SVM ISSUE...


 
Thread Tools Search this Thread
Operating Systems Solaris SVM ISSUE...
# 1  
Old 11-30-2011
SVM ISSUE...

Dear All,

I face some errors in SVM.Need help.

Actually couple of days ago i got a call from one of the customer mentioning that one of the sub-mirror was in Need maintance state. So we replaced that disk. After Replacing the disk it comes back to "Okay" State.

But the Error are coming im messages file.

Please have a look to the below logs.

Problem Reported By Customer:

d96: Mirror
Submirror 0: d94
State: Okay
Submirror 1: d95
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 130262976 blocks (62 GB)
d94: Submirror of d96
State: Okay
Size: 130262976 blocks (62 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s5 0 No Okay Yes

d95: Submirror of d96
State: Needs maintenance
Invoke: metareplace d96 c1t1d0s5 <new device>
Size: 130262976 blocks (62 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t1d0s5 0 No Maintenance Yes


After Disk Replacement (log) :

d96: Mirror
Submirror 0: d94
State: Okay
Submirror 1: d95
State: Okay
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 130262976 blocks (62 GB)
d94: Submirror of d96
State: Okay
Size: 130262976 blocks (62 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s5 0 No Okay Yes

d95: Submirror of d96
State: Okay
Size: 130262976 blocks (62 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t1d0s5 0 No Okay Yes


But some errors are coming in msg files. The logs are as follows.

Nov 30 02:52:30 bhvuno Error for Command: read(10) Error Level: Retryable
Nov 30 02:52:30 bhvuno scsi: [ID 107833 kern.notice] Requested Block: 112421496 Error Block: 112421496
Nov 30 02:52:30 bhvuno scsi: [ID 107833 kern.notice] Vendor: HITACHI Serial Number: 0338W1CKWS
Nov 30 02:52:30 bhvuno scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Nov 30 02:52:30 bhvuno scsi: [ID 107833 kern.notice] ASC: 0x29 (<vendor unique code 0x29>), ASCQ: 0x3, FRU: 0x0
Nov 30 02:52:38 bhvuno scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000000870148b2,0 (ssd2):
Nov 30 02:52:38 bhvuno Error for Command: read(10) Error Level: Fatal
Nov 30 02:52:38 bhvuno scsi: [ID 107833 kern.notice] Requested Block: 22246956 Error Block: 22247010
Nov 30 02:52:38 bhvuno scsi: [ID 107833 kern.notice] Vendor: HITACHI Serial Number: 0338W1CKWS
Nov 30 02:52:38 bhvuno scsi: [ID 107833 kern.notice] Sense Key: Media Error
Nov 30 02:52:38 bhvuno scsi: [ID 107833 kern.notice] ASC: 0x11 (<vendor unique code 0x11>), ASCQ: 0x2, FRU: 0x0
Nov 30 02:52:38 bhvuno md_stripe: [ID 641072 kern.warning] WARNING: md: d95: read error on /dev/dsk/c1t1d0s5
Nov 30 02:52:38 bhvuno md_mirror: [ID 842313 kern.info] NOTICE: md: d95: B_FAILFAST I/O retry
Nov 30 02:52:39 bhvuno scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000000870148b2,0 (ssd2):
Nov 30 02:52:39 bhvuno Error for Command: read(10) Error Level: Retryable
Nov 30 02:52:39 bhvuno scsi: [ID 107833 kern.notice] Requested Block: 22246956 Error Block: 22247010
Nov 30 02:52:39 bhvuno scsi: [ID 107833 kern.notice] Vendor: HITACHI Serial Number: 0338W1CKWS
Nov 30 02:52:39 bhvuno scsi: [ID 107833 kern.notice] Sense Key: Media Error
Nov 30 02:52:39 bhvuno scsi: [ID 107833 kern.notice] ASC: 0x11 (<vendor unique code 0x11>), ASCQ: 0x2, FRU: 0x0
Nov 30 02:52:39 bhvuno md_mirror: [ID 726726 kern.info] NOTICE: md: d95: spurious error; B_FAILFAST I/O retry succeeded
Nov 30 02:54:15 bhvuno scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000000870148b2,0 (ssd2):
Nov 30 02:54:15 bhvuno Error for Command: read(10) Error Level: Retryable
Nov 30 02:54:15 bhvuno scsi: [ID 107833 kern.notice] Requested Block: 22719168 Error Block: 22719170
Nov 30 02:54:15 bhvuno scsi: [ID 107833 kern.notice] Vendor: HITACHI Serial Number: 0338W1CKWS
Nov 30 02:54:15 bhvuno scsi: [ID 107833 kern.notice] Sense Key: Media Error
Nov 30 02:54:15 bhvuno scsi: [ID 107833 kern.notice] ASC: 0x11 (<vendor unique code 0x11>), ASCQ: 0x2, FRU: 0x0



please help me, what would be outcome of this ?

