10 More Discussions You Might Find Interesting
1. Solaris
I have "inherited" a OmniOS (illumos based) server.
I noticed rsync is significantly slower in respect to my reference, FreeBSD 12-CURRENT, running on exactly same hardware.
Using same hardware, same command with same source and target disks, OmniOS r151026 gives:
test@omniosce:~# time... (11 Replies)
Discussion started by: priyadarshan
11 Replies
2. Solaris
Hi bros,
CPU speed of Sun Sparc Enterprise T5140 in data sheet is 1200 Mhz. Why it shows in "prtdiag -v" command each thread just has speed at 1165 Mhz.
Thank you,
tien86 (4 Replies)
Discussion started by: tien86
4 Replies
3. HP-UX
Hi everybody,
I have an application which displayes the process name and argument list for that each and every process running on the system.
For this purpose the application used the pstat_getproc() method which fetches the structure pst_status.
By this method we get the programm name up to 15... (0 Replies)
Discussion started by: sardesh3
0 Replies
4. Filesystems, Disks and Memory
I analysed disk performance with blktrace and get some data:
read:
8,3 4 2141 2.882115217 3342 Q R 195732187 + 32
8,3 4 2142 2.882116411 3342 G R 195732187 + 32
8,3 4 2144 2.882117647 3342 I R 195732187 + 32
8,3 4 2145 ... (1 Reply)
Discussion started by: W.C.C
1 Replies
5. Solaris
Please let me know if there is any way I can find out (either via command line or SMF) the following:
1.CPU model (eg. Pentium 4,Celeron)
2.CPU speed (eg. 1GHz)
for this I could get the output through psrinfo -v, but still is there any other way?
3.Hard disk model (eg. Seagate).
When I... (9 Replies)
Discussion started by: saagar
9 Replies
6. Linux
Need to find CPU Speed of zLinux.
The commands like cat /proc/cpuinfo and /usr/bin/cpufreq-info does not gave me the expected results.
/usr/bin/cpufreq-info prints the
....
analyzing CPU 0:
no or unknown cpufreq driver is active on this CPU
analyzing CPU 1:
no or unknown cpufreq... (1 Reply)
Discussion started by: surajb
1 Replies
7. HP-UX
Need to find the CPU speed of HP UX for a non root login.
echo "itick_per_usec/D" | adb /stand/vmunix /dev/mem | tail -1 will give the following for non root users
ERROR: cannot open `/dev/mem', errno = 13, Permission denied (2 Replies)
Discussion started by: surajb
2 Replies
8. HP-UX
How can I get the CPUs speed without root permissions?
Thanks. (2 Replies)
Discussion started by: psimoes79
2 Replies
9. UNIX for Dummies Questions & Answers
Hi,
Is there a command I can use to find out how many CPU's and what type are on my server? (I was told to use cat /proc/cpuinfo)
Also, how do I know what kind of bus speeds are on my server?
Thanks in advance:) (3 Replies)
Discussion started by: ihot
3 Replies
10. AIX
how do i determine the speed of a cpu on AIX 4.3.3 or 5.1? (5 Replies)
Discussion started by: csaunders
5 Replies
cfspeed(3C) cfspeed(3C)
NAME
cfgetospeed(), cfsetospeed(), cfgetispeed(), cfsetispeed() - tty baud rate functions
SYNOPSIS
DESCRIPTION
These functions set and get the input and output speed codes in the termios structure referenced by termios_p. The termios structure con-
tains these speed codes representing input and output baud rates as well as other terminal related parameters. Setting the parameters on a
terminal file does not become effective until is successfully called.
returns the output speed code from the
termios structure referenced by termios_p.
sets the output speed code in the
termios structure referenced by termios_p to speed. The speed code for a baud rate of zero, is used to termi-
nate the connection. If is specified, the modem control lines are no longer asserted, which normally discon-
nects the line.
returns the input speed code from the
termios structure referenced by termios_p.
sets the input speed code in the
termios structure referenced by termios_p to speed.
RETURN VALUE
returns the output speed code from the termios structure referenced by termios_p.
returns the input speed code from the termios structure referenced by termios_p.
and return zero upon successful completion. Otherwise, they return -1 and set to indicate the error.
ERRORS
and fail when the following condition is encountered:
[EINVAL] The value of speed is outside the range of possible speed codes as specified in
WARNINGS
and can be used to set speed codes in the termios structure that are not supported by the terminal hardware.
SEE ALSO
tcattribute(3C), thread_safety(5), termio(7).
STANDARDS CONFORMANCE
cfspeed(3C)