hi,

system operation: unix sco 3.2.4
Kernel not rebuild, do not remove or update tcp/ip e3H0 driver.

messages:
cat:cannot open../sdevice.d/5
line:5.1 32 -1
fatal error:mdevice:wrong number of fields

idmaster:device do not exist in therefore can not be update
idinstall: cannot add driver master entry

thanks
 
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Linux

I need help rebuild ext3 filesystem

hi to all I wanted to edit a enigma2 image to my box .. the image is root.img .. Analysed then I have the picture and I have this: parted root.img WARNING: You are not superuser. Watch out for permissions. GNU Parted 2.2 Using /home/soft/Bureau/enigma2/root.img Welcome to GNU Parted! Type... (3 Replies)
Discussion started by: soft
3 Replies

2. Red Hat

redhat rebuild kernel

Hi expert, I goes to # pwd /usr/src/kernels/2.6.32-279.el6.x86_64 then I make bzImage I meet error # make CHK include/linux/version.h CHK include/linux/utsrelease.h SYMLINK include/asm -> include/asm-x86 make: *** No rule to make target `missing-syscalls'. Stop. make:... (1 Reply)
Discussion started by: yanglei_fage
1 Replies

3. BSD

rebuild the portsystem

hi Howto rebuild the whole portsystem on freeBSD? THX (3 Replies)
Discussion started by: ccc
3 Replies

4. Programming

Rebuild the Dev of a non UNIX kernel...

My name for this post may be a bit off but basically I would like to take go though the same proses that kernel developers went though to build other kernels that are based on UNIX such as Linux, And do it from scratch IE. starting with the base UNIX and building on to it. So I in theory could... (0 Replies)
Discussion started by: DevSer2279
0 Replies

5. UNIX for Advanced & Expert Users

Error wile rebuild the kernel

Hi!!! I installed the patch: DUV40F16-C0040500-10245-Manual-20010328 to avoid a reboot problem in my server, AlphaServer 4100 with Tru64 4.0F. When the patch instalation finished I rebuild the kernel like this: # duconfig -c ORACLE-TEST Start de rebuild and a few minutes after appear... (0 Replies)
Discussion started by: irasela
0 Replies

6. HP-UX

How to rebuild a new disk

Hi.... I newbee to this and wanted help on hpux11 system. Disk is being replaced and need to rebuild and what r the commands I need to perform after the disk is swapped :confused: Thanks! (1 Reply)
Discussion started by: catwomen
1 Replies

7. UNIX for Dummies Questions & Answers

Rebuild command

I want to convert a Microfocus Sequential file to a Line Sequential Variable file. The reason I want to do this is so that I can upload the file from a UNIX box to a PC as a text file. I know that there is a command called "rebuild" that will allow me to convert the files, but I can not get it to... (1 Reply)
Discussion started by: douknownam
1 Replies

8. UNIX for Advanced & Expert Users

best way to rebuild a kernel

i really have an issue with the otherwise outstading FreeBSD Handbook when it comes to kernel building. information on the proper steps to take is really confusing. i think that chapters 9 and 21 need to be combined to give a very concise format on how best to deal with kernel building/rebuidling... (1 Reply)
Discussion started by: xyyz
1 Replies

9. UNIX for Dummies Questions & Answers

Need to rebuild and install the kernel.

Trying to install some ide raid drivers (to add some more hdds) and the instrcutions have toled me to modify some code in the kernel folder in usr/src (this is mandrake linux 9 btw). I need to then rebuild the kernel, how do I do this? Is there some file that I bring up for a whole c project (the... (2 Replies)
Discussion started by: pudad
2 Replies

10. UNIX for Dummies Questions & Answers

Don't Know to Rebuild Linux Kernel(URGENT)

Hello. I'm installing Oracle8i on Red Hat Linux Server 7.0. The Oracle documentation has some preinstallation request to be carried before installing the Oracle software. It asks to modify some SEMAPHORE & SHARED MEMORY values in to a specified file. And finally after updating this values it... (2 Replies)
Discussion started by: S.Vishwanath
2 Replies
Login or Register to Ask a Question
MLY(4)							   BSD Kernel Interfaces Manual 						    MLY(4)

