need your help for HP virtual array 7400 disk replacement error


 
Thread Tools Search this Thread
Operating Systems HP-UX need your help for HP virtual array 7400 disk replacement error
# 1  
Old 11-17-2009
need your help for HP virtual array 7400 disk replacement error

hi all!
I found a the state of disk at JA0/D13 was failed this morning.
then i replaced it this afternoon,but i run
#dsp -s

the array status displayed

====================================
STATUS
Subsystem State: 1
The Subsystem is TESTING.
The array is REBUILDING and is 87% complete.
WARNINGS
Missing Drive
=====================================
i checked the missing drive is failed one,but the new one in the status showed"included and good"

how can i do next?thank you all reply to me!thank you!


Joy

---------- Post updated at 08:47 PM ---------- Previous update was at 08:43 PM ----------

should I force include new disk to the subsystem?how to do?

thankyou!

---------- Post updated 11-17-09 at 02:10 PM ---------- Previous update was 11-16-09 at 08:47 PM ----------

hi all!The error has corrected automatically.
I think the array was ejecting failed disk while rebuilding,but not full completed.
I replaced the disk in the rebuilding procedure,then array needed to rebuild again to eject failed disk id from records of subsystem,then the array add new disk id to the records of subsystem and do rebuild.

thank you all for viewing the thread!thank you unix.com!
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

2. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

3. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

4. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

5. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

6. Linux

C++ Code to Access Linux Hard Disk Sectors (with a LoopBack Virtual Hard Disk)

Hi all, I'm kind of new to programming in Linux & c/c++. I'm currently writing a FileManager using Ubuntu Linux(10.10) for Learning Purposes. I've got started on this project by creating a loopback device to be used as my virtual hard disk. After creating the loop back hard disk and mounting it... (23 Replies)
Discussion started by: shen747
23 Replies

7. Shell Programming and Scripting

Perl Array Elements Replacement

Hello, I have the following perl array: @longname = (Fasthernet0/0 Fasthernet0/1 Serial0/1/0 Serial0/2/1 Tunnel55 Tunnel77) with the followinh array: @shortname = (Fa0/0 Fa0/1 Se0/1/0 Se0/2/1 Tu55 Tu77) in other words, I need to remove the following from each element in the array... (4 Replies)
Discussion started by: ahmed_zaher
4 Replies

8. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

9. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

10. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies
Login or Register to Ask a Question
metareplace(1M) 					  System Administration Commands					   metareplace(1M)

NAME
metareplace - enable or replace components of submirrors or RAID5 metadevices SYNOPSIS
/usr/sbin/metareplace -h /usr/sbin/metareplace [-s setname] -e mirror component /usr/sbin/metareplace [-s setname] mirror component-old component-new /usr/sbin/metareplace [-s setname] -e RAID component /usr/sbin/metareplace [-s setname] [-f] RAID component-old component-new DESCRIPTION
The metareplace command is used to enable or replace components (slices) within a submirror or a RAID5 metadevice. When you replace a component, the metareplace command automatically starts resyncing the new component with the rest of the metadevice. When the resync completes, the replaced component becomes readable and writable. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replacements. Note that the new component must be large enough to replace the old component. A component may be in one of several states. The Last Erred and the Maintenance states require action. Always replace components in the Maintenance state first, followed by a resync and validation of data. After components requiring maintenance are fixed, validated, and resynced, components in the Last Erred state should be replaced. To avoid data loss, it is always best to back up all data before replacing Last Erred devices. OPTIONS
Root privileges are required for all of the following options except -h. -e Transitions the state of component to the available state and resyncs the failed component. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replace- ments. This command is useful when a component fails due to human error (for example, accidentally turning off a disk), or because the component was physically replaced. In this case, the replacement component must be partitioned to match the disk being replaced before running the metareplace command. -f Forces the replacement of an errored component of a metadevice in which multiple components are in error. The component determined by the metastat display to be in the ``Maintenance'' state must be replaced first. This option may cause data to be fabricated since multiple components are in error. -h Display help message. -s setname Specifies the name of the diskset on which metareplace will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices. mirror The metadevice name of the mirror. component The logical name for the physical slice (partition) on a disk drive, such as /dev/dsk/c0t0d0s2. component-old The physical slice that is being replaced. component-new The physical slice that is replacing component-old. RAID The metadevice name of the RAID5 device. EXAMPLES
Example 1: Recovering from Error Condition in RAID5 Metadevice This example shows how to recover when a single component in a RAID5 metadevice is errored. # metareplace d10 c3t0d0s2 c5t0d0s2 In this example, a RAID5 metadevice d10 has an errored component, c3t0d0s2, replaced by a new component, c5t0d0s2. Example 2: Use of -e After Physical Disk Replacement This example shows the use of the -e option after a physical disk in a submirror (a submirror of mirror d11, in this case) has been replaced. # metareplace -e d11 c1t4d0s2 Note: The replacement disk must be partitioned to match the disk it is replacing before running the metareplace command. EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metasync(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D) Solaris Volume Manager Administration Guide SunOS 5.10 8 Aug 2003 metareplace(1M)