Nagios plugin 1-wire temperature 1.0 (Default branch)

 
Thread Tools Search this Thread
Special Forums UNIX and Linux Applications Infrastructure Monitoring Nagios plugin 1-wire temperature 1.0 (Default branch)
# 1  
Old 02-25-2009
Nagios plugin 1-wire temperature 1.0 (Default branch)

Nagios plugin 1-wire temperature uses a 1-wire sensor to measure temperature and returns WARNING or CRITICAL if it is too low or high. License: GNU General Public License v2 Changes:
First and inititial version Image

Image

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

4 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Check_by_ssh plugin (nagios users)

Hi Everyone, I need help from the nagios users out there. I have setup a new service using the check_by_ssh plugin and is executing the script on the remote server but I wonder what am I missing because is not picking up the returning values of my script. Basically the script on the remote host... (1 Reply)
Discussion started by: arizah
1 Replies

2. Linux

Nagios Plugin [.sh] not working

Hello. I am working on setup a nagios plugin for monitor tomcat instance from tomcat manager. This is a script file downloaded from http://exchange.nagios.org/directory/Plugins/Java-Applications-and-Servers/Apache-Tomcat/check_TomcatApplication/details This is working fine when executed as... (3 Replies)
Discussion started by: sunnysthakur
3 Replies

3. Infrastructure Monitoring

Nagios plugin check_local_mrtgtraf

Hi, Can somebody direct me to these plugin for nagios check_local_mrtgtraf check_snmp Documentation says it's a part of the latest plugin release but i have installed it and it seems it is not. I do have done search but couldn't find any link from where i can download these. Thanks in... (1 Reply)
Discussion started by: uxadmin007
1 Replies

4. Solaris

Nagios NRPE plugin won't install

Hi have a Solaris 9 box and I'm trying to install Nagios on it. I've installed the GCC compiler as well as OpenSSL and OpenSSH. When I run the # ./configure for the nrpe plugin it executes without any obvious errors. However, when I run the # make install afterwards if fails with the... (0 Replies)
Discussion started by: soliberus
0 Replies
Login or Register to Ask a Question
DIGITEMP(1)						      General Commands Manual						       DIGITEMP(1)

NAME
digitemp - program to read from temperature sensors. SYNOPSIS
digitemp [options] DESCRIPTION
DigiTemp uses the Dallas 1-wire bus to read temperatures from digital sensors attached to a serial port adapter. It handles initializing the bus, searching for attached devices, reading devices and custom log strings. It suports the following temperature devices: DS1820, DS18S20, DS18B20, DS1822 It also handles the DS2406 1-wire hub switches, and DS2422 and DS2423 counters. DigiTemp uses either the DS9097 passive serial port adapter, or the DS2480B based DS9097U adapter (recommended). OPTIONS
At least 1 action must be given, along with some optional arguments. Actions are one (and only on) of the -w -t -a -w options -h, -? Show summary of options. -v Show verbose output. -i Initialize .digitemprc file, search the bus for all supported devices. -w Walk the full device tree and display the serial number and type of all devices detected on the bus. -s /dev/ttyS0 Set serial port to use. Make sure you have permission to access this port. -l /var/log/temperature Send output to logfile, the output format is defined by the .B -o command -c digitemp.conf Set digitemp configuration file. The default is .digitemprc in the current directory. -r 1000 Read delay in ms. This sets the amount of time to wait between sending the temperature conversion command and reading the result. The DS18S20 takes about 750mS to do the temperature conversion. Default is 1000mS (1 sec). -t # Read sensor number #, the # depends on the order of the sensors in the .digitemprc file. -q Quiet output, no copyright banner. -a Read all sensors. -A Treat DS2438 as A/D converter, output raw voltages -d 5 Delay between samples (in seconds). -n 50 Number of times to repeat the command. -O"counter format string" See Counter Format below. -o [1..3] ["output format string"] See Temperature Format below. -H"Humidity format string" See Humidity Format below. Temperature Format The temperature format can be either a numeric value, or a string. The numeric values select pre-configured output formats: 1 = One line per sensor, time, C, F (default) 2 = One line per sample, elapsed time, temperature in C 3 = Same as #2, except temperature is in F #2 and #3 have the data separated by tabs, suitable for import into a spreadsheet or other graphing software. The format string uses strftime tokens plus 5 special ones for DigiTemp: %s for sensor # %C for centigrade %F for fahrenheit %R to output the hex serial number %N for seconds since Epoch. The case of the token is important! The default format string is: "%b %d %H:%M:%S Sensor %s C: %.2C F: %.2F" which gives you an output of: May 24 21:25:43 Sensor 0 C: 23.66 F: 74.59 The DS2438 sensor can be used for a variety of things. It includes a temperature sensor and A/D converter. DigiTemp defaults to using it as a humidity sensor. The raw voltages can be displayed by passing the -A argument When the -o2 or -o3 log options are used the attached DS2438's temperatures will be output without the humidity. Counter Format String The counter format string is similar, adding these tokens: %n is the counter #, which depends on its position in the .digitemprc file %C is the count in decimal. Humidity Format String The Humidity format string is the same as the temperature format string with the addition of this format specifier: %h is the humidity in 0-100% AUTHOR
This manual page was written by Jesus Roncero <jesus@roncero.org>, for the Debian project (but may be used by others). Modifications by Brian C. Lane <bcl@brianlane.com> UPDATES
DigiTemp updates can be found on the http://www.digitemp.com website. June 2005 DIGITEMP(1)