Replacing mirrors with different size drives


 
Thread Tools Search this Thread
Operating Systems Solaris Solaris BigAdmin RSS Replacing mirrors with different size drives
# 1  
Old 01-23-2009
Replacing mirrors with different size drives

Thread discussing question "I need to know if there is a specific procedure for replacing a failed drive in a mirror with a larger drive and still maintain the mirror integrity?"

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Solaris

Zpool with 3 2-way mirrors in a pool

I have a single zpool with 3 2-way mirrors ( 3 x 2 way vdevs) it has a degraded disk in mirror-2, I know I can suffer a single drive failure, but looking at this how many drive failures can this suffer before it is no good? On the face of it, I thought that I could lose a further 2 drives in each... (4 Replies)
Discussion started by: fishface
4 Replies

2. Solaris

Oneway mirrors

All, One-way mirror. Elements of the concat in Last-errd state. What would be the best way to correct it? metastat -s db2test -pc db2test/d220 p 5.0GB db2test/d200 db2test/d219 p 5.0GB db2test/d200 db2test/d218 p 5.0GB db2test/d200 db2test/d217 p 30GB db2test/d200... (0 Replies)
Discussion started by: ossupport55
0 Replies

3. Solaris

Help with attaching mirrors

Hi Guys, I need a help with attaching the sub mirrors as it keep throwing errors. I have done solaris live upgrade and it was succesful but it keeps throwing error only for root (s0) and swap (s1)when i try to attach them. For rest of the partitions for slices 3,4,5 on target 1 are able to... (4 Replies)
Discussion started by: phanidhar6039
4 Replies

4. Linux

[Errno 256] No more mirrors to try.

Dear all, CentOS 6 After executing "yum update -y" command I am facing this error. Please help me out. thanks in advance. Full error & error code is given as follow: ... (7 Replies)
Discussion started by: saqlain.bashir
7 Replies

5. Linux

Additional mirrors on centos

How can I add additional mirrors to my CENTOS distro, according to this page AdditionalResources/Repositories - CentOS Wiki there are few fedora project repositories I'd like to add any of them but I don't know how? Thank you in advance (0 Replies)
Discussion started by: c0mrade
0 Replies

6. Solaris

both mirrors in needs maintenance state.

Hi, Ii am facing the belwo problem: d50: Mirror Submirror 0: d30 State: Needs maintenance Submirror 1: d40 State: Needs maintenance Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 212176648 blocks (101 GB) d30:... (3 Replies)
Discussion started by: sag71155
3 Replies

7. Shell Programming and Scripting

how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX

hi how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX? thanks (0 Replies)
Discussion started by: nokia1100
0 Replies

8. Solaris

DiskSuite: Breaking mirrors.

Ok, so I have a remote system (7 states away) that's using SDS to manage the two 18 gig disks. /, swap, /var, /home, and /opt. The mirroring procedure I created uses installboot to ensure there's a bootblk on both disks of an SDS mirror. The system has a problem booting (can't write to... (21 Replies)
Discussion started by: BOFH
21 Replies

9. UNIX for Advanced & Expert Users

What's the easiest way to display system cpu, memory, # drives/size ??

I am looking for the easiest and most generic way to determine: System model/class Number of cpu's Clock speed of cpu's (ie 550 MHz) Total Physical Memory (not virtual) Number of Drives/Drive Size Thanks in advance, (4 Replies)
Discussion started by: eyounes
4 Replies
Login or Register to Ask a Question
MLX(4)                                                     BSD Kernel Interfaces Manual                                                     MLX(4)

