PLIP(4) 			   BSD Kernel Interfaces Manual 			  PLIP(4)

NAME
     plip -- printer port Internet Protocol driver

SYNOPSIS
     plip* at ppbus?
     options PLIP_DEBUG

DESCRIPTION
     The plip driver allows a PC parallel printer port to be used as a point-to-point network
     interface between two similarly configured systems.  Data is transferred 4 bits at a time,
     using the printer status lines for input: hence there is no requirement for special bidirec-
     tional hardware and any standard AT-compatible printer port with working interrupts may be
     used.

     During the boot process, for each ppbus(4) device which is attached and has an interrupt
     capability, a corresponding plip device is attached.  The plip device is configured using
     ifconfig(8) using the options for a point-to-point network interface:

     ifconfig plip0 hostaddress destaddress [-link0|link0] [up|down] [...]

     Configuring a plip device ``up'' with ifconfig(8) causes the corresponding ppbus(4) to be
     reserved for PLIP until the network interface is configured ``down''.

     The communication protocol is selected by the link0 flag:

     -link0	 (default) Use FreeBSD mode (LPIP).  This is the simpler of the two modes and
		 therefore slightly more efficient.

     link0	 Use Crynwr/Linux compatible mode (CLPIP).  This mode has a simulated ethernet
		 packet header, and is easier to interface to other types of equipment.

     The interface MTU defaults to 1500, but may be set to any value.  Both ends of the link must
     be configured with the same MTU.  See ifconfig(8) for details on configuring network inter-
     faces.

   Cable Connections
     The cable connecting the two parallel ports should be wired as follows:

	     Pin     Pin     Description
	     2	     15      Data0 -> ERROR*
	     3	     13      Data1 -> SLCT
	     4	     12      Data2 -> PE
	     5	     10      Data3 -> ACK*
	     6	     11      Data4 -> BUSY
	     15      2	     ERROR* -> Data0
	     13      3	     SLCT   -> Data1
	     12      4	     PE     -> Data2
	     10      5	     ACK*   -> Data3
	     11      6	     BUSY   -> Data4
	     18-25   18-25   Ground

     Cables with this wiring are widely available as ``Laplink'' cables, and are often colored
     yellow.

     The connections are symmetric, and provide 5 lines in each direction (four data plus one
     handshake).  The two modes use the same wiring, but make a different choice of which line to
     use as handshake.

   FreeBSD LPIP mode
     The signal lines are used as follows:

     Data0 (Pin 2)    Data out, bit 0.

     Data1 (Pin 3)    Data out, bit 1.

     Data2 (Pin 4)    Data out, bit 2.

     Data3 (Pin 5)    Handshake out.

     Data4 (Pin 6)    Data out, bit 3.

     ERROR* (pin 15)  Data in, bit 0.

     SLCT (pin 13)    Data in, bit 1.

     PE (pin 12)      Data in, bit 2.

     BUSY (pin 11)    Data in, bit 3.

     ACK* (pin 10)    Handshake in.

     When idle, all data lines are at zero.  Each byte is signaled in four steps:  sender writes
     the 4 most significant bits and raises the handshake line; receiver reads the 4 bits and
     raises its handshake to acknowledge; sender places the 4 least significant bits on the data
     lines and lowers the handshake; receiver reads the data and lowers its handshake.

     The packet format has a two-byte header, comprising the fixed values 0x08, 0x00, immediately
     followed by the IP header and data.

     The start of a packet is indicated by simply signaling the first byte of the header.  The
     end of the packet is indicated by inverting the data lines (i.e. writing the ones-complement
     of the previous nibble to be transmitted) without changing the state of the handshake.

     Note that the end-of-packet marker assumes that the handshake signal and the data-out bits
     can be written in a single instruction - otherwise certain byte values in the packet data
     would falsely be interpreted as end-of-packet.  This is not a problem for the PC printer
     port, but requires care when implementing this protocol on other equipment.

   Crynwr/Linux CLPIP mode
     The signal lines are used as follows:

     Data0 (Pin 2)    Data out, bit 0.

