RFID Pill Monitors Body Temperature at Walking Race


 
Thread Tools Search this Thread
Special Forums News, Links, Events and Announcements Complex Event Processing RSS News RFID Pill Monitors Body Temperature at Walking Race
# 1  
Old 08-07-2008
RFID Pill Monitors Body Temperature at Walking Race

by Brian Albright, RFID Update Researchers at Radboud University in The Netherlands were able to monitor the body temperature of participants at the world’s largest marching event using RFID technology. Volunteer participants in the annual Four Days Marches of Nijmegen swallowed an RFID-based temperature sensor that measured their internal temperature and helped researchers identify potential [...]

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

5 More Discussions You Might Find Interesting

1. AIX

AIX native SNMP producing limited results when walking MIB tree

The company I work for has various AIX servers that I've recently migrated to AIX 7.1 (from 6.1). Some are powerHA clusters some are not. Likewise, the systems engineer that I replaced had net-snmp installed on said clustered systems. Long story short I am re-invoking AIX's native SNMP (v3) for... (1 Reply)
Discussion started by: davix
1 Replies

2. UNIX for Dummies Questions & Answers

ksh - walking back up a directory PATH

Hi there, I am putting a script together to apply a label to a directory structure but it can't be done down the directory structure, i must start at the end and work back and this is what i am struggling with. for example, i will supply a path as an argument to a script, e.g ... (11 Replies)
Discussion started by: surfbus78
11 Replies

3. SCO

SCO connected Monitors

Hi all, we have 5 monitors connected to a SCO server using it's IP address(192.168.1.1), the server got busted, we have another similar server to connect the monitors to , how can i change the IP address of the new server to be (192.168.1.1), and connect the monitors to it. thanks, Marcel (1 Reply)
Discussion started by: marcelious
1 Replies

4. BSD

Two monitors

Hello!:) There is the following situation: I've got video Ti 4200 on FreeBSD 5.1 and two monitors connected to it, how can I make available the second monitor in CLI and GUI. Thanks! (0 Replies)
Discussion started by: kamazi
0 Replies

5. UNIX for Dummies Questions & Answers

Monitors in Linux

Dear Experts How can I change the monitor specifications, specially type, Frequency and resolution in linux Redhat 9 or more??? after the linux installation. Please advise Thanks (3 Replies)
Discussion started by: Reza Nazarian
3 Replies
Login or Register to Ask a Question
OCF_PACEMAKER_HEALTH(7) 				      Pacemaker Configuration					   OCF_PACEMAKER_HEALTH(7)

NAME
ocf_pacemaker_HealthSMART - SMART health status SYNOPSIS
OCF_RESKEY_state=string OCF_RESKEY_drives=string OCF_RESKEY_temp_lower_limit=string OCF_RESKEY_temp_upper_limit=string HealthSMART [start | stop | monitor | meta-data | validate-all] DESCRIPTION
Systhem health agent that checks the S.M.A.R.T. status of the given drives and updates the #health-smart attribute. SUPPORTED PARAMETERS
OCF_RESKEY_state = string [/var/run//health-smart-{OCF_RESOURCE_INSTANCE}.state] State file Location to store the resource state in. OCF_RESKEY_drives = string [sda] Drives to check The drives to check as a SPACE separated list. Enter only the part after the "/dev/" i.e. "sda". At the moment /dev/sda is hard coded. Sorry. OCF_RESKEY_temp_lower_limit = string [0] Lower limit for the temperature of the drive(s) Lower limit of the temperature in deg C of the drive(s). Below this limit there status will be red. The yellow limit is 5 deg C more than this value. OCF_RESKEY_temp_upper_limit = string [60] Upper limit for red smart attribute Upper limit of the temperature if deg C of the drives(s). If the drive reports a temperature higher than this value the status of #health-smart will be red. The yellow limit is 5 deg C below this value. AUTHOR
Andrew Beekhof <andrew@beekhof.net> Author. Pacemaker Configuration 07/05/2010 OCF_PACEMAKER_HEALTH(7)