9 More Discussions You Might Find Interesting
1. Solaris
I am trying to connect D1000 storedge with my sun blade 1500 and i am getting the following error when booting the system.
Oct 13 22:21:56 brampton rpcbind: rpcbind terminating on signal.
Oct 13 22:22:02 brampton syseventd: SIGHUP caught - reloading modules
Oct 13 22:22:02 brampton... (9 Replies)
Discussion started by: mnathan
9 Replies
2. Filesystems, Disks and Memory
Alguien me puede ayudar, necesito saber cuantos slot de memoria disponibles tiene un RS/6000 AIX (1 Reply)
Discussion started by: ivan.estay
1 Replies
3. Solaris
Hi,
Recently i was trying to connect Sun Storedge D1000 Array to E420 R (Practice servers). I connected the SCSI cable between array and server. I tried the following :
#devfsadm (nothing showed up)
#format (no new disk is shown here)
i tried this process again after putting ON the... (2 Replies)
Discussion started by: bluegold86
2 Replies
4. Solaris
hi all,
i have a sunfire v440 server , someone can tell me if this server contains a AGP slots ? thanx (4 Replies)
Discussion started by: lid-j-one
4 Replies
5. Solaris
Hello,
I have a d1000, it's connected to two servers, I want both servers to see all disks in the array. i.e. i have 6 disks, 3 in each side, I want both servers to see all 6 disks.
It appears to be setup in a split bus mode now, ive looked thru the manuals and have become confused!
So,... (2 Replies)
Discussion started by: BG_JrAdmin
2 Replies
6. Solaris
Hi everyone,
I have a problem which looks like very simple. My SunFire X4100 have 2 disk slots: HDD0, HDD1 and 1 hard disk. I installed OS on the hard disk at HDD0 and now i want to boot it at HDD1.
When i change BIOS and begin boot at HDD1 it reset after i chose Solaris 10 at OS selecting... (3 Replies)
Discussion started by: tien86
3 Replies
7. Solaris
Hi folks,
I´m having a problem with a Ultra60 box with diff scsi pci card
conected to one D1000. The conection are correct because a checked the
D1000 guide. When a do probe-scsi-all in the OBP, the D1000 blink all
disks one time then the led of one of the disks powers off and then
nothing... (2 Replies)
Discussion started by: spacewalker
2 Replies
8. UNIX for Dummies Questions & Answers
Hi,
im having a problem installing my pci wireless card. Im using knoppix, but my problem is with the mobo i think. im using an older laptop, toshiba satellite 2540 and when i plug in the card i get lights on sometimes. this means its getting power right. so then to install the card into the... (0 Replies)
Discussion started by: jestra
0 Replies
9. UNIX for Advanced & Expert Users
Hi all..
I have a Sun Ultra 450 with a lot of drives and scsi controllers installed and i have one bad internal disk.. How can "map" ex /dev/dsk/c3t2d0s0 to a slot in the internal cabinet? Any good ideas?
I dont want to remove the wrong disk :)
thanks in advance.. (3 Replies)
Discussion started by: s93366
3 Replies
vximportdg(1M) vximportdg(1M)
NAME
vximportdg - import a disk group into the Veritas Volume Manager configuration
SYNOPSIS
vximportdg daname new_dgname
DESCRIPTION
The vximportdg utility performs a temporary import of the disk group contained on the disk device specified by daname to the disk group
specified by new_dgname. As the persistent disk group information is not changed within the private partition of the affected disk, the
import is only valid for the duration of the bootload or until a vxdg deport is performed.
ARGUMENTS
daname Specifies the device name (disk access name) of one of the member disks of the disk group to be imported. The other members are
imported automatically.
new_dgname
Specifies the disk group to be imported.
USAGE
One reason to use the vximportdg utility is to import a second generation of the rootdg disk group so that its objects are available for
use while a system is running on a different rootdg. To prevent volumes on the second generation rootdg from having the same device minor
numbers as volumes (such as rootvol) on the active rootdg, the importation assigns temporary non-conflicting device minor numbers. If this
occurs, vximportdg outputs warning messages detailing the mapping of the minor numbers.
SEE ALSO
vxdg(1M)