xpachanges(7) SAORD Documentation xpachanges(7)NAME
XPAChanges - Changes For Users from XPA 1.0 and 2.0
SYNOPSIS
This document describes changes that will affect users who migrate from XPA 1.0 to XPA 2.0.
DESCRIPTION
There have been a few changes that affect users who upgrade XPA from version 1.0 to version 2.0. These changes are detailed below.
o XPA commands no longer have a resolver routine (this is open to negotiations, but we decided the idea was dumb). For the SAOtng pro-
gram, this means that you must explicitly specify the access point, i.e.,:
cat foo.fits | xpaset SAOtng fits
instead of:
cat foo.fits | xpaset SAOtng
o By default, xpaset, xpaget, etc. now wait for the server callback to complete; i.e., the old -W is implied (and the switch is
ignored). This allows support for better error handling. If you want xpaset, etc. to return before the callback is complete, use -n
switch:
echo "file foo.fits" | xpaset -n SAOtng
o The old -w switch in xpaset and xpaget is no longer necessary (and is ignored), since you can have more than one process communicating
with an xpa access point at one time.
o The new -p switch on xpaset means you need not read from stdout:
xpaset -p SAOtng colormap I8
will send the paramlist to the SAOtng callback without reading from stdin.
SEE ALSO
See xpa(7) for a list of XPA help pages
version 2.1.14 June 7, 2012 xpachanges(7)
Check Out this Related Man Page
xpamb(1) SAORD Documentation xpamb(1)NAME
xpamb - the XPA Message Bus
SYNOPSIS
The xpamb program can act as a "classical" message bus interface between clients and servers. A client can send a data request to the mes-
sage bus, which then interfaces with multiple servers and returns the data back to the client.
OPTIONS
For xpaset, several optional switches are used to save data and manipulate the stored data:
o -data [name]
Add the supplied data buffer to a pool of stored data buffers, using the specified name as a unique identifier for later retrieval. An
error occurs if the name already exists (use either replace or del to rectify this). The -add switch is supported for backwards com-
patibility with xpa 2.0.
o -replace [name]
Replace previously existing stored data having the same unique name with new data. This essentially is a combination of the del and
data commands.
o -info ["'info string'"]
When adding a data buffer, you can specify an informational string to be stored with that data. This string will be returned by
xpaget:
xpaget xpamb foo -info
(along with other information such as the date/time of storage and the size of the data buffer) if the -info switch is specified. If
the info string contains spaces, you must enclose it in two sets of quotes:
cat foo | xpaset xpamb -store foo -info "'this is info on foo'"
The first set of quotes is removed by the shell while the second is used to delineate the info string.
o -send [name]
Broadcast the stored data buffer to the named template.
o -del [name]
Delete the named data buffer and free all allocated space.
Switches can be used in any combination that makes sense. For example:
cat foo.fits | xpaset xpamb -store foo -info "FITS" "DS9:*" fits foo.fits
will broadcast the foo.fits image to all access points of class DS9. In addition, the foo.fits file will be stored under the name of foo
for later manipulation such as:
xpaset -p xpamb -send foo "DS9:*" fits foo.fits
will re-broadcast the foo.fits image to all access points of class "DS9".
DESCRIPTION
A "classical" message bus (such as ToolTalk) consists of servers and clients, along with a mediating program that transfers data between
different processes. XPA takes a slightly different approach in that communication between clients and servers is direct. This generally
is the correct technique when there is only one connection (or even a small number of connections), but can become inefficient for the
serving program if a large amount of data is being transferred to many clients. For example, if a real-time data acquisition program is
broadcasting a FITS image to several clients, it would need to transmit that image to each client individually. This might interfere with
its own processing cycles. The preferable mechanism would be to pass the image off to an intermediate program that can then broadcast the
data to the several clients.
The xpamb program can alleviate such problems by functioning as a message bus in cases where such an intermediary process is wanted. It
pre-defines a single access point named XPAMB - xpamb to which data can be sent for re-broadcast. You also can tell xpamb to save the
data, and associate with that data a new access point, so that it can be retrieved later on.
All interaction with xpamb is performed through xpaset and xpaget (or the corresponding API routines, XPASet() and XPAGet()) to the XPAMB -
xpamb access point. That is, xpamb is just another XPA-enabled program that responds to requests from clients. The paramlist is used to
specify the targets to which the data will be for re-broadcast, as well as the re-broadcast paramlist:
data | xpaset xpamb [switches] broadcast-target broadcast-paramlist
Optional switches are used to store data, and manipulate stored data, and are described below.
In its simplest form, you can, for example, send a FITS image to xpamb for broadcasting to all ds9 image simply by executing:
cat foo.fits | xpaset xpamb "DS9:*" fits foo.fits
Since DS9 is the class name for the ds9 image display program, this will result in the FITS image being re-sent to all fits access points
for all active image display programs.
You can send stored data and new data to the same set of access points at the same time. The stored data always is send first, followed by
the new data:
cat foo2.fits | xpaset xpamb -send foo "DS9:*" fits foo.fits
will first send the foo.fits file, and then the foo2.fits file to all access points of class DS9. Notice that in this example, the
foo2.fits file is not stored, but it could be stored by using the -store [name] switch on the command line.
The xpaget command can be used to retrieve a data from XPA access points or from a stored data buffer, or retrieve information about a
stored data buffer. If no arguments are given:
xpaget xpamb
then information about all currently stored data buffers is returned. This information includes the data and time at which the data was
stored, the size in bytes of the data, and the supplied info string.
If arguments are specified, they will be in the form:
xpaget xpamb [-info] [-data] [name [paramlist]]
If the optional -info and/or -data switches are specified, then information and/or data will be returned for the named data buffer fol-
lowing the switches. You can use either or both of these switches in a single command. For example, if the -info switch is used:
xpaget xpamb -info foo
then the info about that stored data buffer will be returned. If the -data is used with a specific name:
xpaget xpamb -data foo
then the stored data itself will be returned. If both are used:
xpaget xpamb -info -data foo
then the info will be returned, followed by the data. Note that it is an error to specify one of these switches without a data buffer name
and that the paramlist will be ignored.
If neither the -info or -data switch is specified, then the name refers to an XPA access point (with an optional paramlist following).
For example:
xpaget xpamb ds9 file
is equivalent to:
xpaget ds9 file
SEE ALSO
See xpa(7) for a list of XPA help pages
version 2.1.14 June 7, 2012 xpamb(1)