Adding robot and drives

 
Thread Tools Search this Thread
Special Forums Windows & DOS: Issues & Discussions Adding robot and drives
# 1  
Old 04-27-2011
Adding robot and drives

Hi All

Im running veritas netbackup 6.5.5, on MWindows 2003 master server.
Ive just added a Quantum PX500 with 2 drives, the problem im facing is that now under the storage unit tab on console all the storage unit types for NDMP have the new robot listed and not the original one. The set up i need is to have the old robot TLD0 listed.
Can anyone help, the robot and drives were added via Configure storage devices Wizard.. The original robot is a ADIC 500 8 drive library.
Login or Register to Ask a Question

Previous Thread | Next Thread

6 More Discussions You Might Find Interesting

1. Hardware

Arduino Robot Tank Project

Normally I'm not into kits, but I thought my wife would enjoy this one since she is a big fan of robots and droids on StarWars! We are done with the basic mechanical assembly and starting on the electronics assembly today. The robot's "brain" consists of three levels. The Arduino board, on... (5 Replies)
Discussion started by: Neo
5 Replies

2. Solaris

Adding new hard drives on Sun SPARC T5440 server with Solaris 10

I need to add two new hard drives of 300 GB capacity to a SunSPARC T5440 server. The server currently has two hard drives of 146 GB each. How do I add the new drives to the existing UFS? What are the procedures involved in setting this server with the new hard drives? I am very new to Solaris... (6 Replies)
Discussion started by: ramatnmcc
6 Replies

3. Solaris

Adding new tape drives

hi, i am using Solaris 8 on a sparc box and already have 4 tape drives in a backup libaray attached to my unix server. we have recently added 2 new tape drives to the libaray and now want to get unix to see them. have it working in windows. how do i scan for new hardware and add theses new... (5 Replies)
Discussion started by: dshakey
5 Replies

4. Solaris

Adding logical drives

Hello, I have checked in here as I dont have enough experience as Solaris Admin. My Solaris seems to boot ok on a HP Proliant DL380 G6 server The release is 5.10, the kernel ID is Generic_137138-09. It was installed after creating one logical drive type RAID1, size 300GB. Now 2 further... (2 Replies)
Discussion started by: fogarino
2 Replies

5. Filesystems, Disks and Memory

Help adding new hard drives

Folks; I just added 2 physical new hard drives to my SUSE server. My server is already running SUSE 10.3 version. Is there a command i can use to add the new space or even see if the system can sees them? (3 Replies)
Discussion started by: Katkota
3 Replies

6. Shell Programming and Scripting

how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX

hi how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX? thanks (0 Replies)
Discussion started by: nokia1100
0 Replies
Login or Register to Ask a Question
MLXCONTROL(8)						    BSD System Manager's Manual 					     MLXCONTROL(8)

NAME
mlxcontrol -- Mylex DAC-family RAID management utility SYNOPSIS
mlxcontrol <command> [args] mlxcontrol status [-qv] [drive] mlxcontrol rescan controller [controller ...] mlxcontrol detach drive [drive ...] mlxcontrol detach -a mlxcontrol check drive mlxcontrol config controller mlxcontrol help command DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver. Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the unit number of the drive. Do not specify the path to a device node. status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives, otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa- tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives are critical and 2 if one or more are offline. rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver initialisation). If the -a flag is supplied, rescan all controllers in the system. detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the -a flag is supplied, detach all system drives from the nominated controller. check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the check. rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild. config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system drives from a configuration in a future release. help Print usage information for command. AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>. BUGS
The config command does not yet support modifying system drive configuration. Error log extraction is not yet supported. BSD
April 10, 2000 BSD