Download patches using FTP client

 
Thread Tools Search this Thread
Special Forums Windows & DOS: Issues & Discussions Download patches using FTP client
# 1  
Old 05-21-2009
Download patches using FTP client

Hi all,

I want to download patches using any FTP client by connecting to updates.oracle.com site on windows platform.Please advice me on this.



I am using windows xp operating system


Thanks in advance
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

FTP File download

Hi, I have few files at FTP location and have written a script to download the same from ftp based on the sysdate - 1, however with the below code I am unable to download the files from FTP. x=`TZ=CST+24 date +%Y%m%d` mget Daily_BIH_$x_NEW.tar.gz can anyone please help me in... (10 Replies)
Discussion started by: rramkrishnas
10 Replies

2. AIX

List of Installed patches for AIX from given set of patches

I need to find out list of installed patches from given list of patches. I have tried using instfix -f <File containing list of patches> -i -c But I was not able to understand the output of this command. It was like below. bos.perf.tools: :0.0.0.0:?: bos.rte.libc: :0.0.0.0:?: ... (4 Replies)
Discussion started by: Saurabh Agrawal
4 Replies

3. HP-UX

Software assistant swa get does not download patches

Hi, I am having some issues setting up and using swa report and swa get. When I use "swa report -a SEC -a CRIT -x hp_id username -x hp_pw pword -x proxy=http://proxservername:8080" the report is generated, etc as expected. However when I execute "swa get -t /var/spool/sw/ -x... (1 Reply)
Discussion started by: seanm
1 Replies

4. Shell Programming and Scripting

Download data from ftp.

Dear all, I am beginner to shell scripting. I have to download more than 1k files from ftp site. link is below ftp://ftp.ncbi.nih.gov/genomes/Bacteria/ Earlier i was using wget url, for download but the problem is some times folder names get changed, i don't know how to move in directories... (4 Replies)
Discussion started by: admax
4 Replies

5. AIX

Where to download ldap.client lpp

Hello, I am trying to configure an AIX machina to authenticate against a Windows 2003 AD, and I am desesperately trying to find the ldap.client lpp in the internet. I am using AIX 5.3 and I don't have access to the DVD media, please help! Thankyou, Tiago (2 Replies)
Discussion started by: tiagoskid
2 Replies

6. UNIX for Dummies Questions & Answers

cURL Active FTP Download

Hello, I know this is probably a very silly question for most but how to do I force curl to do active FTP downloads? Thank you Dallas (2 Replies)
Discussion started by: Dallasbr
2 Replies

7. HP-UX

ftp download problem

from windows ftp tool even you are not root user you can delete root files (8 Replies)
Discussion started by: mkhsy
8 Replies

8. HP-UX

Ftp Download Problem

FROM WINDOWS , WHILE GETTING DATA FROM HP-UNIX SERVER USING FTP, I AM ABLE TO GET DATA ONLY LESS THAN 4GB FILE, PLZ HELP ME HOW TO GET MORE MORE THAN 4GB FILE. (4 Replies)
Discussion started by: niranjan
4 Replies

9. SuSE

When a FTP download is completed

I receive files by FTP in an input directory. Every 10 seconds a process checks if some new file has arrived to the input directory and then the process moves them to another directory to be read by a second process. The problem is that there is no way to know if the download has finished... (11 Replies)
Discussion started by: Javi
11 Replies
Login or Register to Ask a Question
pprosvc(1M)                                               System Administration Commands                                               pprosvc(1M)

