SCSI Disks


 
Thread Tools Search this Thread
Operating Systems AIX SCSI Disks
# 1  
Old 07-27-2006
SCSI Disks

Hi

Is it possible to install in p5 and pSeries SCSI Disks from SUN on DELL? Will they work?

Regards,
Pit
Login or Register to Ask a Question

Previous Thread | Next Thread

8 More Discussions You Might Find Interesting

1. Solaris

Modifying properties to use scsi-3 reservation for disks with two paths in sun cluster

Hi I am having two node cluster. I was trying to change the to use scsi3 reservation for all disks having two paths. Please let me know where I went wrong or there any issue to implement the same. On node1 bash-3.2# cldev status === Cluster DID Devices === Device Instance ... (8 Replies)
Discussion started by: sb200
8 Replies

2. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

3. Red Hat

Finding scsi id

Hi, I would like to know scsi id of hard drive, which command is used to find scsi id of hard drive and disk related information. Regards Manoj (3 Replies)
Discussion started by: manoj.solaris
3 Replies

4. UNIX for Dummies Questions & Answers

SCSI Harddisk

hey guys this is my problem I have SCO unix installed on a IDE h/drive. I want to add a SCSI hard drive, how do i do that within UNIX (1 Reply)
Discussion started by: kwame.neilsen
1 Replies

5. Solaris

Help probe-scsi-all

I have run init 0 to bring it to OK prompt. I know that probe-scsi-all can hang the system. I want to know what is the difference between probe-scsi-all and probe-scsi. I was told that probe-scsi-all external and internal devices and probe-scsi shows only internal devices. what dose this ... (3 Replies)
Discussion started by: nitinkgoud
3 Replies

6. UNIX for Advanced & Expert Users

Scsi

I would like to install a AIT drive to the scsi connector on our solaris box. I am very new to the unix world and would be greatful if someone could help or lead me in the right direction. Thanks (4 Replies)
Discussion started by: vpyle
4 Replies

7. UNIX for Dummies Questions & Answers

The difference between SCSI & IDE Hard disks.

Hello agian ! What is the difference between SCSI and IDE hard disks ? I have Intel PC and when i check i have Generic IDE TYPE DISK0 is IDE hard disk is ok for Solrais ? or should i buy the SCSI hard disk ? Thanks Abid Malik (3 Replies)
Discussion started by: abidmalik
3 Replies

8. UNIX for Advanced & Expert Users

Scsi

How can you get a scsi card to initalize or decome available at boot up on AIX 4.3 (1 Reply)
Discussion started by: truma1
1 Replies
Login or Register to Ask a Question
vparutil(1M)															      vparutil(1M)

NAME
vparutil - get and set SCSI parameters for SCSI controllers from a virtual partition SYNOPSIS
dev_path dev_path dev_path scsi_id] scsi_rate] DESCRIPTION
The command gets and sets SCSI parameters for SCSI controllers within a running virtual partition. When setting the SCSI parameters using the option, the virtual partition which owns the specified SCSI controller must be in the down state. If not, the command will fail with the appropriate error code. The SCSI parameters for a given SCSI controller must first be set (from the firmware BCH prompt or using the option) before the parameters can be retrieved using the option. The command is allowed on Itanium(R)-based platforms for compatibility. No action is taken for the command. Options recognizes the following command-line options: Deletes an entry for the specified SCSI controller at dev_path from the SCSI table. Gets the SCSI parameters for the specified SCSI controller at dev_path. Sets the SCSI parameters for the specified SCSI controller at dev_path. Operands recognizes the following command-line operands: dev_path The device path of the SCSI controller. id The SCSI ID for the specified controller (defaults to 7). rate The SCSI rate for the specified controller. This parameter can have one of two values: for the corresponding fast wide and ultra wide SCSI interfaces. Note For managing SCSI controllers, use corresponding SCSI utilities. For further information refer to SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser. When virtual partition flexible administrative capability is enabled, only a Designated-Admin vPar can set SCSI parameters for SCSI con- trollers. EXAMPLES
Set the SCSI ID for controller at 0/0/2/0 to 3 with the fast wide rate: RETURN VALUE
Successful. Invalid SCSI controller specification. Invalid SCSI ID. Could not communicate with virtual partition monitor. Virtual partition which owns SCSI controller is not in down state. Internal firmware call failed. Other error. AUTHOR
was developed by the Hewlett-Packard Company. SEE ALSO