1. Solaris
I have a single zpool with 3 2-way mirrors ( 3 x 2 way vdevs) it has a degraded disk in mirror-2, I know I can suffer a single drive failure, but looking at this how many drive failures can this suffer before it is no good? On the face of it, I thought that I could lose a further 2 drives in each... (4 Replies)
Discussion started by: fishface
4 Replies
2. Solaris
All,
One-way mirror. Elements of the concat in Last-errd state. What would be the best way to correct it?
metastat -s db2test -pc
db2test/d220 p 5.0GB db2test/d200
db2test/d219 p 5.0GB db2test/d200
db2test/d218 p 5.0GB db2test/d200
db2test/d217 p 30GB db2test/d200... (0 Replies)
Discussion started by: ossupport55
0 Replies
3. Solaris
Hi Guys,
I need a help with attaching the sub mirrors as it keep throwing errors.
I have done solaris live upgrade and it was succesful but it keeps throwing error only for root (s0) and swap (s1)when i try to attach them.
For rest of the partitions for slices 3,4,5 on target 1 are able to... (4 Replies)
Discussion started by: phanidhar6039
4 Replies
4. Linux
Dear all,
CentOS 6
After executing "yum update -y" command I am facing this error. Please help me out.
thanks in advance. Full error & error code is given as follow:
... (7 Replies)
Discussion started by: saqlain.bashir
7 Replies
5. Linux
How can I add additional mirrors to my CENTOS distro, according to this page AdditionalResources/Repositories - CentOS Wiki there are few fedora project repositories I'd like to add any of them but I don't know how?
Thank you in advance (0 Replies)
Discussion started by: c0mrade
0 Replies
6. Solaris
Hi,
Ii am facing the belwo problem:
d50: Mirror
Submirror 0: d30
State: Needs maintenance
Submirror 1: d40
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 212176648 blocks (101 GB)
d30:... (3 Replies)
Discussion started by: sag71155
3 Replies
7. Shell Programming and Scripting
hi
how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX?
thanks (0 Replies)
Discussion started by: nokia1100
0 Replies
8. Solaris
Ok, so I have a remote system (7 states away) that's using SDS to manage the two 18 gig disks. /, swap, /var, /home, and /opt.
The mirroring procedure I created uses installboot to ensure there's a bootblk on both disks of an SDS mirror.
The system has a problem booting (can't write to... (21 Replies)
Discussion started by: BOFH
21 Replies
9. UNIX for Advanced & Expert Users
I am looking for the easiest and most generic way
to determine:
System model/class
Number of cpu's
Clock speed of cpu's (ie 550 MHz)
Total Physical Memory (not virtual)
Number of Drives/Drive Size
Thanks in advance, (4 Replies)
Discussion started by: eyounes
4 Replies
MLXCONTROL(8) BSD System Manager's Manual MLXCONTROL(8)
NAME
mlxcontrol -- Mylex DAC-family RAID management utility
SYNOPSIS
mlxcontrol <command> [args]
mlxcontrol status [-qv] [drive]
mlxcontrol rescan controller [controller ...]
mlxcontrol detach drive [drive ...]
mlxcontrol detach -a
mlxcontrol check drive
mlxcontrol config controller
mlxcontrol help command
DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver.
Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the
unit number of the drive. Do not specify the path to a device node.
status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives,
otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa-
tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives
are critical and 2 if one or more are offline.
rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver
initialisation). If the -a flag is supplied, rescan all controllers in the system.
detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the
-a flag is supplied, detach all system drives from the nominated controller.
check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system
drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the
check.
rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on
the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one
rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild.
config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system
drives from a configuration in a future release.
help Print usage information for command.
AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>.
BUGS
The config command does not yet support modifying system drive configuration.
Error log extraction is not yet supported.
BSD
April 10, 2000 BSD