Hi guys,
i must install an old old old ml370 server...
I must create a RAID 5 with my 4 SCSI disk.
I need a SmartStart disk for create it or a Floppy Disk called "Array configuration Tool". I don't find it on the hp website...
Anyone have it??
Hello community, after hours (days) spent to understand what's the problem reported also in the following thread: https://www.unix.com/red-hat/278892-cant-boot-rhel7-2-due-start-job-running.html
I realize that the problem is the server itself. I opened a new thread since the issue in not related... (2 Replies)
Dear all ,
i ve configured raid 0 in redhat machine(VM ware), by following steps:
#mdadm -C /dev/md0 -l 0 -n 2 /dev/sdb1 /dev/sdc1
#mkfs.ext3 /dev/md0
#mdadm --detail --scan --config=mdadm.conf >/etc/mdadm.conf
then
mounted the/dev/md0 device and also added a entry in fstab.
how... (2 Replies)
One of my very old drive farm servers had an OS fault and can't boot now but I'd like to restore some files from it. I tried booting Ubuntu from a CD, but it couldn't see the drives -- possibly because they're RAIDed together. Is there a good way to get at my files?
The data in question is a... (2 Replies)
Hi,
I wish to store $string1 in $string1array a character in each array element.
Then i wish to echo the entire array to the screen so that it reads as the normal string again.
I have been trying with the code below but does not work. Please help...
To put string into array:
... (5 Replies)
Hi, there are tons of RAID1 tutorials, but none of them deal with lvm. The problem is that I want to expand my current lvm partition over RAID1 rather than creating a new lvm partition after RAID1 is created.
My master harddrive has lvm partition. I'm wondering how to create a RAID1 image of... (1 Reply)
I created a RAID 5 array and when I list out the attributes of the "hdisk" it reports back raid_level = 5 but the RAID level of the array = false. What does this actually indicate about my array? I've never paid much attention to this until now since I have a disk reporting failure I want to make... (0 Replies)
I have a new Rp4440 that has hp-ux 11.11 on it with a smart array 30 attached to it, HP says they are compatiable and i should be able to use it. I am looking for any help in setting up the array i have it all connected but dont know how to setup the array so the OS see's hard drives. I got no... (1 Reply)
Trying to install Sco openserver on HP Proliant with this scsi controller but no scsi devices detected.
Boot controller is set as the smart array 532 but SCSI diags do not detect any SCSI boot devices during boot sequence
Any help appreciated (2 Replies)
HPSA(4) Linux Programmer's Manual HPSA(4)NAME
hpsa - HP Smart Array SCSI driver
SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ]
DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers.
Options
hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not
explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of
operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that
would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4)
should still be used for these.
Supported hardware
The hpsa driver supports the following Smart Array boards:
Smart Array P700M
Smart Array P212
Smart Array P410
Smart Array P410i
Smart Array P411
Smart Array P812
Smart Array P712m
Smart Array P711m
StorageWorks P1210m
Since Linux 4.14, the following Smart Array boards are also supported:
Smart Array 5300
Smart Array 5312
Smart Array 532
Smart Array 5i
Smart Array 6400
Smart Array 6400 EM
Smart Array 641
Smart Array 642
Smart Array 6i
Smart Array E200
Smart Array E200i
Smart Array E200i
Smart Array E200i
Smart Array E200i
Smart Array E500
Smart Array P400
Smart Array P400i
Smart Array P600
Smart Array P700m
Smart Array P800
Configuration details
To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based
Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time.
FILES
Device nodes
Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the
SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively.
HPSA-specific host attribute files in /sys
/sys/class/scsi_host/host*/rescan
This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g.,
hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected.
Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus,
for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging
devices like tape drives, or entire storage boxes containing preconfigured logical drives.
/sys/class/scsi_host/host*/firmware_revision
This attribute contains the firmware version of the Smart Array.
For example:
# cd /sys/class/scsi_host/host4
# cat firmware_revision
7.14
HPSA-specific disk attribute files in /sys
/sys/class/scsi_disk/c:b:t:l/device/unique_id
This attribute contains a 32 hex-digit unique ID for each logical drive.
For example:
# cd /sys/class/scsi_disk/4:0:0:0/device
# cat unique_id
600508B1001044395355323037570F77
/sys/class/scsi_disk/c:b:t:l/device/raid_level
This attribute contains the RAID level of each logical drive.
For example:
# cd /sys/class/scsi_disk/4:0:0:0/device
# cat raid_level
RAID 0
/sys/class/scsi_disk/c:b:t:l/device/lunid
This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are
the controller, bus, target, and lun of the device.
For example:
# cd /sys/class/scsi_disk/4:0:0:0/device
# cat lunid
0x0000004000000000
Supported ioctl() operations
For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are
also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file
include/linux/cciss_ioctl.h.
CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD
These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the
same thing as writing to the hpsa-specific host "rescan" attribute.
CCISS_GETPCIINFO
Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID).
CCISS_GETDRIVVER
Returns driver version in three bytes encoded as:
(major_version << 16) | (minor_version << 8) |
(subminor_version)
CCISS_PASSTHRU, CCISS_BIG_PASSTHRU
Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration
Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples.
SEE ALSO cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8),
<http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source
tree
COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the
latest version of this page, can be found at https://www.kernel.org/doc/man-pages/.
Linux 2017-09-15 HPSA(4)