Opera 9.60 (Default branch)


 
Thread Tools Search this Thread
Special Forums News, Links, Events and Announcements Software Releases - RSS News Opera 9.60 (Default branch)
# 1  
Old 10-09-2008
Opera 9.60 (Default branch)

Opera is a full-featured Internet tool, most notably a fully standard conforming Web browser. Opera includes pop-up blocking, tabbed browsing, integrated searches, and advanced functions like a password manager, mouse gestures, native Scalable Vector Graphics (SVG) support, an email program, RSS newsfeeds, and IRC chat. It is designed to be fast and highly customizable. License: Free To Use But Restricted Changes:
Custom search engines and typed history can now also be synchronized with Opera Link. An optional Scroll Marker was implemented. RSS/Atom feeds can now be previewed before subscription. Follow/Ignore of threads and contacts was implemented. Low Bandwidth Mode for email was introduced. Many enhancements, improvements, bugfixes, and several security fixes were made. Image

Image

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

1 More Discussions You Might Find Interesting

1. Solaris

Opera 9.5 for Sparc

Has anyone gotten Opera 9.5 to work? I'm using Solaris Sparc 5.10. The browser is unusable. It crashes even when viewing Opera's Desktop Team blog. I've asked Opera about this, but no reply. I've never been able to get the 9.5 betas to work either. From one Opera user's blog, I don't see any... (0 Replies)
Discussion started by: cooldude
0 Replies
Login or Register to Ask a Question
emsweb(1M)																emsweb(1M)

NAME
emsweb - starts the HP-UX Event Monitoring Service tool (a Web interface) SYNOPSIS
[ ] [ ] DESCRIPTION
The HP-UX Event Monitoring Service tool ( ) is used to monitor resource instances and manages requests created on these instances. The HP-UX Event Monitoring Service tool provides both Web-based and terminal user interface. The Web-based interface is launched through the HP System Management Homepage. Superuser privileges are required to access the HP-UX Event Monitoring Service tool. A user who does not have superuser privileges has read-only access to the requests area in the HP-UX Event Monitoring Service tool and cannot modify requests. An attempt will be made to connect to a Mozilla/Netscape Web browser running on the X server defined by the DISPLAY environment variable. If a running Mozilla/Netscape client is found, it will be used, otherwise a new Mozilla/Netscape session will be initiated. This will only happen if the Mozilla/Netscape process is running in the same system as that referenced by the DISPLAY variable, unless the -F option is used. Note: By default, the HP-UX Event Monitoring Service tool (emsweb) invokes the Mozilla Web browser. If you want to support any other browser (Netscape), set the $BROWSER environment variable as shown below: The terminal user interface is invoked if any of the following conditions are true: o The command is invoked with the option. o The environment variable is not set. The Web-based interface is launched if all the following conditions are true: o The command is invoked with option. o The environment variable is set. o The command is available on the system. If the Web-based interface cannot be launched, invokes the terminal user interface. Options recognizes the following options: Forces a client browser to be used in less secure ways. The option forces the client browser to be used or started, even when the X-traffic between the X-server and the Mozilla browser is not secure. Use this option only when you are sure the network traffic between the host where Mozilla is running and the host in the DISPLAY variable is secure. If cannot start the Web browser, the terminal interface is started. When the HP-UX Event Monitoring Service Web interface is invoked by SAM, the option is used. If a privileged user (root) executes the command with the option, a temporary login bypass key is generated. The bypass key enables the user to access the Web interface without having to provide login information again. When the HP-UX Event Monitoring Service Web interface is invoked by SAM, the option is used. Opens the terminal interface for managing requests created to monitor resource instances regardless of the current setting of the environment variable. You can also start the HP-UX Event Monitoring Service tool using one of the following methods: o Invoke and select the Event Monitoring Service (character mode) functional area to launch the terminal user interface and the Event Monitoring Service (Web-based Interface) to launch the Web-based tool o Invoke the HP-UX Event Monitoring Service tool Web interface by typing the URL in the address bar of your browser, where hostname is the name of the server o Launch the HP-UX Systems Insight Manager on the server and select the Event Monitoring Service tool from the Configure -> HP-UX Configuration menu Online Help After the HP-UX Event Monitoring Service tool is started, the online help provides details on how to use the tool. RETURN VALUES
Upon completion, emsweb returns one of the following values: o 0 Successful o 1 An error occurred AUTHOR
was developed by Hewlett-Packard. SEE ALSO
emscli(1M), resls(1), resdata(1) emsweb(1M)