Thanks all! Really appreciate it! This does help! Yup I would be looking for a single CEC of a 570 if at all or if I can get the same functionality for less $ with a 520 or 550 then would prefer those. (However, at this time the single CEC's of 570's come priced cheaper and so teh original question...) For PowerVM looks like I'll need at least the Standard VET to create VIO's (I recall reading the Enterprise VET will allow for LPM but I don't need that in the foreseeable future). With the Standard I can create two VIO's which is something I would want to do. Most of the hardware out there that I see comes with a POD and a VET for those listed as APV.

> Secondly, if you are running virtualisation, are you happy to run a single VIO with IVM or do you also need to factor in an HMC. With the 570 you must use an HMC! The IVM isn't an option.
I'd be looking to get an HMC shortly after if not together. I'm thinking then even for a single CEC of a 570 I'd still need the HMC?

> If you have an HMC and a server and want to run dual VIO Servers then you need a split backplane in you server, with disks attached to both backplanes.
Yes, if I have a Standard VET then would want to run two VIO's. Thanks very much for that! When you say I need disks attached to both backplanes I'm thinking 2 disks per backplane then (4 total)? (Not sure if I'm making sense.)

Read somewhere that an MOD (CUoD Memory Activation Code) might not make much sense on the 520's and 550's but I'm not 100% sure here on this. If I don't have the MOD on any of the three types, 520, 550, 570, what features would I be missing? I'm thinking I'll need all three codes but I'm not 100% sure if paying for an MOD would make any significant difference in functionality.

> 200-240 volt AC
This would be a problem. I'll have to do a bit more digging on exactly what I would need to check if my HH would allow for this.

Up to a 4-way machine would be fine so any 3 of those would do. Please let me know on the above and thanks very much again!

Thanks, DH
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Help with IBM 550 and HMC settings

I'm a Solaris and Debian/SuSE weenie, and I need some help setting the IP address of the remote web interface on an IBM 550 I plugged the port labled HMC1 to the network. The "network" is really a small linksys router that I use to test internet configs, as I can change the settings at will... (0 Replies)
Discussion started by: System Shock
0 Replies

2. AIX

new IBM pseries and new disks

Hello Gurus, i'm quite new person in AIX world, actually i'm SAP consultant. But due to my job faced with AIX. Trying to configure new server for installation SAP. We have 4 disks one of them (hdisk3) has VG rootvg. How i can extend rootvg with another disk? i tried: # extendvg rootvg hdisk0... (2 Replies)
Discussion started by: sapbcer
2 Replies

3. Linux

Why does they use Linux on IBM pSeries

Anyone can help me answer the question. Why does they use Linux on IBM pSeries not AIX. I can't understand why, cause AIX is the best supporting from IBM pSeries. Tks you. (3 Replies)
Discussion started by: quan0509
3 Replies

4. AIX

p6 570 network for AIX LPAR

know how to do it. (3 Replies)
Discussion started by: rainbow_bean
3 Replies

5. AIX

IBM pSeries Power5 9111-285 1,9 GHz

Hi , I am planing to buy IBM pSeries Power5 9111-285 1,9 GHz but I am confused with few things. I would be happy if you could clear it up for me ? 1.Do I have to buy some license in order to create Lpars ? 2.Do I have to buy some license in order to use HMC , micro - partiocioning , VIOS... (4 Replies)
Discussion started by: phobus
4 Replies

6. Hardware

VT 520 Terminal

Back of a VT 520 Teminal has a 1"X1" (approx.) rectangular area covered by a removable plastic flap. It is just above the keyboard hole(mini 6 pin DIN). What is it? Thank you. ---------- Post updated at 02:49 PM ---------- Previous update was at 11:37 AM ---------- I've got the answer.... (0 Replies)
Discussion started by: vectrum
0 Replies

7. AIX

IBM Power Pseries Open Firmware boot / VIOS POWERVM VET CODE

Hello, I installed PowerVM IVM Virtual I/O on P-550 but later found out that the machine isn't activated for CoD VET code for virtualization. So when booted , it goes into OPEN Firmware I/O Hosting requires a hosting partition boot not permitted exit called > ok Panel shows > IO... (3 Replies)
Discussion started by: filosophizer
3 Replies

8. AIX

IBM QSECOFR password missing P/N 9405-520

How to remove or reset password QSECOFR from IBM iSeries AS/400 P/N 9405-520. Regards (2 Replies)
Discussion started by: mtbax7
2 Replies

