10 More Discussions You Might Find Interesting
1. Solaris
Hello All,
I am having an issue with ellipse environment,
Subscribing ellipse version /opt/mincom/ellipse/bs037__ora_cics_svr
.profile: ulimit: exceeds allowable limit ,
prj -l ellsupp
#ulimit -a
time(seconds) unlimited
file(blocks) unlimited
data(kbytes) unlimited
stack(kbytes) 8192... (22 Replies)
Discussion started by: Revathi2089
22 Replies
2. UNIX and Linux Applications
Just had a migration from Autosys 4.5 to R11.3.
After the migration to R11.3, Autosys jobs have been failing when the log file reaches a size of 800 MB.
This did not happen before the migration, when Autosys 4.5 was used.
Is there a way to configure the file size limit/cap in Autosys... (1 Reply)
Discussion started by: kimo222
1 Replies
3. Solaris
I have BIND 9.8.1-P1 cache only DNS server running in Solaris 10. I have upgraded the same from 9.6.1 to 9.8.1-P1. Now i am facing "file descriptor exceeds limit (4096/4096)" error frequently on the server.
Please help me on this issue! (1 Reply)
Discussion started by: sandeep.tk
1 Replies
4. Shell Programming and Scripting
How can i remove a file using shell script when its size exceeds 10MB. Given that file is located in different location to the shell script where it is running? (4 Replies)
Discussion started by: vel4ever
4 Replies
5. UNIX for Dummies Questions & Answers
Hi all.
I am trying to write a script that renames a logfile if it exceeds roughly 1 MB.
My find command is:
find some_logfile -type f -size +20000
Now I want to do my processing if it finds a file or not...
How can I go about this? The $? is 0 if it finds a file or not.
All... (4 Replies)
Discussion started by: jamie_collins
4 Replies
6. Shell Programming and Scripting
Everytime I try to start Discreet Flame on my Octane2 machine it keeps giving me an error message "initial log size exceeds limit--aborting"
Can anyone please help me how to fix this problem. Thanks.
Octane2
IRIX64 Release 6.5
Flame 2007 (6 Replies)
Discussion started by: dewaraja
6 Replies
7. UNIX for Advanced & Expert Users
Everytime I try to start Discreet Flame on my Octane2 machine it keeps giving me an error message "initial log size exceeds limit--aborting"
Can anyone please help me how to fix this problem. Thanks.
Octane2
IRIX64 Release 6.5
Flame 2007 (0 Replies)
Discussion started by: dewaraja
0 Replies
8. Linux
Hi,
I'm using Linux 2.6 cross compiled for a embedded powerpc.
Earlier we were using busybox syslogd for logging the messages, but as the flexibilty is less, we decided to move to standard syslog.
Now I want to limit the size of the log file (/var/log/messages) to 128K.
I couldn't find... (4 Replies)
Discussion started by: jockey007
4 Replies
9. Shell Programming and Scripting
Hi EveryOne
We run CICS Sofware on our AIX Machine...
When ever some Process or Transaction loops it Takes heavy process Usage..
Is there a way that i can Get a alert message or a Message Thrown on to screen when ever a process named "cicsas" uses more that 20%... fo CPU..
I was... (4 Replies)
Discussion started by: pbsrinivas
4 Replies
10. UNIX for Dummies Questions & Answers
Hi,
I am trying to write a script to Count Files in a directory located on a remote server and send an email Notification if it exceeds a limit. The code given below doesnot check the condition and sends the mail everytime irrespective of the condition. I have put this script in the cron. Can... (10 Replies)
Discussion started by: amitsayshii
10 Replies
LOGGER(1) BSD General Commands Manual LOGGER(1)
NAME
logger -- make entries in the system log
SYNOPSIS
logger [-is] [-d SD] [-f file] [-m msgid] [-p pri] [-t tag] [message ...]
DESCRIPTION
logger provides a shell command interface to the syslog(3) system log module.
Options:
-d sd Log this in the structured data (SD) field. (sd has to be passed as one argument and will require careful quoting when used from
the shell.)
-f file Log the specified file.
-i Log the process id of the logger process with each line.
-m msgid The MSGID used for the message.
-p pri Enter the message with the specified priority. The priority may be specified numerically or as a ``facility.level'' pair. For
example, ``-p local3.info'' logs the message(s) as informational level in the local3 facility. The default is ``user.notice''.
-s Log the message to standard error, as well as the system log.
-t tag Mark every line in the log with the specified tag.
message Write the message to log; if not specified, and the -f flag is not provided, standard input is logged.
EXIT STATUS
The logger utility exits 0 on success, and >0 if an error occurs.
EXAMPLES
logger System rebooted
logger -p local0.notice -t HOSTIDM -f /dev/idmc
SEE ALSO
syslog(3), syslogd(8)
STANDARDS
The logger utility conforms to IEEE Std 1003.2-1992 (``POSIX.2'').
BSD
May 14, 2010 BSD