The command performs a number of checks to identify configuration problems in the Virtual Server Environment (VSE) Management Software.
The VSE Management Software runs under HP Systems Insight Manager (SIM). This command checks the software configuration on the HP SIM Cen-
tral Management Server (CMS), the communication between the CMS and managed systems, and the configuration of the software on managed sys-
tems. A summary of results is displayed, and detailed results are written to a log file, along with recommendations for resolving any
problems found.
You can execute vseassist from the HP SIM graphical user interface, from the command line on the CMS, or from the command line on a managed
system. HP recommends the following diagnostic procedure:
1. If you have root access to the CMS, execute the following command from the command line:
# -a
This will check the VSE Management Software configuration of the CMS, communication with all systems in the All VSE Resources
collection, and the VSE Management Software configuration on those systems. Refer to the summary output and examine the log file
for any problems. Follow the resolution steps in the log file to fix any problems that were found.
Fix problems in the CMS configuration first. You can verify that you have fixed those problems by executing the following com-
mand from the CMS command line:
# -c
You can also run this command directly from the HP SIM user interface. From the Diagnose menu, select Troubleshoot VSE Manage-
ment, then select Check VSE CMS Configuration.
2. After you have resolved all problems with the CMS configuration, check to see if there are any remaining communication issues
with the managed systems. From the CMS command line, specify the HP SIM nodenames or system collection names of your managed
systems using the following command:
# -l { -n nodename | -g collectionname ...}
Or, from the HP SIM user interface, select the managed systems, then from the Diagnose menu, select Troubleshoot VSE Management,
then select Check VSE CMS to Managed Node Communication.
3. After you have resolved the communication issues between the CMS and your managed systems, check the VSE Management Software con-
figuration on those systems. From the CMS command line, specify the HP SIM nodenames or system collection names of your managed
systems using the following command:
# -r { -n nodename | -g collectionname ...}
Or, from the HP SIM user interface, select the managed systems, then from the Diagnose menu, select Troubleshoot VSE Management,
then select Check VSE Managed Node Configuration.
4. If you are unable to resolve issues with one of your managed systems, you can install or copy vseassist to the managed system and
run it from the command line there. In the following command, replace cms with the short hostname or fully qualified domain name
of the CMS:
# -s -h cms
Options
If no options are specified, the command syntax is displayed and the command exits with return code 3.
The vseassist command recognizes the following options. For each option, a mnemonic is shown in parentheses to help you remember the
option letter.
-a (All) Perform all checks:
1. Check the VSE Management Software configuration of the CMS (as with the -c option).
2. Check the communication between the CMS and the specified managed systems (as with the -l option). If no managed sys-
tems are specified, then perform this check on all systems in the All VSE Resources collection.
3. Check the VSE Management Software configuration of the specified managed systems (as with the -r option). If no man-
aged systems are specified, then perform this check on all HP-UX and Microsoft(R) Windows(R) systems in the All VSE
Resources collection.
-c (CMS) Check the VSE Management Software configuration of the CMS.
-l (Link) From the CMS, check the communication between the CMS and the managed systems specified by the -n and -g options.
Some of the problems detected with this option include expired licenses, no open WBEM ports, and improperly configured SSH
authentication. These checks will verify if the CMS can communicate with the managed systems in order to perform VSE man-
agement functions.
This option requires one or more -n or -g options.
-r (Remote) From the CMS, check the VSE Management Software configuration of the HP-UX or Windows managed systems specified
by the -n and -g options. This option uses to copy the vseassist command to the managed systems, where it is executed
with the -s option.
In order for the -r option to succeed, the CMS must be able to communicate with the managed systems (as checked by the -l
option).
This option requires one or more -n or -g options.
Note: Remote operation is only possible for managed systems running HP-UX or Windows.
-n nodename
(Node) Specifies the name of a VSE managed system, using the node name by which the system is known to the CMS (as
reported by mxnode(1M)). Multiple -n and -g options can be used to specify multiple systems.
Note: This command is not designed to diagnose problems with non-VSE resources. Specifying non-VSE resources using -n or
-g options will not produce useful results.
-g collectionname
(Group) Specifies the name of a collection of systems known to the CMS. The specified checks will be performed for each
of the managed systems in the collection. Multiple -n and -g options can be used to specify multiple systems.
Note: System or collection names that include spaces must be enclosed in quotes.
Refer to mxquery(1M) for more information about collections under HP SIM.
