02-24-2009
15,
0
Join Date: Dec 2008
Last Activity: 30 April 2011, 1:25 AM EDT
Posts: 15
Thanks Given: 0
Thanked 0 Times in 0 Posts
Hello dear, after the resync now the system is showing that all hdds are good but its shifted all data to hot spare hdd. Now, tell me how can I add that old hdd again in that raid 5 and can use hot spare hdd as hot spare.
I am pasting below the details of metastat command:
root@ugkpdb01 # metastat -i d5
d5: RAID
State: Okay
Hot spare pool: hsp000
Interlace: 32 blocks
Size: 1757741056 blocks (838 GB)
Original device:
Size: 1757762112 blocks (838 GB)
Device Start Block Dbase State Reloc Hot Spare
c6t0d0s0 330 No Okay Yes
c6t1d0s0 330 No Okay Yes c6t4d0s0
c6t2d0s0 330 No Okay Yes
c6t3d0s0 330 No Okay Yes
Device Relocation Information:
Device Reloc Device ID
c6t0d0 Yes id1,sd@SFUJITSU_MAW3300NCSUN300G000719D02TCT____DA20P7502TCT
c6t1d0 Yes id1,sd@SFUJITSU_MAW3300NCSUN300G000719D02TCS____DA20P7502TCS
c6t4d0 Yes id1,sd@SFUJITSU_MAW3300NCSUN300G000720D02TDU____DA20P7502TDU
c6t2d0 Yes id1,sd@SFUJITSU_MAW3300NCSUN300G000720D02TDS____DA20P7502TDS
c6t3d0 Yes id1,sd@SFUJITSU_MAW3300NCSUN300G000720D02TDJ____DA20P7502TDJ
root@ugkpdb01 #
will it be
#metareplace d5 c6t1d0s0
and what else? waiting for the prompt response. Thanks