9. AIX

IBM AIX console pseries

Hi, when I boot I get an E1DC error code. I've looked it up and it says that this error occurs during the firmware check. But the error is called "Dynamic Console Selection" . 1- Machine stopped at LCD led display = E1DC = CA00E1DC E1DC Dynamic console selection. (maybe cable or keyboard)... (3 Replies)
Discussion started by: filosophizer
3 Replies
cmdisklock(1m)															    cmdisklock(1m)

NAME
cmdisklock - manage Serviceguard cluster lock devices. SYNOPSIS
cmdisklock check path cmdisklock [-f] reset path DESCRIPTION
cmdisklock is a tool to check the current state of a Serviceguard cluster lock device. It can also be used to reset the state of the clus- ter lock device. The need to reset the cluster lock device state could arise if the cluster lock device is replaced or becomes corrupt. A cluster lock device can be either an HP-UX LVM cluster lock or a cluster lock LUN device. HP-UX LVM cluster locks exist only on a disk in an LVM volume group. Cluster lock LUNs exist only on disks dedicated to cluster lock. cmdisklock is useful for checking either type of cluster lock and for re-initializing cluster lock LUN devices after a failure or corruption. NOTE To restore an HP-UX LVM cluster lock, use vgcfgrestore. cmdisklock will fail until vgcfgrestore is run, and cmdisklock is unnecessary as long as vgcfgbackup was done after the cluster lock was initialized. See the Managing Serviceguard manual for details. The syntax of the path option depends on the type of lock. For HP-UX LVM cluster lock disks, the syntax is VG:PV (for example: /dev/vglock:/dev/dsk/c0t0d2). For cluster lock LUN disks, the path is the disk device path. For example, /dev/sdd1 (on Linux) or /dev/dsk/c0t1d2 (on HP-UX). Options cmdisklock supports the following options: check Check the current state of the cluster lock device and report the results. reset Reset (initialize) the state of the cluster lock device. This operation should only be performed on a cluster lock LUN device. For HP-UX LVM cluster lock, use vgcfgrestore as documented in the Managing Serviceguard manual. After performing a reset, a check can be used to verify that the lock is cleared. EXAMPLES
If the cluster lock LUN device becomes corrupted and the cluster is up, messages like the following will appear in syslog. Mar 15 12:20:41 usb cmdisklockd[17599]: WARNING: Cluster lock LUN /dev/dsk/c0t1d2 is corrupt: bad label. Until this situation is cor- rected, a single failure could cause all nodes in the cluster to crash. Mar 15 12:20:41 usb cmdisklockd[17599]: After ensuring that all active nodes in the cluster have logged this message, run 'cmdisklock reset /dev/dsk/c0t1d2' to repair Mar 15 12:20:41 usb cmdisklockd[17599]: Cluster lock disk /dev/dsk/c0t1d2 is inaccessible Once the above messages appear in syslog on all running nodes, the following command will re-initialize the cluster lock LUN: ucd:/> cmdisklock reset /dev/dsk/c0t1d2 WARNING: Cluster lock LUN /dev/dsk/c0t1d2 is corrupt: bad label. Until this situation is corrected, a single failure could cause all nodes in the cluster to crash. After ensuring that all active nodes in the cluster have logged this message, run 'cmdisklock reset /dev/dsk/c0t1d2' to repair /dev/dsk/c0t1d2 is inaccessible Resetting cluster lock device /dev/dsk/c0t1d2 Cluster lock reset completed /dev/dsk/c0t1d2 is accessible cleared After the lock is restored, a message like the following appears in syslog: Mar 15 12:23:11 usb cmdisklockd[17599]: Cluster lock disk /dev/dsk/c0t1d2 is accessible WARNINGS
CAUTION For cluster lock LUN, reset is a potentially destructive operation. While cmdisklock checks for known volume manager and file system use (overridden by -f), it does not validate that the device to be reset is actually used by any cluster. If -f is used on the wrong device file, loss of data may result. CAUTION Care should be taken when doing a reset when the cluster is active as there is a remote possibility that the cluster will partition right when this command is run and both nodes could end up thinking they have successfully acquired the lock. To avoid this situation, make sure cmcld has logged a message in syslog on all running nodes saying the device is inaccessble, before performing a reset. Note that it is safe to run cmdisklock when the cluster is down. RETURN VALUE
cmdisklock returns the following values: 0 Successful completion. 1 The disk is inaccessible or is not recognized as a cluster lock. AUTHOR
cmdisklock was developed by HP. SEE ALSO
cmapplyconf(1m), cmviewcl(1m), vgcfgbackup(1m), vgcfgrestore(1m) Requires Optional Serviceguard Software cmdisklock(1m)
All times are GMT -4. The time now is 09:45 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy