Continually looking for ways to save money without sacrificing performance? Hear how the ProLiant DL120 G5 SATA Rack Server delivers the latest in performance at an affordable cost
Hello everybody,
I need to connect a laptop 2.5 SATA hard drive to a Desktop board (which uses 3.5' SATA hard drives). I've tried the connectors and they fit excellent in the 2.5 SATA connectors.
The problem is that the laptop hard drive uses 5v and the PC's power source sends 12v. So, my... (4 Replies)
trying to setup a sata drive using a sata to scsi adaptor
I have a sata 1TB Deskstar that I had setup before and during shipment from a facilty to another, the disk failed. The handling was not great, lots of throwing boxes, etc. I have a new disk from Hitachi (thankyou Hitachi) anyway, I don't... (1 Reply)
Dear Sir,
I have one HP Proliant DL-380 G5 Server, i tried to install Redhat Enterprise Verison 4, when i am trying to install the linux operating system it is coming one error message your hard disk not found, we are using Serial Scsi harddisk 146 GB, array controller is p400.
i would... (1 Reply)
IBSWITCHES(8) OpenIB Diagnostics IBSWITCHES(8)NAME
IBSWITCHES - show InfiniBand switch nodes in topology
SYNOPSIS
ibswitches [options] [<topology-file>]
DESCRIPTION
ibswitches is a script which either walks the IB subnet topology or uses an already saved topology file and extracts the switch nodes.
OPTIONS -C, --Ca <ca_name> use the specified ca_name.
-P, --Port <ca_port> use the specified ca_port.
-t, --timeout <timeout_ms> override the default timeout for the solicited mads.
-h, --help show the usage message
--config, -z <config_file> Specify alternate config file.
Default: /etc/infiniband-diags/ibdiag.conf
Local port Selection
Multiple port/Multiple CA support: when no IB device or port is specified (see the "local umad parameters" below), the libibumad library
selects the port to use by the following criteria:
1. the first port that is ACTIVE.
2. if not found, the first port that is UP (physical link up).
If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and will fail if it is not possible.
For example:
ibaddr # use the first port (criteria #1 above)
ibaddr -C mthca1 # pick the best port from "mthca1" only.
ibaddr -P 2 # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2 # use the specified port only.
FILES
CONFIG FILE
/etc/infiniband-diags/ibdiag.conf
A global config file is provided to set some of the common options for all tools. See supplied config file for details.
NODE NAME MAP FILE FORMAT
The node name map is used to specify user friendly names for nodes in the output. GUIDs are used to perform the lookup.
This functionality is provided by the opensm-libs package. See opensm(8) for the file location for your installation.
Generically:
# comment
<guid> "<name>"
Example:
# IB1
# Line cards
0x0008f104003f125c "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f125d "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d2 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d3 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10bf "IB1 (Rack 11 slot 12 ) ISR9288/ISR9096 Voltaire sLB-24D"
# Spines
0x0008f10400400e2d "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2e "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2f "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e31 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e32 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB-12D"
# GUID Node Name
0x0008f10400411a08 "SW1 (Rack 3) ISR9024 Voltaire 9024D"
0x0008f10400411a28 "SW2 (Rack 3) ISR9024 Voltaire 9024D"
0x0008f10400411a34 "SW3 (Rack 3) ISR9024 Voltaire 9024D"
0x0008f104004119d0 "SW4 (Rack 3) ISR9024 Voltaire 9024D"
SEE ALSO ibnetdiscover(8)DEPENDENCIES
ibnetdiscover, ibnetdiscover format
AUTHOR
Hal Rosenstock
< halr@voltaire.com >
IBSWITCHES(8)