I had power issue that affected a server, in which I had power ON the server SPARC T1-B3 running solaris 10.
After power on the system stops at ok prompt, them I issued the following commands:
Code:
{0} ok setenv auto-boot? false
auto-boot? = false
{0} ok reset-all
SPARC T3-1B, No Keyboard
Copyright (c) 1998, 2010, Oracle and/or its affiliates. All rights reserved.
OpenBoot 4.32.1, 65024 MB memory available, Serial #98354310.
Ethernet address 0:21:28:dc:c4:86, Host ID: 85dcc486.
{0} ok probe-scsi-all
/pci@400/pci@2/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0,1
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@2/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@1/pci@0/pci@7/pci@0/usb@0,2/hub@3/storage@2
Unit 0 Removable Read Only device AMI Virtual CDROM 1.00
/pci@400/pci@1/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0,1
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@1/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@1/pci@0/pci@2/LSI,sas@0
FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00
Target 9
Unit 0 Disk SEAGATE ST930003SSUN300G 0B70
SASDeviceName 5000c50039c1548b SASAddress 5000c50039c15489 PhyNum 0
Target a
Unit 0 Disk SEAGATE ST930003SSUN300G 0B70
SASDeviceName 5000c50039bdd4cb SASAddress 5000c50039bdd4c9 PhyNum 1
{0} ok
So I am not able to boot.
I found it very strange to have these errors because, all I had was a power failure to the blade, and I have managed to power on successfully the other blade on the same chassis
The thing I found strange is the FC cables there at the back of the chassis are only connected to the NetApp storage system, so why the system wont boot?, But a blade next to this one, does boot normaly..
ok printenv boot-device
boot-device = disk net
{0} ok
then I use the following procedure to change the boot device:
Code:
{0} ok setenv auto-boot? false
auto-boot? = false
{0} ok reset-all
SPARC T3-1B, No Keyboard
Copyright (c) 1998, 2010, Oracle and/or its affiliates. All rights reserved.
OpenBoot 4.32.1, 65024 MB memory available, Serial #98354310.
Ethernet address 0:21:28:dc:c4:86, Host ID: 85dcc486.
{0} ok devalias
screen /pci@400/pci@2/pci@0/pci@7/pci@0/display@0
mouse /pci@400/pci@1/pci@0/pci@7/pci@0/usb@0,1/device@2/mouse@1
rcdrom /pci@400/pci@1/pci@0/pci@7/pci@0/usb@0,2/hub@3/storage@2/disk@0
rkeyboard /pci@400/pci@1/pci@0/pci@7/pci@0/usb@0,1/device@2/keyboard@0
rscreen /pci@400/pci@2/pci@0/pci@7/pci@0/display@0:r1280x1024x60
net3 /niu@480/network@1
net2 /niu@480/network@0
net1 /pci@400/pci@2/pci@0/pci@2/network@0,1
net0 /pci@400/pci@2/pci@0/pci@2/network@0
net /pci@400/pci@2/pci@0/pci@2/network@0
disk3 /pci@400/pci@1/pci@0/pci@2/@0/disk@p3
disk2 /pci@400/pci@1/pci@0/pci@2/@0/disk@p2
disk1 /pci@400/pci@1/pci@0/pci@2/@0/disk@p1
disk0 /pci@400/pci@1/pci@0/pci@2/@0/disk@p0
disk /pci@400/pci@1/pci@0/pci@2/@0/disk@p0
rem /pci@400/pci@1/pci@0/pci@2/@0
virtual-console /virtual-devices@100/console@1
name aliases
{0} ok printenv boot-device
boot-device = disk0
{0} ok setenv boot-device /pci@400/pci@1/pci@0/pci@2/@0/disk@p0
boot-device = /pci@400/pci@1/pci@0/pci@2/@0/disk@p0
{0} ok printenv boot-device
boot-device = /pci@400/pci@1/pci@0/pci@2/@0/disk@p0
{0} ok boot
Boot device: /pci@400/pci@1/pci@0/pci@2/@0/disk@p0 File and args:
But I am not able to boot. I īve try other selections from the devalias command, but still not able to boot
------ Post updated at 12:32 PM ------
Hi
I have now run the following:
Code:
{0} ok probe-scsi-all
/pci@400/pci@2/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0,1
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@2/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@1/pci@0/pci@7/pci@0/usb@0,2/hub@3/storage@2
Unit 0 Removable Read Only device AMI Virtual CDROM 1.00
/pci@400/pci@1/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0,1
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@1/pci@0/pci@4/pci@0/pci@2/SUNW,qlc@0
QLogic QEM3572 Host Adapter FCode(SPARC): 3.06 08/19/09
ISP Firmware version 4.06.02
Fibre Channel Link down
Possible causes: No cable, incorrect connection mode or data rate
SFP state: 8Gb Present
/pci@400/pci@1/pci@0/pci@2/LSI,sas@0
FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00
Target 9
Unit 0 Disk SEAGATE ST930003SSUN300G 0B70
SASDeviceName 5000c50039c1548b SASAddress 5000c50039c15489 PhyNum 0
Target a
Unit 0 Disk SEAGATE ST930003SSUN300G 0B70
SASDeviceName 5000c50039bdd4cb SASAddress 5000c50039bdd4c9 PhyNum 1
{0} ok
the following action I beleive is to boot from one of those two disks... But how to identify them in devalias command
hi everone
i am experiencing disconnectivity from storage to My database machines. i have doubt on my FC cards in my sparc T4-2 machines. i want to know how should i check from my solaris that whether the cards are ok or not because once the disks get disconnect from SAN so it come back again but... (5 Replies)
Hi,
One of my Netra 240 went into hung state and I had to reboot it. I powered it off and tried booting it again but unsuccessful. It is not connected to SAN and have local disks. Not able to boot in failsafe mode too.
There are two disks of 72GB, both are mirrored in SVM. It complains about... (5 Replies)
Hello all,
Let me introduce about the context and my environment.
We have an AIX 6.1 system, it has 4 FC channels
/ > lsdev -Cc adapter | grep fcs
fcs0 Available 23-T1 Virtual Fibre Channel Client Adapter
fcs1 Available 23-T1 Virtual Fibre Channel Client Adapter
fcs2 Available 23-T1... (14 Replies)
We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice?
Thanks in advance. (1 Reply)
Hi ,
I have wrtitten a C program that issues USCSICMD ioctl call to the tape devices attached on solaris sparc 10. I was able to get the required information from all SCSI tape devices attached using the utility. But, whenever it is run on FC attached tape drives , the program returns an error... (0 Replies)
Hello,
Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter.
It is similar to virtual scsi adapter.
In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)