Programmer's Manual				 roar_vs_connection_obj(3)

NAME
roar_vs_connection_obj, roar_vs_stream_obj, roar_vs_vio_obj - VS API interface for use of main API SYNOPSIS
#include <roaraudio.h> struct roar_connection * roar_vs_connection_obj(roar_vs_t * vss, int * error); struct roar_stream * roar_vs_stream_obj (roar_vs_t * vss, int * error); struct roar_vio_calls * roar_vs_vio_obj (roar_vs_t * vss, int * error); DESCRIPTION
Those functions return internal connection, stream and VIO object of the VS object. They are used to use the main API with a VS opened stream. roar_vs_connection_obj() returns the connection object used for the control connection to the server. roar_vs_stream_obj() returns the stream object storing information about the stream. roar_vs_vio_obj() returns the VIO object used to read data from or send data to the server. Returned objects are freed as soon as the VS object is closed. If the VS object was created using roar_vs_new_from_con(3) the connection is not closed by the VS object and stay valid after close until it is closed by the program or library. The VIO object MUST NOT be used while in buffered mode. PARAMETERS
vss The VS object to return internal objects from. error This is a pointer to a integer used to store the error value in case of error. This can be NULL if not used but it is very recom- mended to use this error value to report good error messages to the user. RETURN VALUE
On success these calls return the described object. On error, NULL is returned. EXAMPLES
FIXME SEE ALSO
roarvs(7), libroar(7), RoarAudio(7). RoarAudio May 2011 roar_vs_connection_obj(3)
All times are GMT -4. The time now is 05:06 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy