RFID Pill Monitors Body Temperature at Walking Race


 
Thread Tools Search this Thread
Special Forums News, Links, Events and Announcements Complex Event Processing RSS News RFID Pill Monitors Body Temperature at Walking Race
# 1  
Old 08-07-2008
RFID Pill Monitors Body Temperature at Walking Race

by Brian Albright, RFID Update Researchers at Radboud University in The Netherlands were able to monitor the body temperature of participants at the world’s largest marching event using RFID technology. Volunteer participants in the annual Four Days Marches of Nijmegen swallowed an RFID-based temperature sensor that measured their internal temperature and helped researchers identify potential [...]

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

5 More Discussions You Might Find Interesting

1. AIX

AIX native SNMP producing limited results when walking MIB tree

The company I work for has various AIX servers that I've recently migrated to AIX 7.1 (from 6.1). Some are powerHA clusters some are not. Likewise, the systems engineer that I replaced had net-snmp installed on said clustered systems. Long story short I am re-invoking AIX's native SNMP (v3) for... (1 Reply)
Discussion started by: davix
1 Replies

2. UNIX for Dummies Questions & Answers

ksh - walking back up a directory PATH

Hi there, I am putting a script together to apply a label to a directory structure but it can't be done down the directory structure, i must start at the end and work back and this is what i am struggling with. for example, i will supply a path as an argument to a script, e.g ... (11 Replies)
Discussion started by: surfbus78
11 Replies

3. SCO

SCO connected Monitors

Hi all, we have 5 monitors connected to a SCO server using it's IP address(192.168.1.1), the server got busted, we have another similar server to connect the monitors to , how can i change the IP address of the new server to be (192.168.1.1), and connect the monitors to it. thanks, Marcel (1 Reply)
Discussion started by: marcelious
1 Replies

4. BSD

Two monitors

Hello!:) There is the following situation: I've got video Ti 4200 on FreeBSD 5.1 and two monitors connected to it, how can I make available the second monitor in CLI and GUI. Thanks! (0 Replies)
Discussion started by: kamazi
0 Replies

5. UNIX for Dummies Questions & Answers

Monitors in Linux

Dear Experts How can I change the monitor specifications, specially type, Frequency and resolution in linux Redhat 9 or more??? after the linux installation. Please advise Thanks (3 Replies)
Discussion started by: Reza Nazarian
3 Replies
Login or Register to Ask a Question
ACPI_THERMAL(4) 					   BSD Kernel Interfaces Manual 					   ACPI_THERMAL(4)

NAME
acpi_thermal -- ACPI thermal management subsystem SYNOPSIS
device acpi DESCRIPTION
The acpi_thermal driver provides the thermal management features of the ACPI module. This driver has a sysctl(8) interface and a devd(8) notification interface. The sysctls export properties of each ACPI thermal zone object. There can be multiple thermal zones in a system. For example, each CPU and the enclosure could all be separate thermal zones, each with its own setpoints and cooling devices. Thermal zones are numbered sequentially in the order they appear in the AML. The acpi_thermal driver also activates the active cooling system according to each thermal zone's setpoints. SYSCTL VARIABLES
hw.acpi.thermal.min_runtime Number of seconds to continue active cooling once started. A new active cooling level will not be selected until this interval expires. hw.acpi.thermal.polling_rate Number of seconds between polling the current temperature. hw.acpi.thermal.user_override If set to 1, allow user override of various setpoints (below). The original values for these settings are obtained from the BIOS and system overheating and possible damage could occur if changed. Default is 0 (no override). hw.acpi.thermal.tz%d.active Current active cooling system state. If this is non-negative, the appropriate _AC%d object is running. Set this value to the desired active cooling level to force the corresponding fan object to the appropriate level. hw.acpi.thermal.tz%d.passive_cooling If set to 1, passive cooling is enabled. It does cooling without fans using cpufreq(4) as the mechanism for controlling CPU speed. Default is enabled for tz0 where it is available. hw.acpi.thermal.tz%d.thermal_flags Current thermal zone status. These are bit-masked values. hw.acpi.thermal.tz%d.temperature Current temperature for this zone. hw.acpi.thermal.tz%d._PSV Temperature to start passive cooling by throttling down CPU, etc. This value can be overridden by the user. hw.acpi.thermal.tz%d._HOT Temperature to start critical suspend to disk (S4). This value can be overridden by the user. hw.acpi.thermal.tz%d._CRT Temperature to start critical shutdown (S5). This value can be overridden by the user. hw.acpi.thermal.tz%d._ACx Temperatures at which to switch to the corresponding active cooling level. The lower the _ACx value, the higher the cooling power. All temperatures are printed in Celsius. Values can be set in Celsius (by providing a trailing "C") or Kelvin (by leaving off any trailing letter). When setting a value by sysctl(8), do not specify a trailing decimal (i.e., 90C instead of 90.0C). NOTIFIES
Notifies are passed to userland via devd(8). See /etc/devd.conf and devd.conf(5) for examples. The acpi_thermal driver sends events with the following attributes: system ACPI subsystem Thermal type The fully qualified thermal zone object path as in the ASL. notify An integer designating the event: 0x80 Current temperature has changed. 0x81 One or more trip points (_ACx, _PSV) have changed. 0x82 One or more device lists (_ALx, _PSL, _TZD) have changed. 0xcc Non-standard notify that the system will shutdown if the temperature stays above _CRT or _HOT for one more poll cycle. SEE ALSO
acpi(4), cpufreq(4), acpidump(8) AUTHORS
Michael Smith This manual page was written by Takanori Watanabe. BSD
March 17, 2007 BSD