Adding new luns to mpxio config - showing up twice in format.


 
Thread Tools Search this Thread
Operating Systems Solaris Adding new luns to mpxio config - showing up twice in format.
# 1  
Old 06-05-2012
Adding new luns to mpxio config - showing up twice in format.

Hi,

I have a sun 440, it already has LUN's configured with MPXIO.

I just had more LUNS added, I did devfsadm and cfgadm -al, and they're showing up twice in "Format". Smilie


There are no new fiber cables or HBA's involved, same physical setup, just adding LUNS.

Aren't they supposed to get imported into MPXIO? Do I have to actually reboot for this? Or is there a command I'm missing?

Thanks for any help in advance!
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Adding a blank line in between two O/Ps in tabular format which gets received over email

Hi Guys, I am stuck in between and seeking help here. Requirement: A script that will run every morning which will connect to Mysql database and run the query to inform us about the holidays (it will also check if there were any holidays during last 2 business days). So the three queries are... (11 Replies)
Discussion started by: Sambit Sahu
11 Replies

2. Solaris

Drive is showing offline in the /var/adm/messages and shows "drive type unknown" in the format outpu

Hi, I am facing issue with one of the drive is solaris 10. it is showing offline in the messages file scsi: WARNING: /pci@2,600000/QLGC,qlc@0/fp@0,0/ssd@w5006016746e00b1b,0 (ssd0): drive offline genunix: WARNING: Page83 data not standards compliant DGC LUNZ 0430 ... (1 Reply)
Discussion started by: Prasanth T K
1 Replies

3. HP-UX

After adding new iscsi target port, still the session state of that target port is showing offline

Hi, I wanted to configure new iscsi port on HPUX system, i added the target port address and configured it, once done, went to array side and searched for that host iqn number , but was nt able to find the same, came to host, then when i ran "iscsiutil -pVS" command it gave me below result ... (0 Replies)
Discussion started by: Vinay Kumar D
0 Replies

4. Solaris

Mpathadm showing no paths to 1 lun, others luns are fine

Hi, I've noticed that mpathadm states that one of our luns has no active paths: /dev/rdsk/c6t60000970000298700009533031324333d0s2 Total Path Count: 4 Operational Path Count: 4 /dev/rdsk/c6t60000970000298700009533031333037d0s2 ... (3 Replies)
Discussion started by: badoshi
3 Replies

5. UNIX for Dummies Questions & Answers

Des/awk for change format and adding integers in a column of data?

Greetings! I need a quick way to change the format in a table of data Here is an example of the input: 10 72 Value=177 VDB=0.0245 Value4=0,0,171,0 10 274 Value=238 VDB=0.0433 Value4=29,0,205,0 10 312 Value=222 VDB=0.0384 Value4=8,0,190,19 10 540 Value=405 VDB=0.0391 Value4=13,30,153,195... (3 Replies)
Discussion started by: Twinklefingers
3 Replies

6. Red Hat

Adding LUNs to system

Hi guys I have been asked for the following: SMI Oracle database PTP10 Oracle 10g RAC on usdfslprac4 and usdfslprac5 Linux boxes is reaching its space limit. It is just 20 GB away from being completely out of disk space. And then database will stop working and SMI system hence will be impacted.... (0 Replies)
Discussion started by: 300zxmuro
0 Replies

7. Solaris

MPXIO

Hi Kudo, I wanna to know that how can I do mpxio device name to os native name mapping without using stmsboot -L I tried everything still not able to got the solution till I able to get these o/p here is native disk info as well physical wat is the logical OS name of the disk ... (1 Reply)
Discussion started by: tarunn.dubeyy
1 Replies

8. Filesystems, Disks and Memory

vxdisk list output showing extra LUNs

hi fren i am facing this problem i have sun 6140 storage 30 volumes bt my vxdisk list output is showing 37 disk which shd nt b there has neone faced this proble earlier vxdiks list output is like this SUN6140-2_0 auto - - online c4t201700A0B84853C0d2s2 SUN6140-2_1 auto - - online... (13 Replies)
Discussion started by: bond_ankur
13 Replies

9. Shell Programming and Scripting

converting config file to csv format

Hello, For 2 days now i've been searching for a solution to this. I am now beginning to doubt this is even possible. It's even harder when you don't know how to search for it. (which keywords generate enough relevancy etc..) I need to parse a config file to generate a CSV file in return. It... (7 Replies)
Discussion started by: zer0dvide
7 Replies
Login or Register to Ask a Question
ifc_disable_mgmt_lun(5) 					File Formats Manual					   ifc_disable_mgmt_lun(5)

NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management luns is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. SEE ALSO