HP-UX 11i Security Containment

Has there been much success (or failure for that matter) around implementing these three core techbologies? Has it delievered what it has promised (fine grain privileges, compartments, and role based access control)?

I haven't found very much commentary here or around the Internet on the subject.
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. HP-UX

Eclipse 3.1 on HP-UX 11i

Hey guys how do you run eclipse on HP-UX 11i? there's a startup.jar and an eclipse file ( which is not an executable ) I get different errors try to run the jar file with different java versions. I have all the possible java vm's installed. (0 Replies)
Discussion started by: binary0x01
0 Replies

2. HP-UX

Where can i get hp-ux 11i v3

I have to access to hp integrity bl870c server blade and i have no hp-ux 11i v2 or 11i v3 DVD's where can i get a DVD or download it . as i have no direct contact with vendor . thanks (4 Replies)
Discussion started by: h@foorsa.biz
4 Replies

3. HP-UX

Installing HP 11i v3

Hi, I want to install HP 11i v3 OS on PA-RISC systems, which already have HP11i v1 operating system. I want to know that what are software and hardware requirements I will need for doing this? Thanks in Advance Mike (1 Reply)
Discussion started by: Mike1234
1 Replies

4. HP-UX

HP UX 11i and HP C8000

Hey, i want install HP UX 11i on HP C8000. When i start the C8000 i get a prompt. On this Prompt i write BOot P1 P1 is my DVD-ROM (IDE). I get the Message "ERROR: Not a boot path". When i write SEArch the Prompt said: P0 scsiA.6 HP73.4MAT3073NP P1 ide.1 ... (2 Replies)
Discussion started by: numx
2 Replies

5. HP-UX

About compatibility of HP-UX 11i

Could you please tell me if Informix 7.20 UD2 works on HP-UX 11i and if applications that works on HP-UX 10.20 and Informix 7.20 UD2 works on HP-UX 11i. Thanks a lot. (0 Replies)
Discussion started by: Irene Martínez
0 Replies

6. HP-UX

How to use CSTM on HP-Ux 11i V2

Hi, Newbie here......I am an new guy on HP-Ux... may i ask all the the guru's and who has eperienced here to enlightened me on how to use the CSTM command. My goal is to view the current HW installed on the Server. Thanks in advance. (1 Reply)
Discussion started by: renobal
1 Replies

7. HP-UX

HP 11i 64

Hi, could somebody confirm that HP 11i 64 is a 64 bits system ? Thank you (1 Reply)
Discussion started by: aribault
1 Replies

8. HP-UX

HP-UX 11i v2 for PA-RISC

Hello, i trying to get HP-UX 11i v2 for PA-RISC. I`im to poor to buy this system, so I`am asking that someone can help me. best regards email removed (1 Reply)
Discussion started by: mruczas
1 Replies

9. HP-UX

HP-UX 11i

Need to find the changes made in hp-ux11iv2 and how to migrate from hp-ux11i to hp-ux11iv2. Thanks in advance. (1 Reply)
Discussion started by: mhbd
1 Replies

10. UNIX for Dummies Questions & Answers

hp-ux 11i

Need to find the changes made in hp-ux11iv2 and how to migrate from hp-ux11i to hp-ux11iv2. Thanks in advance. (1 Reply)
Discussion started by: mhbd
1 Replies
Login or Register to Ask a Question
nice(2) 							System Calls Manual							   nice(2)

NAME
nice - change priority of a process SYNOPSIS
DESCRIPTION
adds the value of priority_change to the nice value of the calling process. A process's is a positive number for which a more positive value results in lower CPU priority. A maximum nice value of 39 and a minimum nice value of 0 are imposed by the system. Requests for values above or below these limits result in the nice value being set to the corresponding limit. If the calling process contains more than one thread or lightweight process (i.e., the process is multi-threaded) this function shall apply to all threads or lightweight processes in the calling process. Security Restrictions Some or all of the actions associated with this system call are subject to compartmental restrictions. See compartments(5) for more infor- mation about compartmentalization on systems that support that feature. Compartmental restrictions can be overridden if the process pos- sesses the privilege (COMMALLOWED). Processes owned by the superuser may not have this privilege. Processes owned by any user may have this privilege, depending on system configuration. Some or all of the actions associated with this system call require the (OWNER) and/or the (LIMIT) privileges. Processes owned by the superuser will have these privileges. Processes owned by other users may have privilege(s), depending on system configuration. See privi- leges(5) for more information about privileged access on systems that support fine-grained privileges. RETURN VALUE
Upon successful completion, returns the new nice value minus 20. Otherwise, a value of -1 is returned and is set to indicate the error. Note that assumes a user process priority value of 20. If a user having appropriate privileges has changed the user process priority value to something less than 20, certain values for priority_change can cause to return -1, which is indistinguishable from an error return. ERRORS
[EPERM] fails and does not change the nice value if priority_change is negative or greater than 40, and the effective user ID of the calling process is not a user having appropriate privileges. SEE ALSO
nice(1), renice(1M), exec(2), privileges(5). STANDARDS CONFORMANCE
nice(2)