Disk Storage Need to Add more Disk


 
Thread Tools Search this Thread
Operating Systems Solaris Disk Storage Need to Add more Disk
# 1  
Old 11-10-2010
Disk Storage Need to Add more Disk

Hi,

Anyone can help me, just want to confirm, if possible adding a disk storage that we have a RAWDATA with +ASM in our database. If possible, what would you recommend "workaround used" from us to do and the preparation. And also how long the downtime will take.

Our disk continuous to grow, need to add more disk storage in our "Sun StorageTek 3510 FC Array".

Storage having the following above;

Database : Oracle10g release 10.2.0.3
OS : SUN Solaris 10
Number of Nodes and Oracle SID Mapping : 2 instances "db01 and db02" using rawdata with +asm

Thanks in Advance;
FP

Last edited by DukeNuke2; 11-10-2010 at 07:02 AM..
Login or Register to Ask a Question

Previous Thread | Next Thread

6 More Discussions You Might Find Interesting

1. Linux

Move OS to storage disk

Hi We have RHEL 7.3 running from local disk and we want to move it to storage. I am unable to find any proper procedure to do this activity. Please help. (4 Replies)
Discussion started by: powerAIX
4 Replies

2. Red Hat

storage disk details

Hi, We have a OEL5.7 installed and which has a storage attached on it. While running application it shows poor performance for Disk IO "dm-0" Now the question is how do I find what exactly is "dm-0" # iostat Linux 2.6.32-100.23.1.el5 03/10/2012 avg-cpu: %user %nice %system... (9 Replies)
Discussion started by: shrshah64
9 Replies

3. Shell Programming and Scripting

Age of file in storage / disk

Hello all, Below is scripts to find the file following by: 30 days <- How many total file space within 30 days and not quantity 90 days 120 days 1 year From here also I can get data space to put on PIE Chart. Following this scripts can I do some enhance from this scripts like do... (1 Reply)
Discussion started by: sheikh76
1 Replies

4. Solaris

A1000 Disk storage array

I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why? What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies

5. Solaris

( VxVM ) How to add the removed disk back to previous disk group

Previously , i remove the disk by #vxdg -g testdg -k rmdisk testdg02 But i got error when i -k adddisk bash-2.03# vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online invalid c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies

6. Solaris

3511 storage disk not detected

I need help in this :confused: there was a disk failure in one logical drive, and there was a hot spare, once the disk failed i removed it and the hot spare took its place. now after I got a new disk, I added it in the place of the failed disk (slot #2), but the storage is not showing me any... (3 Replies)
Discussion started by: Sun Fire
3 Replies
Login or Register to Ask a Question
hpialarms(1)							      OpenHPI							      hpialarms(1)

NAME
hpialarms - A openhpi sample application that shows "Alarm Control" management instruments SYNOPSIS
hpialarms [-a -b -c -i -m -n -p -o -x] DESCRIPTION
hpialarms walks the RPT (Resource Present Table) for resouces that have "Alarm Control" management instruments (SAHPI_CTRL_LED). OPTIONS
-c1 sets Critical Alarm on -c0 sets Critical Alarm off -m1 sets Major Alarm on -m0 sets Major Alarm off -n1 sets Minor Alarm on -n0 sets Minor Alarm off -p1 sets Power Alarm on -p0 sets Power Alarm off -i5 sets Chassis ID on for 5 sec -i0 sets Chassis ID off -a1 sets Disk A fault on -a0 sets Disk A fault off -b1 sets Disk B fault on -b0 sets Disk B fault off -d[byte] sets raw Alarm byte -o sets all Alarms off -x show eXtra debug messages SAMPLE OUTPUT
hpialarmpanel ver 0.6 RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0 rptentry[0] resourceid=1 tag: Mullins RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON RDR[46]: ctltype=0:0 oem=0 Cold Reset Control RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off SEE ALSO
AUTHORS