NAME
pprosvc - automation service program for Patch Manager SYNOPSIS
/usr/sbin/pprosvc [-c config-name] [-d [-p patch-id [,patch-id...]]] [-h] [-i [-n] [-p patch-id [,patch-id...]]] [-l] DESCRIPTION
Note - This command is deprecated. Use the smpatch analyze, smpatch download, and smpatch update commands instead. See the smpatch(1M) man page. Use the pprosvc command to analyze a system to determine the list of appropriate patches, download the patches, and apply them. This com- mand invokes patch operations in response to a user request or at a scheduled time. You must run this command as superuser. The pprosvc command enables you to do the following: o Analyze the host system for appropriate patches based on an established configuration o Generate the list of appropriate patches o Download the patches to your host system from the Sun patch server o Apply the patches based on a patch policy Use the pprosvc -i command to analyze a system, download the appropriate patches, and apply them. If analysis determines that patches are needed, the pprosvc command downloads them and applies them. Specify other options to automate a subset of the patch management tasks. If you specify the -d option, your system is analyzed and the appropriate patches are downloaded to your system. If you specify the -l option, your system is analyzed and the appropriate patches are listed. The list of patches that is generated by the analysis is based on all of the available patches from the Sun patch server. No explicit information about your host system or its network configuration is transmitted to Sun. Only a request for the Sun patch set is transmitted. The patch set is scanned for patches that are appropriate for this host system, the results are displayed, and those patches are optionally downloaded. The -d, -i, and -l options are mutually exclusive. Use the -p option to specify the patches on which to operate. You can use the -p option with the -d and -i options. OPTIONS
The following options are supported: -c config-name Uses an alternate configuration for the current patch operation. Use the pprosetup command to create new configura- tions. A configuration named recommended is included. For more information, see ``Specifying Alternate Configurations'' in the pprosetup(1M) man page. Note - This feature is not supported by the smpatch command. -d Downloads the patches that are appropriate for this host system. The patches are downloaded to the designated down- load directory. This option generates a list of appropriate patches, as does the -l option. However, instead of just displaying the list of patches, the -d option displays and downloads the patches from the Sun patch server. The patches are down- loaded using a secure connection, and all patches are authenticated using digital signature technology. Only patches that are signed with a Sun digital signature are stored in your download directory. Note - Specifying this option is equivalent to running the smpatch download command. -h Displays information about the command-line options. -i Applies the patches based on the patch policy. This option analyzes your system to generate a list of appropriate patches. If analysis determines that patches are needed, the patches are downloaded and applied. If no patches are permitted to be applied in automatic mode (by running pprosetup -p none), this option is identical to specifying the -d option. If only standard patches are permitted to be applied in automatic mode (by running pprosetup -p standard), all standard patches are applied. Note - Specifying this option is equivalent to running the smpatch update command. -l Generates a list of the patches that are appropriate for this host system. Note - Specifying this option is equivalent to running the smpatch analyze command. -n Runs pprosvc in automatic mode. The command that the cron job specifies is pprosvc -i -n. To schedule patch opera- tions to run in automatic mode, see the pprosetup(1M) man page. In automatic mode, the patch administrator (specified by the -a option) receives email notifications that describe the patches you downloaded and applied, and any error events that occurred. Do not use this option on the command line. Standard patches do not require any special actions on the part of the user. Such patches can be applied by using the patchadd command (see the patchadd(1M) man page) and do not need the host system to reboot for the patch to take effect. All nonstandard patches are moved to the sequester directory if you use the -n option to run in automatic mode. If you run in manual mode, however, nonstandard patches that have properties that match the policy specified by ppros- etup -i are applied. The rest of the nonstandard patches are moved to the sequester directory. You can apply patches from this directory at a later time. Patches, whether standard or nonstandard, that depend on sequestered patches are not applied under any circumstances. Such patches are placed in the sequester directory. For any patch that is placed in the sequester directory, refer to the patch's README file to determine how to apply it to your system. Note - This feature is not supported by the smpatch command. -p [patch-id[,patch-id,.Designates the specific patches on which to operate. Use this option with the -d option or the -i option. The list of patch IDs must be separated by commas. The specified patches are adjusted to use the current versions based on the patch baseline. Patches that are required by the specified patches are added to the complete list of patches to be applied. Note - Specifying this option is equivalent to specifying the -i option to the smpatch analyze, smpatch download, and smpatch update commands. EXAMPLES
Example 1: Applying Specific Patches in Manual Mode # pprosvc -i -p 102893-01,106895-09,106527-05 Applies patches 102893-01, 106895-09, and 106527-05 to the local system in manual mode. Example 2: Analyzing a System and Downloading Appropriate Patches # pprosvc -i Performs an analysis of the current system and downloads the appropriate patches based on all the patches from the Sun patch server. The resulting list of patches can be very long. Example 3: Applying Patches From the Recommended Configuration # pprosvc -c recommended -i Uses the recommended configuration to perform an analysis of the current system and downloads the appropriate patches. Standard patches and those needed from the recommended configuration are applied to the system based on the established patch policy. For information about set- ting the patch policy for manual mode, see the description of the -i option on the pprosetup(1M) man page. ATTRIBUTES
See the attributes(5) man page for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWpprou | +-----------------------------+-----------------------------+ |Interface Stability |Obsolete | +-----------------------------+-----------------------------+ SEE ALSO
patchadd(1M), patchrm(1M), pprosetup(1M), smc(1M), smpatch(1M), attributes(5) SunOS 5.10 7 May 2004 pprosvc(1M)