Thank you all.
# 2  
Old 11-30-2011
which Solaris version live in your server?

which is the SVM version?
# 3  
Old 11-30-2011
What does this output:
Code:
iostat -xn ssd2

# 4  
Old 12-03-2011
Quote:
Originally Posted by cerber0
which Solaris version live in your server?

which is the SVM version?

Solaris 5.9 installed in the server.
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Solaris

Fsck with SVM

Hello I want to ask that how to mount and run fsck in SVM disk.In my scenario if i have to disks c0t0d0 and c0t1d0 these two disks are in Mirroring (raid1) if i want to run fsck on the disks than below are the right steps? ok boot cdrom -s mount /dev/dsk/c0t0d0s0 /a cd /a fsck... (3 Replies)
Discussion started by: jhonnybravo
3 Replies

2. Solaris

SVM Creation

Hello, I recently patched my Solaris 10 box and found out that few of the apps are not working. Fortunately, I had detached the mirroring prior to patching, so I just booted into my secondary disk and found that my apps are working.... The problem is this was way back in last month....see... (14 Replies)
Discussion started by: zigi_p5
14 Replies

3. UNIX for Advanced & Expert Users

What is interlace value in SVM?

Hi All, I want to know what is the Interlace value in SVM and what is the need of this ? regards, prashant (1 Reply)
Discussion started by: prashant2507198
1 Replies

4. UNIX for Advanced & Expert Users

SVM

How to list out multiple Disk sets in SVM # metaset -s <disksetname> --- This will list out only one diskset but I need a list of disk sets configured for the node. Is there any command,please let me know ... Thanks in advance. (1 Reply)
Discussion started by: pramath
1 Replies

5. Solaris

Problem with SVM

HI, I added by error to a submirror some disks : metattach d53 c2t90d0s0 c2t90d1s0 ... instead of doing a stripe by disk (like that) : metattach d53 c2t90d0s0 metattach d53 c2t90d1s0 .. then, I did a growfs -M to expand FS and the size isn't correct. I tried to launch a... (1 Reply)
Discussion started by: phil.nakache
1 Replies

6. UNIX for Dummies Questions & Answers

SVM doubt

i have taken two separate disk A and B created 4 slices in each A b s4 s4 s5 s5 s6 s6 s7 s7 took slices s4 of A and slice s6 0f B ---created a meta device d0 took slices s4 of B and slice s6 0f A---created a meta device d1 created main mirror d2 using d0... (1 Reply)
Discussion started by: vivek_ng
1 Replies

7. Solaris

SVM question

I am trying to set up a new server. It has 8 HD's in it. I am using 2 for the system disk. IE set one up mirror to the other. I am using the other 6 as data disks. For those I want to concat 3 together, mirror to the other 3 (also concated together of course) and then make various soft... (7 Replies)
Discussion started by: NewSolarisAdmin
7 Replies

8. Solaris

SVM, mirroring

Really sorry for the long posting. But i would really want to clear all the doubts. I have 2 disk c0t0d0 & c0t1d0, i wanted to mirror c0t1d0 (mirror) to c0t0d0 (main). Creating state database replica: metadb -a -c3 -f c0t0d0s7 ... (3 Replies)
Discussion started by: beginningDBA
3 Replies

9. Solaris

Change the name in SVM

gurus, i have configured the LUN's in solaris 10.after labeled the disk,i have added the disk into one of the soft partition using metattach d0 c5t1000d10s6.actully before that i should confiure the powermt and than i should have add metattch d0 emcpowerc2.i forget to do that and increased... (0 Replies)
Discussion started by: rjay.com
0 Replies

10. Solaris

How do you remove a RAID 5 under SVM?

I have this setup, i can only find docs to unmirror a raid 1 set, how do you get rid of a raid 5 set? the same way? metadetach and metaclear? d8: RAID State: Okay Interlace: 32 blocks Size: 142245693 blocks (67 GB) Original device: Size: 142247872 blocks (67 GB) ... (2 Replies)
Discussion started by: BG_JrAdmin
2 Replies