NAME
mly -- Mylex AcceleRAID/eXtremeRAID family driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device da device mly Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): mly_load="YES" DESCRIPTION
The mly driver provides support for Mylex AcceleRAID and eXtremeRAID-family PCI to SCSI RAID controllers with version 6.00 and later firmware. Logical devices (array drives) attached to the controller are presented to the SCSI subsystem as though they were direct-access devices on a virtual SCSI bus. Physical devices which are not claimed by a logical device are presented on SCSI channels which match the physical chan- nels on the controller. HARDWARE
Controllers supported by the mly driver include: o Mylex AcceleRAID 160 o Mylex AcceleRAID 170 o Mylex AcceleRAID 352 o Mylex eXtremeRAID 2000 o Mylex eXtremeRAID 3000 Compatible Mylex controllers not listed should work, but have not been verified. DIAGNOSTICS
Controller initialisation phase mly%d: controller initialisation started mly%d: initialisation complete The controller firmware has started initialisation. Normally this process is performed by the controller BIOS, but the driver may need to do this in cases where the BIOS has failed, or is not compatible (e.g. on non-x86 systems). mly%d: drive spinup in progress Drive startup is in progress; this may take several minutes. mly%d: mirror race recovery failed, one or more drives offline mly%d: mirror race recovery in progress mly%d: mirror race recovery on a critical drive These error codes are undocumented. mly%d: FATAL MEMORY PARITY ERROR Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. mly%d: unknown initialisation code %x An unknown error occurred during initialisation; it will be ignored. Driver initialisation/shutdown phase mly%d: can't enable busmaster feature mly%d: memory window not available mly%d: can't allocate register window mly%d: can't allocate interrupt mly%d: can't set up interrupt The system's PCI BIOS has not correctly configured the controller's PCI interface; initialisation has failed and the driver will not attach to this controller. mly%d: can't allocate parent DMA tag mly%d: can't allocate buffer DMA tag mly%d: can't allocate command packet DMA tag mly%d: can't allocate scatter/gather DMA tag mly%d: can't allocate s/g table mly%d: can't allocate memory mailbox DMA tag mly%d: can't allocate memory mailbox A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. mly%d: BTL rescan result corrupted The results of a scan for an attached device were corrupted. One or more devices may not be correctly reported. mly%d: flushing cache... The controller cache is being flushed prior to detach or shutdown. Operational diagnostics mly%d: physical device %d:%d online mly%d: physical device %d:%d standby mly%d: physical device %d:%d automatic rebuild started mly%d: physical device %d:%d manual rebuild started mly%d: physical device %d:%d rebuild completed mly%d: physical device %d:%d rebuild cancelled mly%d: physical device %d:%d rebuild failed for unknown reasons mly%d: physical device %d:%d rebuild failed due to new physical device mly%d: physical device %d:%d rebuild failed due to logical drive failure mly%d: physical device %d:%d found mly%d: physical device %d:%d gone mly%d: physical device %d:%d unconfigured mly%d: physical device %d:%d expand capacity started mly%d: physical device %d:%d expand capacity completed mly%d: physical device %d:%d expand capacity failed mly%d: physical device %d:%d parity error mly%d: physical device %d:%d soft error mly%d: physical device %d:%d miscellaneous error mly%d: physical device %d:%d reset mly%d: physical device %d:%d active spare found mly%d: physical device %d:%d warm spare found mly%d: physical device %d:%d initialization started mly%d: physical device %d:%d initialization completed mly%d: physical device %d:%d initialization failed mly%d: physical device %d:%d initialization cancelled mly%d: physical device %d:%d write recovery failed mly%d: physical device %d:%d scsi bus reset failed mly%d: physical device %d:%d double check condition mly%d: physical device %d:%d device cannot be accessed mly%d: physical device %d:%d gross error on scsi processor mly%d: physical device %d:%d bad tag from device mly%d: physical