7028-6C4 with an attached 7311-D20


 
Thread Tools Search this Thread
Operating Systems AIX 7028-6C4 with an attached 7311-D20
# 1  
Old 05-02-2008
7028-6C4 with an attached 7311-D20

A remote office that I support has a 7028-6C4 with an attached 7311-D20. Over a year ago the 7311-D20 power supply failed. We called IBM and found out it was no longer under maintenance but that the 7028-6C4 was. To get the 7311-D20 back under maintenance would cost more than that office wanted to spend.

Of course the 7028-6C4 keeps giving me the message:

"WARNING!!! The system is now operating with a power problem. This message will be walled every 12 hours. Remove this crontab entry after the problem is resolved."

This is unsettling for any user who logs in.

Travel dollars are non-existent so I can't travel there. Here is my question:

Is there a way to remove the 7311-D20 from the configuration so the 7028-6C4 no longer knows it there?
# 2  
Old 05-02-2008
Disconnect it from the 7028!

If the 7311 was bought in the first place then there must be some required resources in it, so disconnecting it and throwing it away is probably not an option.

As long as it is connected, the system will detect it on boot so it will checkout the resources and find the dead PSU.

In the D20 the second PSU is an option, it is not required, so you can just replace it with a blank.

What are the details of the problem / error and or diagnostic results? Are you sure the PSU has failed?

Are both D20 PSU's pugged in, or did the cleaner unplug one to plug in the hoover?...seen it many times.

Option 2:
Write a script and put it in a cron job to clear the wall rc.powerfail message from cron.
The diagela cron job usualy runs at 04:00, so at 04:01 run a job / script to remove the entry...but then you won't know if another power problem happens, then again would you anyway if you always get the message for the D20 walled.

Option 3:
Get in before they do and run diags, if all is OK (apart from the D20 PSU) remove the wall cron job.

Option 4:
Buy a PSU or a blanking plate from ebay / IBM reseller / IBM part sales and talk a person on site through replacing it. This is probably the cheapest option and all the info you and they need is on the web / in the service books - and they are hot swap:

http://publib16.boulder.ibm.com/pser...pdf/380627.pdf

Page 150 would be worth a read.

Page 168 gives the part (fru) numbers for the PSU and the dummy PSU filler.

A web search for IBM part sales should give you plenty of places to ask about prices.
# 3  
Old 05-05-2008
Thank you for the response. Your reference to the D20 Service pdf was particularly valuable.

I was able to find an associate that works within a few miles of the location who will remove the D20 for me. We have already relocated two hard disks from the D20 to the 7028. Once all of this is done I will be able to migrate the data and functions from an F50 and a P620 to the 7028, then shut down those boxes.
# 4  
Old 05-05-2008
are you sure you don't have a power problem with the server? Does diags run clean?

work with someone onsite to remove the cables to the I/O drawer. Of course remove the devices first.
Login or Register to Ask a Question

Previous Thread | Next Thread

8 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Getting the Attached File in Email

Hi All, Is there a way on how to get the attached file in email using shell script? what i'm going to do? all i can see is to send and email but to get an attached file in email i don't find it. Please advise, Thanks, (4 Replies)
Discussion started by: znesotomayor
4 Replies

2. Shell Programming and Scripting

Mailx attachment not getting attached.

Hi Friends, Please help me with this problem. I have a number of split files in a directory. each split files has pdf filenames in it. pdf files are also in the same directory. I send a mail for each split files present in the directory with the pdf file mentioned in the file. I have... (4 Replies)
Discussion started by: jcebalaji
4 Replies

3. AIX

max drive size for 7028 p Series

We have an eight year old IBM P series 7028 model server running AIX 5.2, and are thinking about installing some bigger drives. The current ones are 78GB in a RAID5 array. It looks like there are 146 and 300GB drives available. Just wondering what a realistic size drive to install would be that... (3 Replies)
Discussion started by: markper
3 Replies

4. Shell Programming and Scripting

multiple files to be attached

Hi all, Am in need of attaching multiple files of similar pattern? For example the files like a1.txt b1.txt c1.txt can be reffered as *1.txt Can anyone help me in attaching the files of similar pattern without mentioning their names completely. (3 Replies)
Discussion started by: Sindhuap
3 Replies

5. Solaris

new attached lun in solaris 10

hi, what are the steps to detect and configure a new attached lun in Solaris 10. Is there any difference between cfgadm and luxadm command ? rgds, snjksh (5 Replies)
Discussion started by: snjksh
5 Replies

6. Shell Programming and Scripting

Process not attached to terminal

Hi Folks, When i try to run schedule job on Unix server am getting following errror messges in logs pic_selection @starting on Fri Feb 5 01:53:06 GMT 2010 ------------------------------------------------------------------------------- Microfocus Cobol batch run Started: Fri Feb 5... (4 Replies)
Discussion started by: bhargav20
4 Replies

7. Shell Programming and Scripting

How to get number of attached hard disks in HP-UX

how do i get the number of attached hard disks in HP-UX (1 Reply)
Discussion started by: achak01
1 Replies

8. UNIX for Dummies Questions & Answers

i/o drawer 7311-D20

can anyone help me with the i/o drawer D20???? what firmware i need for this machine and how do i install it? (0 Replies)
Discussion started by: amitt74
0 Replies
Login or Register to Ask a Question