DataCenter Diagram


 
Thread Tools Search this Thread
Operating Systems Solaris Solaris BigAdmin RSS DataCenter Diagram
# 1  
Old 09-18-2008
DataCenter Diagram

Quickly create diagram of server showing correct cabling requirements. Use to guide engineers to cable server correctly or test correct cable etc.

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

7 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Venn diagram results using awk

Hi, I have the following files 1.txt a 10 b 11 c 12 d 13 e 14 f 15 g 16 h 17 i 18 j 19 k 20 2.txt a 21 b 22 (15 Replies)
Discussion started by: jacobs.smith
15 Replies

2. Shell Programming and Scripting

Request to checkVenn diagram issue solve by Unix programm

Hello Any Unix programm can help me to solve thsi issue: I have 2 venn digrams please checke the attached file for pictures of venn diagram for eg red is A yellow is B and green is C..Please see attached file for Venn diagrams In one ..... I have 3 data set A , B and C Venn diagram... (0 Replies)
Discussion started by: manigrover
0 Replies

3. Hardware

hardware diagram / database

Hi - we are looking for a (hopefully free/opensource) solution for diagramming our rack/hardware configuration. the rack solution seems easier to find than the hardware piece. i.e. on our IBM 770 with two CEC's, a method of noting what hardware points to what... for example, on the primary CEC,... (0 Replies)
Discussion started by: TinWalrus
0 Replies

4. Shell Programming and Scripting

Parse Log & Create Flow Diagram - Ideas/Tools

Hi, I would like to develop a script which parses the log file and generates a flow diagram ( graphical display ). We have an application, for understanding the sequence of functions call made, we have an debug line at "ENTRY/EXIT" of function. I have a small log parsing script which grep the... (2 Replies)
Discussion started by: ennstate
2 Replies

5. AIX

Set up a Datacenter with Power System

Can u please help me in knowing the details of the servers needed, FIBRE CABLES, HA softwares, VIO Softwares and other details. I googled through out and couldnt get a clear idea of it. Please help me (6 Replies)
Discussion started by: Sounddappan
6 Replies

6. UNIX for Advanced & Expert Users

Process diagram for 50+ unix scripts

Can someone point me to a good book for drawing a process diagram for 50+ unix scripts? The scripts run at different frequencies, and do everything from putting and getting data via FTP, to database I/O, to checking disk space ... etc. (0 Replies)
Discussion started by: tomstone_98
0 Replies

7. UNIX for Advanced & Expert Users

extracting info from Unix database to construct a visual diagram

Ok heres the situation, We use Solaris 8 at work with Sybase for the db. I need to be able to easily create visual diagrams of some of our more complex systems. I've been using Visio which is such a manual process and takes a while. I was thinking maybe using Visio somehow in conjunction... (0 Replies)
Discussion started by: fusion99
0 Replies
Login or Register to Ask a Question
NEWAPC(8)						      Network UPS Tools (NUT)							 NEWAPC(8)

NAME
newapc - Driver for American Power Conversion Smart Protocol UPS equipment NOTE
This man page only documents the hardware-specific features of the newapc driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
newapc should recognize all recent APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and Back-UPS Pro lines. Older APC models may work better with the apcsmart driver. The driver attempts to support every bell and whistle of the APC reporting interface, whether or not this is strictly sensible. Some older hardware may only report a handful of variables. This is usually not a bug - they just don't support anything else. CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable= definition described below. If your 940-0024C cable is broken or missing, use this diagram to build a clone: http://www.exploits.org/nut/library/cables/940-0024C.jpg EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): cable=940-0095B Configure the serial port for the APC 940-0095B dual-mode cable. sdtype=num Use shutdown type num, according to this table: 0: soft shutdown or powerdown, depending on battery status 1: soft shutdown followed by powerdown 2: instant power off 3: power off with grace period Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns. BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but some other unexpected values have occasionally slipped through. AUTHOR
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing heavily on the apcsmart driver by Russell Kroll). SEE ALSO
The core driver: nutupsdrv(8) The apcsmart driver: apcsmart(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ Tue Oct 22 2002 NEWAPC(8)