-q (Quiet) No output will be generated on "stdout " or "stderr. The results will still be logged to the vseassist.log file.
-s (System) This option is used when running vseassist directly on managed systems. Some of the problems detected with this
option include missing WBEM providers, stalled WBEM process, and missing required patches.
When you use vseassist with the -r option on the CMS, will remotely execute vseassist on the managed systems using the -s
option.
-h cms (Host) Specifies the short hostname or fully qualified domain name of the CMS that is managing the system. This option is
passed to the remote execution of vseassist when you use the -r option on the CMS.
Installation
Beginning with VSE Management Software Version A.03.00.00, is installed on the CMS when the VSE Management Software is installed. For
information about updates, known issues, and workarounds, see the and the VSE Management website at http://docs.hp.com/en/vsemgmt/.
RETURN VALUES
0 The command completed successfully and no FAIL results were found.
1 The command completed successfully and one or more FAIL results were found.
2 Warnings, but no FAIL results were found.
3 Incorrect options were specified; the command syntax is displayed.
4 An unexpected internal error occurred. Contact your HP Support Representative, your HP Services Representative, or your
authorized HP reseller for assistance.
EXAMPLES
The specific checks performed may vary by operating system and system type of the CMS and managed systems. The following examples show the
kind of output that is produced, but the details may be different in your environment.
Check the configuration of a CMS named vsecms:
# vseassist -c
Version: A.04.01.00
+--------------------------------------------------------------+
| Performing CMS configuration verification |
+--------------------------------------------------------------+
vsecms:
HP SIM running........................................[PASS]
HP SIM memory configuration...........................[PASS]
VSE Management software running.......................[PASS]
Localhost name resolution.............................[PASS]
VSE manageable systems discovered in HP SIM...........[PASS]
Application Discovery server running..................[PASS]
File system free space................................[PASS]
Java JRE installed....................................[PASS]
Virtual Machine Management runnning...................[PASS]
VMM responsive........................................[PASS]
Virtual Connect Enterprise Manager responsive.........[N/A ]
Check Logical Server Automation installed.............[PASS]
Result Summary:
11 verification check(s) performed on 1 system(s)
11 check(s) passed
0 check(s) failed
0 check(s) warned
1 check(s) not applicable
See log for details:
C:Program FilesHPvselogsvseassist.log
Check the communication from the CMS to the managed systems named uxsys and winsys:
# vseassist -l -n uxsys -n winsys
Version: A.04.01.00
+--------------------------------------------------------------+
|Performing link verification of managed system(s) from the CMS|
+--------------------------------------------------------------+
uxsys.dom.com:
Managed system hostname resolution....................[PASS]
WBEM port open........................................[PASS]
WBEM authentication...................................[PASS]
SSH port open.........................................[PASS]
SSH authentication....................................[PASS]
SNMP server accessibility.............................[PASS]
Trial or permanent license applied....................[FAIL]
ISSUE: This system does not have a permanent license (LTU) or
all of the trial licenses have expired for the following
products:
- Virtual Machine Management
- Insight Power Manager
RESOLUTION: Purchase and apply a permanent LTU for the system
in order to manage it with the VSE Management
software. See the "VSE Management Software Getting
Started Guide" for information about installing and
configuring VSE licenses.
VMM agent compatibility...............................[N/A ]
winsys.dom.com:
Managed system hostname resolution....................[PASS]
WBEM port open........................................[PASS]
WBEM authentication...................................[FAIL]
ISSUE: Unable to either access WBEM credentials in HP SIM for
winsys.dom.com, or failed to use these credentials to
make a successful WBEM request to this system.
RESOLUTION: Make sure valid WBEM credentials have been entered
in HP SIM for this system, and that the WBEM server
is running on winsys.dom.com. Additional
information about the specific failure is available
in the vseassist log file.
SSH port open.........................................[PASS]
SSH authentication....................................[FAIL]
ISSUE: The winsys.dom.com node doesn't have the Operating
System information available in HP-SIM, which may
indicate a discovery problem in this node.
RESOLUTION: Verify if the WBEM credentials as well as the the
SSH credentials are properly configured for this node.
