HP raid Controllers enabled but drives not detected


 
Thread Tools Search this Thread
Special Forums Hardware HP raid Controllers enabled but drives not detected
# 1  
Old 02-25-2011
HP raid Controllers enabled but drives not detected

I'm getting this message using hpacucli in HP ProLiant BL460c G6. Raid controller is already enabled:

Code:
[root@csadmin21 ~]# hpacucli

HP Array Configuration Utility CLI 8.35-7.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.

=> ctrl all show config
 
Smart Array P410i in Slot 0 (Embedded)    (sn: 5001438008B0ADE0)

=> ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

Error: Cannot create array. Cannot add physical drive 1I:1:1

=> ctrl all show status

Smart Array P410i in Slot 0 (Embedded)

   Controller Status: Not OK
   Cache Status: Permanently Disabled
   Battery/Capacitor Status: Recharging

=> ctrl slot=0 ld all show

Error: The specified device does not have any logical drives.

=> ctrl slot=0 pd all show

Error: The specified controller does not have any physical drives on it.

Any ideas why i'm getting this error message ?

Last edited by pludi; 02-25-2011 at 04:16 AM..
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

2. BSD

FreeBSD and realtek wifi controllers...?

Hi. I have been running OpenBSD(4.9) and it recognizes my Belkin wireless adapter and I don't have issues with it very often. I prefer FreeBSD over OpenBSD, but FreeBSD(7.4) doesnt recognize my USB wifi card. Under OpenBSD ifconfig shows my card as rsu0 so I tried adding the following to... (1 Reply)
Discussion started by: bsdforme
1 Replies

3. Solaris

Different disk size on different controllers

Hi folks, I just recently build myself a NAS with Oracle Solaris 11 Express. MOBO: Asus M4N68T-M LE V2 nForce 630a AM3 PCI-e Controller: 2x Exsys EX-3503 with Sil3132 Chipset (latest FW) HDD: 7x 2000GB Samsung EcoGreen F4 HD204UI 32MB 3.5" (latest FW) OS: SunOS zaruba 5.11 snv_151a i86pc... (4 Replies)
Discussion started by: Garter
4 Replies

4. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

5. Solaris

Why do controllers differ between physical and logical names

When I look at format I can see the following info: AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424> /pci@1c,600000/scsi@2/sd@0,0 1. c1t1d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424> /pci@1c,600000/scsi@2/sd@1,0 Can anyone tell me... (2 Replies)
Discussion started by: James_UK
2 Replies

6. Solaris

Need description on System Controllers

Hi , I am new into solaris , need to know what a system Controller is , what it exactly does. Is it available in all Sun boxes or only on High end servers. Is it similar to the Linux console in AIX boxes . Thanks !!! (7 Replies)
Discussion started by: mpics66
7 Replies

7. UNIX and Linux Applications

HSZ70 controllers and formatting disks

Hi I am trying to format all the disks in several of my old dec-alphas and unix boxes. I have connected to the hsz70 controller and used "run hsutil" command but when i select the "format" option, the response i get is "no available unattached devices to format" Does anyone know how I can... (0 Replies)
Discussion started by: petergrivas
0 Replies

8. Shell Programming and Scripting

how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX

hi how floppy disks, CDs and flash drives (pen drives) are accessed in UNIX? thanks (0 Replies)
Discussion started by: nokia1100
0 Replies

9. UNIX for Dummies Questions & Answers

command to know disk controllers in a machine

Hi!! I am these days working on a project, where I need to know about the disk controllers available in a machine (e.g., 3ware,IBM,etc). Please, let me know the command by which I can get the information. thnx, priyanka (3 Replies)
Discussion started by: reply2priyanka
3 Replies
Login or Register to Ask a Question
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)