10 More Discussions You Might Find Interesting
1. Solaris
Hello. I'm a noob, but have managed to get to the point of Solaris storage server running 4 X 3Tb in a RAIDZ pool. My current system is sharing via SMB a few different ZFS devices (puddle/TV, puddle/Movies, puddle/Music, etc).
My main server is going to be OSX, Mountain Lion. What I have set... (4 Replies)
Discussion started by: BillyPrefect
4 Replies
2. AIX
Hi,
I have aix 6.1 box. I want to configure iscsi luns from netapp storage. I tried in google but not getting proper solution for that. i m not getting the proper iqn name.
Please share me the steps to complete this requirements.
Thanks in advance. (1 Reply)
Discussion started by: sunnybee
1 Replies
3. Red Hat
Hello Friends,
I am facing issue with the iSCSI configuration on some of our RHEL 5 servers,
When I restart the iSCSI service, it triggers the RHEL server reboot.
Could you please help me with this issue.
Below are the system details :
uname -a :
Linux za-rac-prd-01.abc.local... (2 Replies)
Discussion started by: Jeevanm
2 Replies
4. Linux
I am using Windows Server 2008R2 as a domain controller to 2 other servers and would like to use my Dell Powervault 770N as my NAS for data storage. I have FC that I would like to implement between the servers and the NAS (as an iSCSI target). I am brand new to this world; is this possible? I am... (2 Replies)
Discussion started by: NoviceAdmin
2 Replies
5. UNIX for Dummies Questions & Answers
Hi,
I want to set up a iscsi high availability with sheepdog distributed storage.
Here is my system set up. Four nodes with sheepdog distributed storage and i am sharing this storage through iscsi using two nodes as well as using a virtual ip set up using ucarp.Two nodes using same iqn. And... (0 Replies)
Discussion started by: jobycxa
0 Replies
6. AIX
I have an Equallogic SAN that I connect to from AIX (as well as Windows)
I had configured the connection and created the volumes and filesystems and all was working great.
Then one day, no communication between the SAN and the AIX (I can ping though) Anything I do on the AIX box at this time... (2 Replies)
Discussion started by: oldmanjoe
2 Replies
7. UNIX for Dummies Questions & Answers
how to change ethernet cable of iscsi initiator (iscsi client) (0 Replies)
Discussion started by: pankajd
0 Replies
8. Linux
Hi guys, I'd like to share experiences and knowledge about what should I use to install on a new storage server (with a lot of disks) in my network. What I want, is to move all domU's storage to this new storage server with AoE, iscsi or another thing. question:
1. Should I install openfiler or... (1 Reply)
Discussion started by: iga3725
1 Replies
9. AIX
Hi,
I have an iSCSI LUN of 200GB. I increased it to 250GB and when I try to increase the size of the vg, I'm getting an error that none of the volumes have increased in size.
How can I get the OS to see the additional 50GB?
---------- Post updated at 03:22 PM ---------- Previous update... (9 Replies)
Discussion started by: bbbngowc
9 Replies
10. AIX
I just reloaded an IBM P-Series with AIX 5.3 and would like to configure iscsi, can someone point me in the right direction to obtaining the initiator node name?
I ran lsattr -El iscsi0 - but the name that is displayed is not the correct name. I read somewhere the default node name is not... (2 Replies)
Discussion started by: bbbngowc
2 Replies
OCF_HEARTBEAT_ISCSI(7) OCF resource agents OCF_HEARTBEAT_ISCSI(7)
NAME
ocf_heartbeat_iscsi - Manages a local iSCSI initiator and its connections to iSCSI targets
SYNOPSIS
iscsi [start | stop | status | monitor | validate-all | methods | meta-data]
DESCRIPTION
OCF Resource Agent for iSCSI. Add (start) or remove (stop) iSCSI targets.
SUPPORTED PARAMETERS
portal
The iSCSI portal address in the form: {ip_address|hostname}[":"port] (required, string, no default)
target
The iSCSI target IQN. (required, string, no default)
discovery_type
Target discovery type. Check the open-iscsi documentation for supported discovery types. (optional, string, default sendtargets)
iscsiadm
open-iscsi administration utility binary. (optional, string, default iscsiadm)
udev
If the next resource depends on the udev creating a device then we wait until it is finished. On a normally loaded host this should be
done quickly, but you may be unlucky. If you are not using udev set this to "no", otherwise we will spin in a loop until a timeout
occurs. (optional, string, default yes)
SUPPORTED ACTIONS
This resource agent supports the following actions (operations):
start
Starts the resource. Suggested minimum timeout: 120.
stop
Stops the resource. Suggested minimum timeout: 120.
status
Performs a status check. Suggested minimum timeout: 30.
monitor
Performs a detailed status check. Suggested minimum timeout: 30. Suggested interval: 120.
validate-all
Performs a validation of the resource configuration. Suggested minimum timeout: 5.
methods
Suggested minimum timeout: 5.
meta-data
Retrieves resource agent metadata (internal use only). Suggested minimum timeout: 5.
EXAMPLE
The following is an example configuration for a iscsi resource using the crm(8) shell:
primitive example_iscsi ocf:heartbeat:iscsi
params
portal=string
target=string
op monitor depth="0" timeout="30" interval="120"
SEE ALSO
http://www.linux-ha.org/wiki/iscsi_(resource_agent)
AUTHOR
Linux-HA contributors (see the resource agent source for information about individual authors)
resource-agents 1.0.3 07/05/2010 OCF_HEARTBEAT_ISCSI(7)