device %d:%d command timeout mly%d: physical device %d:%d system reset mly%d: physical device %d:%d busy status or parity error mly%d: physical device %d:%d host set device to failed state mly%d: physical device %d:%d selection timeout mly%d: physical device %d:%d scsi bus phase error mly%d: physical device %d:%d device returned unknown status mly%d: physical device %d:%d device not ready mly%d: physical device %d:%d device not found at startup mly%d: physical device %d:%d COD write operation failed mly%d: physical device %d:%d BDT write operation failed mly%d: physical device %d:%d missing at startup mly%d: physical device %d:%d start rebuild failed due to physical drive too small mly%d: physical device %d:%d sense data received mly%d: sense key %d asc %02x ascq %02x mly%d: info %4D csi %4D mly%d: physical device %d:%d offline mly%d: sense key %d asc %02x ascq %02x mly%d: info %4D csi %4D The reported event refers to the physical device at the given channel:target address. mly%d: logical device %d (%s) consistency check started mly%d: logical device %d (%s) consistency check completed mly%d: logical device %d (%s) consistency check cancelled mly%d: logical device %d (%s) consistency check completed with errors mly%d: logical device %d (%s) consistency check failed due to logical drive failure mly%d: logical device %d (%s) consistency check failed due to physical device failure mly%d: logical device %d (%s) automatic rebuild started mly%d: logical device %d (%s) manual rebuild started mly%d: logical device %d (%s) rebuild completed mly%d: logical device %d (%s) rebuild cancelled mly%d: logical device %d (%s) rebuild failed for unknown reasons mly%d: logical device %d (%s) rebuild failed due to new physical device mly%d: logical device %d (%s) rebuild failed due to logical drive failure mly%d: logical device %d (%s) offline mly%d: logical device %d (%s) critical mly%d: logical device %d (%s) online mly%d: logical device %d (%s) initialization started mly%d: logical device %d (%s) initialization completed mly%d: logical device %d (%s) initialization cancelled mly%d: logical device %d (%s) initialization failed mly%d: logical device %d (%s) found mly%d: logical device %d (%s) gone mly%d: logical device %d (%s) expand capacity started mly%d: logical device %d (%s) expand capacity completed mly%d: logical device %d (%s) expand capacity failed mly%d: logical device %d (%s) bad block found mly%d: logical device %d (%s) size changed mly%d: logical device %d (%s) type changed mly%d: logical device %d (%s) bad data block found mly%d: logical device %d (%s) read of data block in bdt mly%d: logical device %d (%s) write back data for disk block lost The event report will include the name of the SCSI device which has attached to the device if possible. mly%d: enclosure %d fan %d failed mly%d: enclosure %d fan %d ok mly%d: enclosure %d fan %d not present mly%d: enclosure %d power supply %d failed mly%d: enclosure %d power supply %d ok mly%d: enclosure %d power supply %d not present mly%d: enclosure %d temperature sensor %d failed mly%d: enclosure %d temperature sensor %d critical mly%d: enclosure %d temperature sensor %d ok mly%d: enclosure %d temperature sensor %d not present mly%d: enclosure %d unit %d access critical mly%d: enclosure %d unit %d access ok mly%d: enclosure %d unit %d access offline These events refer to external enclosures by number. The driver does not attempt to name the enclosures. mly%d: controller cache write back error mly%d: controller battery backup unit found mly%d: controller battery backup unit charge level low mly%d: controller battery backup unit charge level ok mly%d: controller installation aborted mly%d: controller mirror race recovery in progress mly%d: controller mirror race on critical drive mly%d: controller memory soft ecc error mly%d: controller memory hard ecc error mly%d: controller battery backup unit failed These events report controller status changes. AUTHORS
The mly driver was written by Michael Smith <msmith@FreeBSD.org>. This manual page was written by Michael Smith <msmith@FreeBSD.org>. BUGS
The driver does not yet provide an external management interface. Enclosures are not named or otherwise identified in event messages. BSD
August 10, 2004 BSD