People i have solaris 9 in a sparc platform i`m tryng to conect a stora edge a5100.When i do a format i don't see the disk, later i do a touch /reconfigure reboot and nothing cant anybody help me?
Determine if the StorEdge A5x00 array packages need to be installed on the nodes to which you are connecting the StorEdge A5x00 array. This product requires the following packages.
# pkginfo | egrep Wlux
system SUNWluxd Sun Enterprise Network Array sf Device Driver
system SUNWluxdx Sun Enterprise Network Array sf Device Driver (64-bit)
system SUNWluxl Sun Enterprise Network Array socal Device Driver
system SUNWluxlx Sun Enterprise Network Array socal Device Driver (64-bit)
system SUNWluxop Sun Enterprise Network Array firmware and utilities
u2:/ # pkginfo | grep Wlux
system SUNWluxd Sun Enterprise Network Array sf Device Driver
system SUNWluxdx Sun Enterprise Network Array sf Device Driver (64-bit)
system SUNWluxl Sun Enterprise Network Array socal Device Driver
system SUNWluxlx Sun Enterprise Network Array socal Device Driver (64-bit)
system SUNWluxop Sun Enterprise Network Array firmware and utilities
system SUNWluxox Sun Enterprise Network Array libraries (64-bit)
You could try running luxadm commands to see if those show you anything...
luxadm insert_device (sorry, didn't have an example in my old notes)
luxadm probe command should show any connected arrays/disks on the fiber connection
Code:
# luxadm probe
Found Enclosure(s):
SENA Name:oltp-a Node WWN:5080020000021a20
Logical Path:/dev/es/ses0
Logical Path:/dev/es/ses1
SENA Name:oltp-b Node WWN:5080020000021f48
Logical Path:/dev/es/ses2
Logical Path:/dev/es/ses3
SENA Name:oltp-d Node WWN:5080020000026c28
Logical Path:/dev/es/ses4
Logical Path:/dev/es/ses5
SENA Name:oltp-c Node WWN:5080020000026dc8
Logical Path:/dev/es/ses6
Logical Path:/dev/es/ses7
If there is something there, you can look at the one specific array...
Code:
# luxadm display oltp-b
(luxadm version: 1.45 SunOS 5.6)
SENA
DISK STATUS
SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)
0 On (O.K.) 20000020370e855c On (O.K.) 20000020370e1fb1
1 On (O.K.) 20000020370e801e On (O.K.) 20000020372d1678
2 On (O.K.) 20000020370e72cf On (O.K.) 20000020370e6cfc
3 On (O.K.) 20000020370e8266 On (O.K.) 20000020370e6db1
4 On (O.K.) 20000020370e840c On (O.K.) 20000020370973b5
5 On(No UNIX Label) 20000020370e7dd8 On (O.K.) 20000020370e6ddc
6 On (O.K.) 20000020370e8602 On (O.K.) 20000020370e6908
SUBSYSTEM STATUS
FW Revision:1.08 Box ID:1 Node WWN:5080020000021f48 Enclosure Name:oltp-b
Power Supplies (0,2 in front, 1 in rear)
0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
0 O.K.(rev.-05) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
A: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
B: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
Disk backplane (0 in front, 1 in rear)
Front Backplane: O.K.(rev.-04)
Temperature sensors (on front backplane)
0:37ºC 1:39ºC 2:37ºC 3:37ºC 4:36ºC 5:37ºC
6:37ºC (All temperatures are NORMAL.)
Rear Backplane: O.K.(rev.-04)
Temperature sensors (on rear backplane)
0:36ºC 1:37ºC 2:39ºC 3:37ºC 4:37ºC 5:37ºC
6:39ºC (All temperatures are NORMAL.)
Interconnect assembly
O.K.(rev.-02)
Loop configuration
Loop A is configured as a single loop.
Loop B is configured as a single loop.
Language USA English
No i do it and i see
u2:/ # luxadm probe
No Network Array enclosures found in /dev/es
i change de fc cable everthing i believe that is a storage problem.
---------- Post updated at 01:13 PM ---------- Previous update was at 01:11 PM ----------
sorry i connect the storage do a touch /reconfigure and init 6. All this i do it, but i cannot see the storage.
i hava a storage more old than the a5100 and works perfects.
I have vmware on my windows PC ( hostname : acer ).
vmware has RHEL 7 ( hostname : rhel7 ) installed recently.
RHEL IP configuration
IP : 192.168.5.128
Netmask : 255.255.255.0
ssh to rhel7 works from acer using putty
resolve.conf
cat /etc/resolv.conf
nameserver 192.168.5.1
host... (12 Replies)
Hi,
I would like to ask if someone experince this problem on a Hard disc. I had a 320 GB WD Blue 3.5 Hard disc. When i plug on my PC BIOS detect it for a while and dis-appear. Luckily sometimes i can check it on a bootable CD or attach on other LINUX PC but for a while it will dis-appear. As if... (3 Replies)
Hi,
When I try to create a virtual disk in IVM ( integrated Virtual Machine VIO ) I get this message
Problems occurred while processing the data. A summary of all problems for this page are listed below. Additional details for each problem may be located next to the field causing the... (0 Replies)
Hi gurus
I don't understand the below messages as what is going on with my storage
Plz kindly suggest what could be the problem
Script started on Tue 12 May 2009 09:22:13 AM GMT
OMP-root-/salil> uptime
9:22am up 19:44, 2 users, load average: 0.10, 0.08, 0.08
OMP-root-/salil> uname -a... (4 Replies)
Dear Expert ,
We have L7 , when we power on we see on lcd messages "drive Post E" , According sun Doc SunSolve , there problem picker or Driver , I try move slot to slot successfully, On Lcd panel i can not see load drive (look like any inside tape in drive , but when i am select eject menu,... (0 Replies)
I have the following problem to be solved:
I read a .csv file (tempfile), fetch the values into variables F1 to F5.
Variables F1, F2, F3 are parameters used for running a program (blablaprogram).
Variable F4 I want to use to store the PID-value in and variable F5 is used for storing the return... (3 Replies)
Dear linuxers,
I have a usb mess storage device.
My OS is rh as3 update2.
Each time I use the command
mount -t vfat /dev/sda1 /mnt/usb
I got the error "the device is not a valid block device".
I found from google that I should install the module sd_mod
I use the command
insmod sd_mod... (2 Replies)