To configure the system credentials go to HP-SIM:
Options -> Protocol Settings -> System Protocol Settings
SNMP server accessibility.............................[PASS]
Trial or permanent license applied....................[PASS]
VMM agent compatibility...............................[PASS]
Result Summary:
15 verification check(s) performed on 2 system(s)
12 check(s) passed
3 check(s) failed
0 check(s) warned
1 check(s) not applicable
System Summary:
winsys.dom.com: 6 passed, 2 failed, 0 warned, 0 not applicable
uxsys.dom.com: 6 passed, 1 failed, 0 warned, 1 not applicable
See log for details: C:Program FilesHPvselogsvseassist.log
Check the configuration of the managed system named uxsys from the CMS:
# vseassist -r -n uxsys
Version: A.04.01.00
+--------------------------------------------------------------+
| Performing remote managed system(s) verification |
+--------------------------------------------------------------+
**** Start of output from remote execution of vseassist on
uxsys.dom.com ****
Running tool Execute Remote Vseassist Command with job id 1775.
Task Name :defRunNowTaskId_1202673463625_9
Job ID :1775
Tool Name :Execute Remote Vseassist Command
Job State :Complete
User Name :vsecmsAdministrator
Execute As User :root
Start Time :Sunday, February 10, 2008 12:57:43 PM MST
End Time :Sunday, February 10, 2008 12:58:20 PM MST
Elapsed Time :36 seconds 656 milliseconds
Node :uxsys.dom.com
Status :Complete
Exit Code :1
Files copied :2/2
Source :vsecms.dom.com:
C:Program FilesHPvseinvseassist
Destination :uxsys.dom.com:/var/adm/vseassist
Source :vsecms.dom.com:
C:Program FilesHPvselbin
un_va_and_cleanup
Destination :uxsys.dom.com:/var/adm/run_va_and_cleanup
STDOUT :
Version: A.04.01.00
Performing configuration verification of managed system
uxsys:
CMS hostname resolution...............................[FAIL]
ISSUE: The hostname of the CMS cannot be resolved from this
system.
RESOLUTION: Verify that your name resolution service is
configured properly.
WBEM running..........................................[PASS]
WBEM responsive.......................................[PASS]
System type matches HP SIM system type................[PASS]
Virtual machine WBEM provider validation..............[PASS]
nPartition WBEM provider validation...................[PASS]
Virtual partition WBEM provider validation............[N/A ]
Utilization Provider validation.......................[PASS]
Complex name valid....................................[PASS]
Virtual partition naming conflicts....................[N/A ]
nPartition name valid.................................[PASS]
LDAP/WBEM compatibility...............................[PASS]
Compare CMS and managed system nslookup...............[PASS]
SSH configuration validation..........................[PASS]
Application Discovery agent running...................[PASS]
Managed system required patches installed.............[PASS]
File system free space................................[PASS]
Java JRE bundle installed.............................[PASS]
Fair-Share Scheduler installed........................[PASS]
Processor Sets installed..............................[PASS]
gWLM agent configuration..............................[WARN]
WARNING: This system has the following gWLM agent issue(s):
- The gWLM agent bundle is installed but the gWLM agent
LTU bundle is not installed. This is required to use
gWLM when the trial license expires.
RESOLUTION: Take the following steps to correct these issue(s):
- Install the gWLM agent LTU ('T2762A' bundle) if you
plan to manage this system with gWLM. The latest
installation instructions ("VSE Management Software
Installation and Update Guide") can be found at
http://docs.hp.com/en/vse.html.
iCap status...........................................[N/A ]
Result Summary:
19 verification check(s) performed on 2 system(s)
17 check(s) passed
1 check(s) failed
1 check(s) warned
3 check(s) not applicable
System Summary:
: 0 passed, 0 failed, 0 warned, 1 not applicable
uxsys: 17 passed, 1 failed, 1 warned, 2 not applicable
See log for details: /var/adm/syslog/vseassist.log
**** End of output from remote execution of vseassist on
uxsys.dom.com ****
See log for details: C:Program FilesHPvselogsvseassist.log
AUTHORS
vseassist was developed by Hewlett-Packard Company.
RELEASE VERSION
VSE Management Software Version 4.1
FILES
Detailed results of the checks performed by vseassist are written to the log file. Examine the log file for recommended steps to resolve
any problems found. Note: The log file is not automatically pruned.
HP-UX: /var/adm/syslog/vseassist.log
Windows: install-pathlogsvseassist.log
SEE ALSO
VSE Management Software online help
VSE Management manuals from http://docs.hp.com/en/vse.html:
, .
Related manpages:
capcollect(1M), mxexec(1M), mxnode(1M), mxquery(1M), vseinitconfig(1M), vselicense(1M)
vseassist(1M)