NAME
streampipes - force all pipes to be STREAMS-based VALUES
Failsafe Default Allowed values Recommended values DESCRIPTION
This tunable determines the type of pipe that is created by the system call. If set to the default value of zero, all pipes created by are normal HP-UX file-system pipes. If the value is non-zero, creates STREAMS-based pipes, and STREAMS modules can be pushed onto the result- ing stream. If this tunable is set to a non-zero value, the and module and driver must be configured in file Who Is Expected to Change This Tunable? Any customer. Restrictions on Changing Changes to this tunable take effect at next reboot. When Should the Tunable Be Turned On? If the customer uses applications that require STREAMS-based pipes, this tunable should be turned on. What Are the Side Effects of Turning the Tunable On? STREAMS-based pipes performance may differ from normal file system pipes. When Should the Tunable Be Turned Off? If the customer does not need the STREAMS-based pipes, this tunable should be turned off. What Are the Side Effects of Turning the Tunable Off? Applications that try to push STREAMS modules onto the pipe will fail. What Other Tunable Should Be Changed at the Same Time as This One? If this tunable is set to a non-zero value, the and module and driver must be configured in the file WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. Tunable Kernel Parameters streampipes(5)

Check Out this Related Man Page

STRCTLSZ(5)							File Formats Manual						       STRCTLSZ(5)

NAME
STRCTLSZ - maximum size of streams message control (bytes) VALUES
Failsafe Default Allowed values Recommended values DESCRIPTION
limits the maximum number of bytes of control data that can be inserted by in the control portion of any streams message on the system. If the tunable is set to zero, there is no limit on how many bytes can be placed in the control segment of the message. returns if the buffer being sent is larger than the current value of Who Is Expected to Change This Tunable? Any customer. Restrictions on Changing Changes to this tunable take effect at next reboot. When Should the Value of This Tunable Be Raised? The tunable should be increased by any customer if the customer's STREAMS module/driver(s) require more bytes in the control portion of any streams message than the current value. What Are the Side Effects of Raising the Value of This Tunable? The kernel will use more memory. During low memory situations, it may bring down system performance due to frequent swapping. When Should the Value of This Tunable Be Lowered? The tunable could be lowered by any customer if the customer's STREAMS module/driver(s) do not require a longer message size in the control portion than the current value. What Are the Side Effects of Lowering the Value of This Tunable? Possible improper functioning in any of the STREAMS module/driver(s). Possible performance degradation, particularly in networking. What Other Tunable Should Be Changed at the Same Time as This One? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. Tunable Kernel Parameters STRCTLSZ(5)