Quote:
Originally Posted by mgonzal
Hi... I have a IBM pseries with AIX 4.3... and the root user receive the next error (via e-mail) diagela
A PROBLEM WAS DETECTED ON Thu Aug 18 04:01:05 AST 2005 801014
The Service Request Number(s)/Probable Cause(s) (causes are listed in descending order of probability):
651-880: The CEC or SPCN reported an error. Report the SRN and the
following reference and physical location codes to your service
provider.
Error log information:
Sequence number: 244337
Ref. Code: 10111920 FRU: 09P6693 U1.1-V2
Can anybody guide me how to manage this problem??? I seach at ibm site and put the 6 digits but i couldn't find the solution.
WHY THIS ERROR OCCURS?
Thanks anticipated for any help.
Hi,
have you found out a solution for your problem? After change of the power supply unit, I get the same error message.
For the code 651-88x I get the following information:
"The CEC or SPCN reported an error.
Action: Refer to theentry MAP in this system unitsīs system service guide, with the 8 digit error and location codes, for the necessary repair action. If the 8 digit error and location codes were NOT reported, then run Advanced Diagnostics in Prolbem Dermination mode an record and report the 8 digit error and location codes for this SRN."
After the change of the power supply unit which has an error I only have to reset the diagela with:
1. Save the errpt log:
errpt -a > /tmp/errpt.log
2. Reset the diagela log:
errclear 0
The parameter 0 means that all days were deleted, if you set 1 instead you get the waring from the last warning.