9 More Discussions You Might Find Interesting
1. Solaris
All,
One-way mirror. Elements of the concat in Last-errd state. What would be the best way to correct it?
metastat -s db2test -pc
db2test/d220 p 5.0GB db2test/d200
db2test/d219 p 5.0GB db2test/d200
db2test/d218 p 5.0GB db2test/d200
db2test/d217 p 30GB db2test/d200... (0 Replies)
Discussion started by: ossupport55
0 Replies
2. Solaris
Hi Guys,
I need a help with attaching the sub mirrors as it keep throwing errors.
I have done solaris live upgrade and it was succesful but it keeps throwing error only for root (s0) and swap (s1)when i try to attach them.
For rest of the partitions for slices 3,4,5 on target 1 are able to... (4 Replies)
Discussion started by: phanidhar6039
4 Replies
3. Solaris
Hi,
Ii am facing the belwo problem:
d50: Mirror
Submirror 0: d30
State: Needs maintenance
Submirror 1: d40
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 212176648 blocks (101 GB)
d30:... (3 Replies)
Discussion started by: sag71155
3 Replies
4. Shell Programming and Scripting
Hello...
I am trying to convert my script from one to another unix flavor...
from reliant to solaris...I did all but can not convert this awk/nawk:
First code if code that works what I want under reliant and the second should do same under solaris but it does not
I did so far from this :... (2 Replies)
Discussion started by: abdulaziz
2 Replies
5. Shell Programming and Scripting
Hello...
I have script that works perfect on solaris but on Reliant UNIX sometimes it does not work ...I send files to my Xp(from Reliant UNIX) but if I try to send it to my solaris machine file can not be send...
script is:
#!/bin/ksh
localFile=$1
remoteFile=$2
... (0 Replies)
Discussion started by: amon
0 Replies
6. Solaris
Ok, so I have a remote system (7 states away) that's using SDS to manage the two 18 gig disks. /, swap, /var, /home, and /opt.
The mirroring procedure I created uses installboot to ensure there's a bootblk on both disks of an SDS mirror.
The system has a problem booting (can't write to... (21 Replies)
Discussion started by: BOFH
21 Replies
7. Filesystems, Disks and Memory
Hi Folks,
This one has me a bit confused.
I have a large system running Reliant 5.45 with an EMC 3930 disk array fibre attached. As part of our requirement I implemented host level mirroring in addition to the BCV functionality provided by the 3930.
When the mirrors are split and the... (0 Replies)
Discussion started by: gull04
0 Replies
8. Solaris
:confused: Hello folks, my company had decided to migrate from Reliant Unix to Solaris. We have an amount of sources
that have to be changed a little, because these UNIX'es are slightly different. Is there a tool (hopefully free), which can do this job? Does anyone know the exactly differences, I... (2 Replies)
Discussion started by: MS-No
2 Replies
9. UNIX for Dummies Questions & Answers
Hi,
I've got a problem with the copy - command (reliant unix 5.43). It appears to me rather difficult to copy large amount of data. A command like "cp *.jpg" is simply refused. Does anybody know something about such a kind of restriction? Something like ... only 256 files could be copied at... (2 Replies)
Discussion started by: sysadv
2 Replies
BI2CF(6) BI2CF(6)
NAME
bi2cf - a map conversion tool for Crimson Fields
SYNOPSIS
bi2cf mapname [-p 1|2] [-f b|1|2|h] [-l] [-t mapname] [-i mapinfo] [-o outfile] [-d mapdir] [-O destdir] [-q]
bi2cf {-h | -v}
DESCRIPTION
bi2cf is a map conversion tool for Crimson Fields. It takes the data files of maps from Battle Isle, Battle Isle Data Disk 1 or 2, or
History Line 1914-1918 and converts them into map sources usable with the cfed(6) map compiler for Crimson Fields. bi2cf can handle both
uncompressed maps and levels crunched with TPWM.
For some units and tiles there are no corresponding counterparts in Crimson Fields. These cases are mapped to similar ones if available. As
a result some maps will not be as balanced as the originals, others may be unwinnable, and still others may even fail to compile. If this
happens the map in question needs to be adjusted manually.
OPTIONS
-d mapdir
Set the location of the Battle Isle map files.
-f b|1|2|h
Force map type to Battle Isle / BI Data Disk 1 / BI Data Disk 2 / History Line, respectively. Use this option when map format
autodetection does not work correctly. Maps from BI Data Disk 1 will always be detected as standard Battle Isle maps, so you have to use
-f 1 in that case.
-h
Print a usage message on standard output and exit.
-i mapinfo
Set map info message.
-l
Skip last row and column of the map. This is necessary for maps from the PC version of Battle Isle.
-o outfile
Write map to file outfile. Default file name is mapname.src.
-O destdir
Set target directory for the converted map. This setting is ignored if a map name was given using the -t option.
-p 1|2
Set default number of players for this map.
-q
Run quietly. Don't print processing information on standard output.
-t mapname
Set title and file name for the converted map. Default is maptype-mapname.
-v
Print version information on standard output and exit.
SEE ALSO
cfed(6), crimson(6)
COPYRIGHT
Copyright (C) 2002 Florian Dietrich
This software is distributed under the terms of the [1]GNU General Public License (GPL).
AUTHOR
Florian Dietrich <n8flo@yahoo.de>
Author.
REFERENCES
1. GNU General Public License
http://www.gnu.org/copyleft/gpl.html
Jan 30 2003 BI2CF(6)