Bank-Verlag: Linux Migration and SAP System Operation by Pironet NDH - PresseBox (Pre
Bank-Verlag: Linux Migration and SAP System Operation by Pironet NDH PresseBox (Pressemitteilung)(abonnement), Germany - 25 minutes ago Whereas the server that was hitherto in use employed the Unix operating system, the new hardware runs under the Linux Distribution from Red Hat. ...
We would be migrating UNIX file system to Linux file system.
We do have many directory and sub directories with files.
after migrating unix to linux file system , i want to make sure all the files has been copied ? What would be the best approach to validate directory ,sub-directory and file... (1 Reply)
Am actually am new to the linux operating system and knda wana knw more about it.Please could u help me with some commands so i can start with that first.Really need your help (5 Replies)
Does anyone can write a thread to teach me how to install Windows 2000, RH Linux, and FreeBSD unix in one machine step by step? Or someone's already done with this topic? (1 Reply)
sfe(7D) Devices sfe(7D)NAME
sfe - SiS900 series Fast Ethernet device driver
SYNOPSIS
/dev/sfe
DESCRIPTION
The sfe driver is a loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface dlpi(7P) on Silicon Inte-
grated Systems 900 series Fast Ethernet controllers.
APPLICATION PROGRAMMING INTERFACE
The relevant fields returned as part of a DL_INFO_ACK response are:
o Maximum SDU is 1500.
o Minimum SDU is 0.
o The dlsap address length is 8.
o MAC type is DL_ETHER.
o SAP length is -2. The 6-byte physical address is followed immediately by a 2-byte SAP.
o Service mode is DL_CLDLS.
o Broadcast address is the 6-byte Ethernet broadcast address (ff:ff:ff:ff:ff:ff).
If the SAP provided is zero, then IEEE 802.3 mode is assumed and outbound frames will have the frame payload length written into the type
field. Likewise, inbound frames with a SAP between zero and 1500 are interpreted as IEEE 802.3 frames and delivered to any streams that are
bound to SAP zero (the 802.3 SAP).
PROPERTIES
The following properties may be configured using either ndd(1M) or the sfe.conf configuration file as described by driver.conf(4):
adv_100fdx_cap
Enables the 100 Base TX full-duplex link option. (This is generally the fastest mode if both link partners support it. Most modern
equipment supports this mode.)
adv_100hdx_cap
Enables the 100 Base TX half-duplex link option. (Typically used when the link partner is a 100 Mbps hub.)
adv_10fdx_cap
Enables the 10 Base-T full-duplex link option. (This less-frequently used mode is typically used when the link partner is a 10 Mbps
switch.)
adv_10hdx_cap
Enables the 10 Base-T half-duplex link option. (This is the fall-back when no other option is available. It is typically used when
the link partner is a 10 Mbps hub or is an older network card.)
ATTRIBUTES
See attributes(5) for a description of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SPARC, x86 |
+-----------------------------+-----------------------------+
|Interface Stability |Committed |
+-----------------------------+-----------------------------+
FILES
/dev/sfe
Special character device.
/kernel/drv/sfe
32-bit driver binary (x86).
/kernel/drv/amd64/sfe
64-bit driver binary (x86).
/kernel/drv/sparcv9/sfe
64-bit driver binary (SPARC).
/kernel/drv/sfe.conf
Configuration file.
SEE ALSO ndd(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P)
IEEE 802.3 -- Institute of Electrical and Electronics Engineers, 2002
SunOS 5.11 12 Dec 2007 sfe(7D)