Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

optiups(8) [sunos man page]

OPTIUPS(8)							    NUT Manual								OPTIUPS(8)

NAME
optiups - Driver for Opti-UPS (Viewsonic) UPS and Zinto D (ONLINE-USV) equipment NOTE
This man page only documents the hardware-specific features of the optiups driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
optiups was originally written against a PowerES 280es in nut-0.45. It was revised for nut-2.0.1 and tested against a PowerES 420E. It is expected to work with at least the PowerES, PowerPS, and PowerVS models. This driver additionally supports a Zinto D from ONLINE USV-Systeme AG because of their very similar commands, but it is unknown if it also works with other UPS from them. This driver will not work with the PowerES stock serial cable. You will need to construct your own three conductor cable: UPS 6 -> PC 3 UPS 9 -> PC 2 UPS 4 -> PC 5 The cable for Online-USV uses pin UPS 7 (not UPS 4) -> PC 5. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file: status_only Only poll for critical status information. Without this, optiups (and all NUT drivers) poll all sorts of information from the UPS fairly often. It is probably not often enough to hurt anything, so this option probably is not very useful, unless you have a flaky serial connection or a highly loaded machine. nowarn_noimp Does not print warnings when the UPS reports that a variable is not implemented or not pollable. Without the option you will get a message sent to your system logs each time NUT polls the UPS. If you specify nowarn_noimp, this message will only be logged once. fake_lowbatt This forces the low battery flag true. Without it, if you want to test your UPS, you will have to unplug it and wait until the battery drops to a low/critical voltage level before NUT will respond and power down your system. With the flag, NUT should power down the system soon after you pull the plug. When you are done testing, you should remove this flag. For basic shutdown configuration testing, the command upsmon -c fsd is preferred. powerup Zinto D from ONLINE-USV cannot be identified when switched to standby. Set this flag to allow the driver to power-up your Zinto UPS. This will also power-up your equipment connected to the UPS! BUGS
On the 420E, ups.serial and ups.temperature are unsupported features. This is not a bug in NUT or the NUT driver, just the way things are with this UPS. AUTHOR
Russell Kroll, Scott Heavner, Matthias Goebl SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 OPTIUPS(8)

Check Out this Related Man Page

MGE-ELLIPSE(8)						      Network UPS Tools (NUT)						    MGE-ELLIPSE(8)

NAME
mge-ellipse - Driver for MGE UPS serial SHUT Protocol UPS equipment NOTE
This man page only documents the hardware-specific features of the mge-ellipse driver. For information about the core driver, see nutups- drv(8). SUPPORTED HARDWARE
mge-ellipse should work with all recent MGE UPS models which use a serial protocol at 2400 bps, however I only tested it with a Ellipse 800S model so at the moment only the feature found is this (low end) model are supported. Older models (Pulsar series) use the U-Talk protocol and should use the mgeups driver. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): lowbatt=num Set the low battery warning threshold at which shutdown is initiated by upsmon(8). The factory default value is 30 (in percentage). offdelay=num Set the timer before the UPS is turned off after the kill power command is sent (via the -k switch). The factory default value is 120 (in seconds). ondelay=num Set the timer for the UPS to switch on in case the power returns after the kill power command had been sent but before the actual switch off. This ensures the machines connected to the UPS are, in all cases, rebooted after a power failure. The factory default value is 13 (in 10 seconds units). debug=1 logs quite a lot of debugging information to syslog. BUGS
The driver should be more generic to be able to handle the capabilities of the whole range of MGE UPS models using the SHUT protocol. AUTHOR
Philippe Marzouk <philm@users.sourceforge.net> SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ MGE UPS website for model and protocol information: http://www.mgeups.com Tue Oct 16 2002 MGE-ELLIPSE(8)
Man Page