Veritas Storage Question (Data Migration)


 
Thread Tools Search this Thread
Operating Systems Solaris Veritas Storage Question (Data Migration)
# 1  
Old 02-03-2009
Veritas Storage Question (Data Migration)

Using Solaris 10 with Veritas Storage Foundation running. I want to copy all contents from DISKA LUN1 to DISKB LUN2. What would be the command syntax to do this?
Login or Register to Ask a Question

Previous Thread | Next Thread

8 More Discussions You Might Find Interesting

1. AIX

AIX - FC Switch migration, SAN Migration question!

I'm New to AIX / VIOS We're doing a FC switch cutover on an ibm device, connected via SAN. How do I tell if one path to my remote disk is lost? (aix lvm) How do I tell when my link is down on my HBA port? Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies

2. Hardware

Storage migration from VMAX to VNXHe

Hello, We are considering storage migration for RAC database servers(using ASM) from VMAX to VNX? Any good/bad pointers in this regards please. Best regards, Vishal (1 Reply)
Discussion started by: admin_db
1 Replies

3. Solaris

Storage migration: zones and metasets

Hi all, I'm in a situation which i need to understand the best way of doing a migration of storage involved in a zone.Elements involved are solaris 10 (Generic_144488-08), metasets. I need to provision more storage to the said non-global zone and not aware of the "best practices" from the ... (2 Replies)
Discussion started by: ossupport55
2 Replies

4. Filesystems, Disks and Memory

VERITAS Storage Foundation

Hi I have some practical experience with VERITAS Volume Manager and File System. Now I want to appear for VERITAS Storage Foundation 5.0 certification. From my previous experience with Solaris certification I can say that some kind of preparation with sample/practice questions would be highly... (0 Replies)
Discussion started by: chrs0302
0 Replies

5. Solaris

VERITAS Storage Foundation 5.0

HI friends, i'm planning tot study VERITAS Storage Foundation 5.0 .but i didn't get the study meterial (pdf or URL link). Any one can help me to get the PDF . Rgds, Jay (4 Replies)
Discussion started by: rjay.com
4 Replies

6. Solaris

Veritas Storage Question

How do you get the total size of the LUNS currently online on a Solaris 10 server running Symantec Storage Foundation? (2 Replies)
Discussion started by: soupbone38
2 Replies

7. Filesystems, Disks and Memory

Veritas Storage Foundation

Hi. I've been working with UNIX/Linux for several years, but never in a VSF environment where I actually got to use any of it. I downloaded the basic package for free (Don't worry, Symantec now allows for this for limited use) and intend to try this out on Linux and Solaris (also not my... (2 Replies)
Discussion started by: mark54g
2 Replies

8. UNIX for Advanced & Expert Users

SDS to Veritas migration

...I have a situation where I disks that I mirrored using Solstice Disksuite now need mirroring under Veritas Volume manager...would anyone know the best way to go about 'un-mirroring' and then removing SDS? I can see references in /etc/vfstab and /etc/system that I guess would need... (2 Replies)
Discussion started by: silvaman
2 Replies
Login or Register to Ask a Question
vxiod(1M)																 vxiod(1M)

NAME
vxiod - start, stop, and report on Veritas Volume Manager I/O threads SYNOPSIS
vxiod vxiod [-f ] [set count] DESCRIPTION
The vxiod utility starts, stops, or reports on Veritas Volume Manager (VxVM) I/O kernel threads. An I/O thread provides a process context for performing I/O in VxVM. When the vxio module is loaded, 16 I/O threads are created, plus 2 threads per additional CPU for a system with more than 8 CPUs, up to a maximum of 64 threads. At least one I/O thread must be running while the vxio module is loaded, and the number of I/O threads cannot be forced to zero. When invoked with no arguments, vxiod prints the current number of I/O threads to the standard output. The number of threads that is required for handling I/O requests depends on the system load and usage. If volume recovery seems to proceed more slowly at times, it may be possible to improve its performance by increasing the number of I/O threads up to a maximum of 64. KEYWORDS
set When invoked with the set keyword, vxiod creates the number of I/O threads specified by count. If more volume I/O threads exist than are specified by count, the excess processes terminate. If more than the maximum number(64) are specified, the requested number is silently truncated to that maximum. OPTIONS
-f This option has no effect from release 5.0 onward. The number of I/O threads cannot be reduced to zero. EXIT CODES
The vxiod utility prints a diagnostic on the standard error, and exits if an error is encountered. If an I/O request occurs within a I/O thread, the state of that I/O request is not reflected in the exit status for vxiod. Otherwise, vxiod returns a non-zero exit status on error. Usage errors result in an exit status of 1 and a usage message. If the requested number of threads cannot be created, the exit status is 2, and the number of threads that were successfully started is reported. If any other error occurs, the exit status is 3. FILES
/dev/vx/iod The device used to report on and start volume I/O threads. NOTES
Veritas Volume Manager I/O threads cannot be killed directly through the use of signals. Depending on the operating system, VxVM I/O threads may not appear in the list of processes that is output by the ps command. The number of I/O threads that is currently running can be determined by running vxiod. SEE ALSO
fork(2), ps(1), vxconfigd(1M), vxdctl(1M), vxintro(1M), vxio(7), vxiod(7) VxVM 5.0.31.1 24 Mar 2008 vxiod(1M)