I am not able to figure out if the disk is in mirror or not (hardware RAID). c1t1d0s0 is the one, which I need to replace, as this one is in the failing state.
Code:
solaris-10-priv#df -h /export/u02
Filesystem size used avail capacity Mounted on
/dev/dsk/c1t1d0s0 275G 266G 6.4G 98% /export/u02
solaris-10-priv#echo | format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <Sun-STKRAIDINT-V1.0 cyl 17831 alt 2 hd 255 sec 63>
/pci@0/pci@0/pci@9/scsi@0/disk@0,0
1. c1t1d0 <Sun-STKRAIDINT-V1.0 cyl 36417 alt 2 hd 255 sec 63>
/pci@0/pci@0/pci@9/scsi@0/disk@1,0
2. c1t2d0 <Sun-STKRAIDINT-V1.0 cyl 36418 alt 2 hd 255 sec 126>
/pci@0/pci@0/pci@9/scsi@0/disk@2,0
Specify disk (enter its number): Specify disk (enter its number):
solaris-10-priv#iostat -En | grep Hard
c1t0d0 Soft Errors: 2 Hard Errors: 1 Transport Errors: 59
c1t1d0 Soft Errors: 0 Hard Errors: 342 Transport Errors: 0
c1t2d0 Soft Errors: 2 Hard Errors: 1 Transport Errors: 10
c0t0d0 Soft Errors: 2 Hard Errors: 0 Transport Errors: 0
solaris-10-priv#
solaris-10-priv#raidctl -l
Controller: 2
solaris-10-priv#raidctl -l 2
Controller Type Version
----------------------------------------------------------------
c2 LSI_1068E 1.27.00.00
solaris-10-priv#
raidctl on that disk doesn't work, which I thought should work
Code:
solaris-10-priv#raidctl -l c1t1d0
Controller device can not be found.
solaris-10-priv#
Please suggest.
Thanks
---------UPDATE--------------
Didn't realized, I was supposed to use "/opt/StorMan/arcconf getconfig 1"
I am good now :-)
Last edited by solaris_1977; 04-22-2020 at 05:52 PM..
These 2 Users Gave Thanks to solaris_1977 For This Post:
Thanks for the update.
These hardware RAIDs ship with their own software. I wonder if Solaris provides a general frontend where they can plug in. (Like fbconfig, it was a frontend command for most of the graphic adaptors.)
Dear All ,
we have hardware raid 1 implemented on Solaris Disks.
We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers.
Thanks...
Rj (7 Replies)
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.
We have 2 LDOM configured on this server and this server running on single disk.
#... (8 Replies)
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
hi all, will command metastats tell whether there is hardware layered raid ?
i intend to do patching and plug out one of the disks in case the one inside encountered issues. (1 Reply)
Hi,
I have a question. Do LiveUpgrade supports hardware raid?
How to choose the configuration of the system disk for Solaris 10 SPARC?
1st Hardware RAID-1 and UFS
2nd Hardware RAID-1 and ZFS
3rd SVM - UFS and RAID1
4th Software RAID-1 and ZFS
I care about this in the future to take... (1 Reply)
Hi,
I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1"
The System did come preinstalled as it comes from sun. I did not do much on it.
I booted system using boot cdrom -s
gave format... (6 Replies)
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)