     Data1 (Pin 3)    Data out, bit 1.

     Data2 (Pin 4)    Data out, bit 2.

     Data3 (Pin 5)    Data out, bit 3.

     Data4 (Pin 6)    Handshake out.

     ERROR* (pin 15)  Data in, bit 0.

     SLCT (pin 13)    Data in, bit 1.

     PE (pin 12)      Data in, bit 2.

     ACK* (pin 10)    Data in, bit 3.

     BUSY (pin 11)    Handshake in.

     When idle, all data lines are at zero.  Each byte is signaled in four steps:  sender writes
     the 4 least significant bits and raises the handshake line; receiver reads the 4 bits and
     raises its handshake to acknowledge; sender places the 4 most significant bits on the data
     lines and lowers the handshake; receiver reads the data and lowers its handshake.	[Note
     that this is the opposite nibble order to LPIP mode].

     Packet format is:

     Length (least significant byte)
     Length (most significant byte)
     12 bytes of supposed MAC addresses (ignored by FreeBSD).
     Fixed byte 0x08
     Fixed byte 0x00
     <IP datagram>
     Checksum byte.

     The length includes the 14 header bytes, but not the length bytes themselves nor the check-
     sum byte.

     The checksum is a simple arithmetic sum of all the bytes (again, including the header but
     not checksum or length bytes).  FreeBSD calculates outgoing checksums, but does not validate
     incoming ones.

     The start of packet has to be signaled specially, since the line chosen for handshake-in
     cannot be used to generate an interrupt.  The sender writes the value 0x08 to the data
     lines, and waits for the receiver to respond by writing 0x01 to its data lines.  The sender
     then starts signaling the first byte of the packet (the length byte).

     End of packet is deduced from the packet length and is not signaled specially (although the
     data lines are restored to the zero, idle state to avoid spuriously indicating the start of
     the next packet).

SEE ALSO
     atppc(4), ppbus(4), ifconfig(8)

HISTORY
     The plip driver was implemented for ppbus(4) in FreeBSD and imported into NetBSD.	Crynwr
     packet drivers implemented PLIP for MS-DOS.  Linux also has a PLIP driver.  The protocols
     are know as LPIP (FreeBSD) and CLPIP (Crynwr/Linux) in the documentation and code of this
     port.  LPIP originally appeared in FreeBSD.

AUTHORS
     This manual page is based on the FreeBSD lp manual page.  The information has been updated
     for the NetBSD port by Gary Thorpe.

BUGS
     Busy-waiting loops are used while handshaking bytes (and worse still when waiting for the
     receiving system to respond to an interrupt for the start of a packet).  Hence a fast system
     talking to a slow one will consume excessive amounts of CPU.  This is unavoidable in the
     case of CLPIP mode due to the choice of handshake lines; it could theoretically be improved
     in the case of LPIP mode.

     Regardless of the speed difference between hosts, PLIP is CPU-intensive and its made worse
     by having to send nibbles (4 bits) at a time.

     Polling timeouts are controlled by counting loop iterations rather than timers, and so are
     dependent on CPU speed.  This is somewhat stabilized by the need to perform (slow) ISA bus
     cycles to actually read the port.

     In the FreeBSD implementation, the idle state was not properly being restored on errors or
     when finishing transmitting/receiving.  This implementation attempts to fix this problem
     which would result in an unresponsive interface that could no longer be used (the port bits
     get stuck in a state and nothing can progress) by zeroing the data register when necessary.

     For unknown reasons, the more complex protocol (CLPIP) yields higher data transfer rates
     during testing so far.  This could possibly be because the other side can reliably detect
     when the host is transmitting in this implementation of CLPIP (this may not necessarily be
     true in Linux or MS-DOS packet drivers).  CLPIP gets about 70 KB/sec (the best expected is
     about 75 KB/sec) and LPIP get about 55 KB/sec.  This is despite LPIP being able to send more
     packets over the interface (tested with ``ping -f'') compared to CLPIP.