need your help for HP virtual array 7400 disk replacement error


 
Thread Tools Search this Thread
Operating Systems HP-UX need your help for HP virtual array 7400 disk replacement error
# 1  
Old 11-17-2009
need your help for HP virtual array 7400 disk replacement error

hi all!
I found a the state of disk at JA0/D13 was failed this morning.
then i replaced it this afternoon,but i run
#dsp -s

the array status displayed

====================================
STATUS
Subsystem State: 1
The Subsystem is TESTING.
The array is REBUILDING and is 87% complete.
WARNINGS
Missing Drive
=====================================
i checked the missing drive is failed one,but the new one in the status showed"included and good"

how can i do next?thank you all reply to me!thank you!


Joy

---------- Post updated at 08:47 PM ---------- Previous update was at 08:43 PM ----------

should I force include new disk to the subsystem?how to do?

thankyou!

---------- Post updated 11-17-09 at 02:10 PM ---------- Previous update was 11-16-09 at 08:47 PM ----------

hi all!The error has corrected automatically.
I think the array was ejecting failed disk while rebuilding,but not full completed.
I replaced the disk in the rebuilding procedure,then array needed to rebuild again to eject failed disk id from records of subsystem,then the array add new disk id to the records of subsystem and do rebuild.

thank you all for viewing the thread!thank you unix.com!
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

2. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

3. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

4. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

5. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

6. Linux

C++ Code to Access Linux Hard Disk Sectors (with a LoopBack Virtual Hard Disk)

Hi all, I'm kind of new to programming in Linux & c/c++. I'm currently writing a FileManager using Ubuntu Linux(10.10) for Learning Purposes. I've got started on this project by creating a loopback device to be used as my virtual hard disk. After creating the loop back hard disk and mounting it... (23 Replies)
Discussion started by: shen747
23 Replies

7. Shell Programming and Scripting

Perl Array Elements Replacement

Hello, I have the following perl array: @longname = (Fasthernet0/0 Fasthernet0/1 Serial0/1/0 Serial0/2/1 Tunnel55 Tunnel77) with the followinh array: @shortname = (Fa0/0 Fa0/1 Se0/1/0 Se0/2/1 Tu55 Tu77) in other words, I need to remove the following from each element in the array... (4 Replies)
Discussion started by: ahmed_zaher
4 Replies

8. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

9. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

10. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies
Login or Register to Ask a Question
vxsparecheck(1M)														  vxsparecheck(1M)

NAME
vxsparecheck - monitor Veritas Volume Manager for failure events and replace failed disks SYNOPSIS
/etc/vx/bin/vxsparecheck [mail-address...] DESCRIPTION
The vxsparecheck command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, waiting for failures to occur. It then sends mail via mailx to the logins specified on the command line, or (by default) to root. It then replaces any failed disks. After an attempt at replacement is complete, mail will be sent indicating the status of each disk replacement. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed subdisks: subdiskname ... failed volumes: volumename ... The Volume Manager will attempt to find hot-spare disks to replace any failed disks and attempt to reconstruct any data in volumes that have storage on the failed disk. The medianame list specifies disks that appear to have completely failed. The plexname list show plexes of mirrored volumes that have been detached due to I/O failures experienced while attempting to do I/O to subdisks they contain. The subdiskname list specifies subdisks in RAID-5 volumes that have been detached due to I/O errors. The volumename list shows non-RAID-5 volumes that have become unusable because disks in all of their plexes have failed (and are listed in the ``failed disks'' list) and shows those RAID-5 volumes that have become unusable because of multiple failures. If any volumes appear to have failed, the following paragraph will be included in the mail: The data in the failed volumes listed above is no longer available. It will need to be restored from backup. Replacement Procedure After mail has been sent, vxsparecheck finds a hot spare replacement for any disks that appear to have failed (that is, those listed in the medianame list). This involves finding an appropriate replacement for those eligible hot spares in the same disk group as the failed disk. A disk is eligible as a replacement if it is a valid Veritas Volume Manager disk (VM disk), has been marked as a hot-spare disk and con- tains enough space to hold the data contained in all the subdisks on the failed disk. To determine which disk from among the eligible hot spares to use, vxsparecheck first checks the file /etc/vx/sparelist (see Sparelist File below). If this file does not exist or lists no eligible hot spares for the failed disk, the disk that is ``closest'' to the failed disk is chosen. The value of ``closeness'' depends on the controller, target and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; and a disk under the same target as the failed disk is closer than one under a different target. If no hot spare disk can be found, the following mail is sent: No hot spare could be found for disk medianame in diskgroup. No replacement has been made and the disk is still unusable. The mail then explains the disposition of volumes that had storage on the failed disk. The following message lists disks that had storage on the failed disk, but are still usable: The following volumes have storage on medianame: volumename These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the failure of the disk, the following message is included: The following volumes: volumename have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included The following RAID-5 volumes: volumename had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. If a hot-spare disk was found, a hot-spare replacement is attempted. This involves associating the device marked as a hot spare with the media record that was associated with the failed disk. If this is successful, the vxrecover(1M) command is used in the background to recover the contents of any data in volumes that had storage on the disk. If the hot-spare replacement fails, the following message is sent: Replacement of disk medianame in group diskgroup failed. The error is: error message If any volumes (RAID-5 or otherwise) are rendered unusable due to the failure, the following message is included: The following volumes: volumename occupy space on the failed disk and have no other available mirrors or have experienced other failures. These volumes are unusable, and the data they contain is unavailable. If the hot-spare replacement procedure completed successfully and recovery is under way, a final mail message is sent: Replacement of disk medianame in group diskgroup with disk device sparedevice has successfully completed and recovery is under way. If any non-RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following volumes: volumename occupy spare on the replaced disk, but have no other enabled mirrors on other disks from which to perform recovery. These volumes must have their data restored. If any RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following RAID-5 volumes: volumename have subdisks on the replaced disk and have experienced other failures that prevent recovery. These RAID-5 volumes must have their data restored. If any volumes (RAID-5 or otherwise) were rendered unusable, the following message is also included: To restore the contents of any volumes listed above, the volume should be started with the command: vxvol -f start volumename and the data restored from backup. Sparelist File The sparelist file is a text file that specifies an ordered list of disks to be used as hot spares when a specific disk fails. The system- wide sparelist file is located in /etc/vx/sparelist. Each line in the sparelist file specifies a list of spares for one disk. Lines beginning with the pound (#) character and empty lines are ignored. The format for a line in the sparelist file is: [ diskgroup:] diskname : spare1 [ spare2 ... ] The diskgroup field, if present, specifies the disk group within which the disk and designated spares reside. If this field is not speci- fied, the default disk group is determined using the rules given in the vxdg(1M) manual page. The diskname specifies the disk for which spares are being designated. The spare list after the colon lists the disks to be used as hot spares. The list is order dependent; in case of failure of diskname, the spares are tried in order. A spare will be used only if it is a valid hot spare (see above). If the list is exhausted without finding any spares, the default policy of using the closest disk is used. FILES
/etc/vx/sparelist Specifies a list of disks to serve as hot spares for a disk. NOTES
The sparelist file is not checked in any way for correctness until a disk failure occurs. It is possible to inadvertently specify a non- existent disk or inappropriate disk or disk group. Malformed lines are also ignored. SEE ALSO
mailx(1), vxintro(1M), vxnotify(1M), vxrecover(1M), vxrelocd(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxsparecheck(1M)