Replacing mirrors with different size drives


 
Thread Tools Search this Thread
Operating Systems Solaris Solaris BigAdmin RSS Replacing mirrors with different size drives
# 1  
Old 01-23-2009
Replacing mirrors with different size drives

Thread discussing question "I need to know if there is a specific procedure for replacing a failed drive in a mirror with a larger drive and still maintain the mirror integrity?"

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Solaris

Zpool with 3 2-way mirrors in a pool

I have a single zpool with 3 2-way mirrors ( 3 x 2 way vdevs) it has a degraded disk in mirror-2, I know I can suffer a single drive failure, but looking at this how many drive failures can this suffer before it is no good? On the face of it, I thought that I could lose a further 2 drives in each... (4 Replies)
Discussion started by: fishface
4 Replies

2. Solaris

Oneway mirrors

All, One-way mirror. Elements of the concat in Last-errd state. What would be the best way to correct it? metastat -s db2test -pc db2test/d220 p 5.0GB db2test/d200 db2test/d219 p 5.0GB db2test/d200 db2test/d218 p 5.0GB db2test/d200 db2test/d217 p 30GB db2test/d200... (0 Replies)
Discussion started by: ossupport55
0 Replies

3. Solaris

Help with attaching mirrors

Hi Guys, I need a help with attaching the sub mirrors as it keep throwing errors. I have done solaris live upgrade and it was succesful but it keeps throwing error only for root (s0) and swap (s1)when i try to attach them. For rest of the partitions for slices 3,4,5 on target 1 are able to... (4 Replies)
Discussion started by: phanidhar6039
4 Replies

4. Linux

[Errno 256] No more mirrors to try.

Dear all, CentOS 6 After executing "yum update -y" command I am facing this error. Please help me out. thanks in advance. Full error & error code is given as follow: ... (7 Replies)
Discussion started by: saqlain.bashir
7 Replies

5. Linux

Additional mirrors on centos

How can I add additional mirrors to my CENTOS distro, according to this page AdditionalResources/Repositories - CentOS Wiki there are few fedora project repositories I'd like to add any of them but I don't know how? Thank you in advance (0 Replies)
Discussion started by: c0mrade
0 Replies

6. Solaris

both mirrors in needs maintenance state.

Hi, Ii am facing the belwo problem: d50: Mirror Submirror 0: d30 State: Needs maintenance Submirror 1: d40 State: Needs maintenance Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 212176648 blocks (101 GB) d30:... (3 Replies)
Discussion started by: sag71155
3 Replies

7. Shell Programming and Scripting

how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX

hi how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX? thanks (0 Replies)
Discussion started by: nokia1100
0 Replies

8. Solaris

DiskSuite: Breaking mirrors.

Ok, so I have a remote system (7 states away) that's using SDS to manage the two 18 gig disks. /, swap, /var, /home, and /opt. The mirroring procedure I created uses installboot to ensure there's a bootblk on both disks of an SDS mirror. The system has a problem booting (can't write to... (21 Replies)
Discussion started by: BOFH
21 Replies

9. UNIX for Advanced & Expert Users

What's the easiest way to display system cpu, memory, # drives/size ??

I am looking for the easiest and most generic way to determine: System model/class Number of cpu's Clock speed of cpu's (ie 550 MHz) Total Physical Memory (not virtual) Number of Drives/Drive Size Thanks in advance, (4 Replies)
Discussion started by: eyounes
4 Replies
Login or Register to Ask a Question
array-info(1)															     array-info(1)

NAME
array-info - check the status of a HP (Compaq) SmartArray controller SYNOPSIS
array-info -d array_device_path [-a|-l|-A|-c|-s|-L|-h] DESCRIPTION
Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the con- troller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive. OPTIONS
--device | -d Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1 --all-drives | -a Show informations about all drives --logical drive | -l Show informations about selected logical drive --show-ctrl | -c Show informations about controller --show-logical | -L Show informations about logical drives --show-physical | -p Show physical device informations --show-status | -s Show status of logical drives --show-all | -A Show all informations --version | -V Show version -h Show help about options COPYRIGHT
This manual page was written by Raphael Pinson <<raphink@ubuntu.com>>. Permission is granted to copy, distribute and/or modify this docu- ment under the terms of the GNU General Public License, Version 2 or any later version published by the Free Software Foundation. 2006-12-15 array-info(1)