GSmartControl 0.8.1 (Default branch)


 
Thread Tools Search this Thread
Special Forums News, Links, Events and Announcements Software Releases - RSS News GSmartControl 0.8.1 (Default branch)
# 1  
Old 11-11-2008
GSmartControl 0.8.1 (Default branch)

Image GSmartControl is a graphical user interface for smartctl. It allows you to inspect the hard drive's SMART data to determine its health, as well as run various tests on it. License: GNU General Public License (GPL) Changes:
This release disables Linux "by-id" drive detection, as it's unreliable on some broken systems. It adds some more attribute descriptions. The project's names for attributes override smartctls' now. A proper "Add Device" dialog has been added for Windows. An icon and resource file have been added for Windows. Minor bugs have been fixed. Image

Image

More...
Login or Register to Ask a Question

Previous Thread | Next Thread
Login or Register to Ask a Question
OCF_PACEMAKER_HEALTH(7) 				      Pacemaker Configuration					   OCF_PACEMAKER_HEALTH(7)

NAME
ocf_pacemaker_HealthSMART - SMART health status SYNOPSIS
OCF_RESKEY_state=string OCF_RESKEY_drives=string OCF_RESKEY_devices=string OCF_RESKEY_temp_lower_limit=string OCF_RESKEY_temp_upper_limit=string OCF_RESKEY_temp_warning=string HealthSMART [start | stop | monitor | meta-data | validate-all] DESCRIPTION
Systhem health agent that checks the S.M.A.R.T. status of the given drives and updates the #health-smart attribute. SUPPORTED PARAMETERS
OCF_RESKEY_state = string [/HealthSMART-{OCF_RESOURCE_INSTANCE}.state] State file Location to store the resource state in. OCF_RESKEY_drives = string [/dev/sda] Drives to check The drive(s) to check as a SPACE separated list. Enter the full path to the device, e.g. "/dev/sda". OCF_RESKEY_devices = string Device types The device type(s) to assume for the drive(s) being tested as a SPACE separated list. OCF_RESKEY_temp_lower_limit = string [0] Lower limit for the red smart attribute Lower limit of the temperature in deg C of the drive(s). Below this limit the status will be red. OCF_RESKEY_temp_upper_limit = string [60] Upper limit for red smart attribute Upper limit of the temperature if deg C of the drives(s). If the drive reports a temperature higher than this value the status of #health-smart will be red. OCF_RESKEY_temp_warning = string [5] Deg C below/above the upper limits for yellow smart attribute Number of deg C below/above the upper/lower temp limits at which point the status of #health-smart will change to yellow. AUTHOR
Andrew Beekhof <andrew@beekhof.net> Author. Pacemaker Configuration 06/10/2014 OCF_PACEMAKER_HEALTH(7)