NAME
mlx -- Mylex DAC-family RAID driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device mlx Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): mlx_load="YES" DESCRIPTION
The mlx driver provides support for Mylex DAC-family PCI to SCSI RAID controllers, including versions relabeled by Digital/Compaq. HARDWARE
Controllers supported by the mlx driver include: o Mylex DAC960P o Mylex DAC960PD / DEC KZPSC (Fast Wide) o Mylex DAC960PDU o Mylex DAC960PL o Mylex DAC960PJ o Mylex DAC960PG o Mylex DAC960PU / DEC PZPAC (Ultra Wide) o Mylex AcceleRAID 150 (DAC960PRL) o Mylex AcceleRAID 250 (DAC960PTL1) o Mylex eXtremeRAID 1100 (DAC1164P) o RAIDarray 230 controllers, aka the Ultra-SCSI DEC KZPAC-AA (1-ch, 4MB cache), KZPAC-CA (3-ch, 4MB), KZPAC-CB (3-ch, 8MB cache) All major firmware revisions (2.x, 3.x, 4.x and 5.x) are supported, however it is always advisable to upgrade to the most recent firmware available for the controller. Compatible Mylex controllers not listed should work, but have not been verified. DIAGNOSTICS
Controller initialisation phase mlx%d: controller initialisation in progress... mlx%d: initialisation complete The controller firmware is performing/has completed initialisation. mlx%d: physical drive %d:%d not responding The drive at channel:target is not responding; it may have failed or been removed. mlx%d: spinning up drives... Drive startup is in progress; this may take several minutes. mlx%d: configuration checksum error The array configuration has become corrupted. mlx%d: mirror race recovery in progress mlx%d: mirror race on a critical system drive mlx%d: mirror race recovery failed These error codes are undocumented. mlx%d: physical drive %d:%d COD mismatch Configuration data on the drive at channel:target does not match the rest of the array. mlx%d: system drive installation aborted Errors occurred preventing one or more system drives from being configured. mlx%d: new controller configuration found The controller has detected a configuration on disk which supersedes the configuration in its nonvolatile memory. It will reset and come up with the new configuration. mlx%d: FATAL MEMORY PARITY ERROR Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. mlx%d: unknown firmware initialisation error %x:%x:%x An unknown error occurred during initialisation; it will be ignored. Driver initialisation/shutdown phase: mlx%d: can't allocate scatter/gather DMA tag mlx%d: can't allocate buffer DMA tag mlx%d: can't allocate s/g table mlx%d: can't make initial s/g list mapping mlx%d: can't make permanent s/g list mapping mlx%d: can't allocate interrupt mlx%d: can't set up interrupt A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. mlx%d: error fetching drive status The current status of all system drives could not be fetched; attachment of system drives will be aborted. mlx%d: device_add_child failed mlx%d: bus_generic_attach returned %d Creation of the system drive instances failed; attachment of one or more system drives may have been aborted. mlxd%d: detaching... The indicated system drive is being detached. mlxd%d: still open, can't detach The indicated system drive is still open or mounted; the controller cannot be detached. mlx%d: flushing cache... The controller cache is being flushed prior to detach or shutdown. Operational diagnostics: mlx%d: ENQUIRY failed - %s mlx%d: ENQUIRY2 failed mlx%d: ENQUIRY_OLD failed mlx%d: FLUSH failed - %s mlx%d: CHECK ASYNC failed - %s mlx%d: REBUILD ASYNC failed - %s mlx%d: command failed - %s The controller rejected a command for the reason given. mlx%d: I/O beyond end of unit (%u,%d > %u) mlx%d: I/O error - %s An I/O error was reported by the controller. mlx%d: periodic enquiry failed - %s An attempt to poll the controller for status failed for the reason given. mlx%d: mlx_periodic_enquiry: unknown command %x The periodic status poll has issued a command which has become corrupted. mlxd%d: drive offline mlxd%d: drive online mlxd%d: drive critical The system disk indicated has changed state. mlx%d: physical drive %d:%d reset mlx%d: physical drive %d:%d killed %s mlx%d: physical drive %d:%d error log: sense = %d asc = %x asq = %x mlx%d: info %4D csi %4D The drive at channel:target has been reset, killed for the given reason, or experienced a SCSI error. mlx%d: unknown log message type %x mlx%d: error reading message log - %s An error occurred while trying to read the controller's message log. mlxd%d: consistency check started mlx%d: consistency check completed A user-initiated consistency check has started/completed. mlx%d: drive rebuild started for %d:%d mlx%d: drive rebuild completed A user-initiated physical drive rebuild has started/completed. mlx%d: background check/rebuild operation started mlx%d: background check/rebuild operation completed An automatic system drive consistency check or physical drive rebuild has started/completed. mlx%d: channel %d pausing for %d seconds mlx%d: channel %d resuming mlx%d: pause command failed - %s mlx%d: pause failed for channel %d mlx%d: resume command failed - %s mlx%d: resume failed for channel %d Controller/channel pause operation notification. (Channel pause is not currently supported on any controller.) mlx%d: controller wedged (not taking commands) The controller is not responding to attempts to submit new commands. mlx%d: duplicate done event for slot %d mlx%d: done event for nonbusy slot %d Corruption has occurred in either the controller's onboard list of commands or in the driver. SEE ALSO
mlxcontrol(8) AUTHORS
The mlx driver was written by Michael Smith <msmith@FreeBSD.org>. This manual page was written by Jeroen Ruigrok van der Werven <asmodai@FreeBSD.org> and Michael Smith <msmith@FreeBSD.org>. BUGS
The driver does not yet support EISA adapters. The DEC KZPSC has insufficient flash ROM to hold any reasonably recent firmware. This has caused problems for this driver. The driver does not yet support the version 6.x firmware as found in the AcceleRAID 352 and eXtremeRAID 2000 and 3000 products. BSD August 10, 2004 BSD